{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,27]],"date-time":"2026-07-27T11:56:34Z","timestamp":1785153394320,"version":"3.55.0"},"reference-count":16,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2012,8,1]],"date-time":"2012-08-01T00:00:00Z","timestamp":1343779200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2012,8,1]],"date-time":"2012-08-01T00:00:00Z","timestamp":1343779200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["ajkd.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Kidney Diseases"],"published-print":{"date-parts":[[2012,8]]},"DOI":"10.1053\/j.ajkd.2012.01.021","type":"journal-article","created":{"date-parts":[[2012,4,11]],"date-time":"2012-04-11T09:46:04Z","timestamp":1334137564000},"page":"272-279","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":64,"title":["A Randomized Trial of Catheters of Different Lengths to Achieve Right Atrium Versus Superior Vena Cava Placement for Continuous Renal Replacement Therapy"],"prefix":"10.1053","volume":"60","clinical-trial-number":[{"clinical-trial-number":"actrn12611000759998","registry":"10.18810\/anzctr"}],"author":[{"given":"David","family":"Morgan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kwok","family":"Ho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Conor","family":"Murray","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hugh","family":"Davies","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeanne","family":"Louw","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"5","key":"10.1053\/j.ajkd.2012.01.021_bib1","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1097\/01.RVI.0000071097.76348.72","article-title":"Central venous catheter tip position: a continuing controversy","volume":"14","author":"Vesely","year":"2003","journal-title":"J Vasc Interv Radiol"},{"issue":"1","key":"10.1053\/j.ajkd.2012.01.021_bib2","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.bpa.2003.09.010","article-title":"Vascular access for dialysis in the intensive care unit","volume":"18","author":"Canaud","year":"2004","journal-title":"Best Pract Res Clin Anaesthesiol"},{"issue":"6","key":"10.1053\/j.ajkd.2012.01.021_bib3","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1046\/j.1525-139x.2001.00106.x","article-title":"Catheter performance","volume":"14","author":"Depner","year":"2001","journal-title":"Semin Dial"},{"issue":"3","key":"10.1053\/j.ajkd.2012.01.021_bib4","doi-asserted-by":"crossref","first-page":"220","DOI":"10.5414\/CNP72220","article-title":"Cardiac tamponade following insertion of an internal jugular vein catheter for hemodialysis","volume":"72","author":"Lee","year":"2009","journal-title":"Clin Nephrol"},{"issue":"8","key":"10.1053\/j.ajkd.2012.01.021_bib5","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.1093\/ndt\/12.8.1689","article-title":"Central venous catheters for haemodialysis: looking for optimal blood flow","volume":"12","author":"Jean","year":"1997","journal-title":"Nephrol Dial Transplant"},{"issue":"3","key":"10.1053\/j.ajkd.2012.01.021_bib6","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1177\/112972980100200304","article-title":"Factors influencing permanent catheter performance","volume":"2","author":"Mandolfo","year":"2001","journal-title":"J Vasc Access"},{"issue":"9 Pt 2","key":"10.1053\/j.ajkd.2012.01.021_bib7","doi-asserted-by":"crossref","first-page":"S443","DOI":"10.1097\/01.RVI.0000094617.61428.bc","article-title":"Reporting standards for central venous access","volume":"14","author":"Silberzweig","year":"2003","journal-title":"J Vasc Interv Radiol"},{"issue":"1","key":"10.1053\/j.ajkd.2012.01.021_bib8","first-page":"S1","article-title":"KDOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates: Hemodialysis Adequacy, Peritoneal Dialysis Adequacy and Vascular Access","volume":"48","year":"2006","journal-title":"Am J Kidney Dis"},{"issue":"5","key":"10.1053\/j.ajkd.2012.01.021_bib9","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1093\/ndt\/15.5.719","article-title":"Unsuspected cardiac tamponade following insertion of a haemodialysis catheter: a normal chest radiograph does not exclude a complication","volume":"15","author":"Ho","year":"2000","journal-title":"Nephrol Dial Transplant"},{"issue":"1","key":"10.1053\/j.ajkd.2012.01.021_bib10","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1177\/112972980800900113","article-title":"Dialysis catheter associated cardiac tamponade: quick diagnosis by extemporaneous echocardiography","volume":"9","author":"Ervo","year":"2008","journal-title":"J Vasc Access"},{"issue":"3","key":"10.1053\/j.ajkd.2012.01.021_bib11","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1007\/s00134-006-0507-9","article-title":"Vascular erosion by central venous catheters used for total parenteral nutrition","volume":"33","author":"Walshe","year":"2007","journal-title":"Intensive Care Med"},{"issue":"1","key":"10.1053\/j.ajkd.2012.01.021_bib12","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1177\/0310057X0803600106","article-title":"The incidence and risk of central venous catheter malpositioning: a prospective cohort study in 1619 patients","volume":"36","author":"Pikwer","year":"2008","journal-title":"Anaesth Intensive Care"},{"issue":"9","key":"10.1053\/j.ajkd.2012.01.021_bib13","doi-asserted-by":"crossref","first-page":"1563","DOI":"10.1007\/s00134-007-0754-4","article-title":"Continuous renal replacement therapy: a worldwide practice survey","volume":"33","year":"2007","journal-title":"Intensive Care Med."},{"issue":"4","key":"10.1053\/j.ajkd.2012.01.021_bib14","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.1097\/CCM.0b013e3181d454b3","article-title":"Catheter dysfunction and dialysis performance according to vascular access among 736 critically ill adults requiring renal replacement therapy: a randomized controlled study","volume":"38","author":"Parienti","year":"2010","journal-title":"Crit Care Med"},{"issue":"3","key":"10.1053\/j.ajkd.2012.01.021_bib15","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1378\/chest.07-2687","article-title":"Is traditional reading of the bedside chest radiograph appropriate to detect intraatrial central venous catheter position?","volume":"134","author":"Wirsing","year":"2008","journal-title":"Chest"},{"issue":"6","key":"10.1053\/j.ajkd.2012.01.021_bib16","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1111\/j.1399-6576.2006.01025.x","article-title":"Comparison of radiographic landmarks and the echocardiographic SVC\/RA junction in the positioning of long-term central venous catheters","volume":"50","author":"Hsu","year":"2006","journal-title":"Acta Anaesthesiol Scand"}],"container-title":["American Journal of Kidney Diseases"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S027263861200529X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S027263861200529X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T01:58:10Z","timestamp":1759456690000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S027263861200529X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,8]]},"references-count":16,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2012,8]]}},"alternative-id":["S027263861200529X"],"URL":"https:\/\/doi.org\/10.1053\/j.ajkd.2012.01.021","relation":{},"ISSN":["0272-6386"],"issn-type":[{"value":"0272-6386","type":"print"}],"subject":[],"published":{"date-parts":[[2012,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A Randomized Trial of Catheters of Different Lengths to Achieve Right Atrium Versus Superior Vena Cava Placement for Continuous Renal Replacement Therapy","name":"articletitle","label":"Article Title"},{"value":"American Journal of Kidney Diseases","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1053\/j.ajkd.2012.01.021","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2012 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}