{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T05:10:09Z","timestamp":1761023409138,"version":"build-2065373602"},"reference-count":18,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2008,11,1]],"date-time":"2008-11-01T00:00:00Z","timestamp":1225497600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2008,11,1]],"date-time":"2008-11-01T00:00:00Z","timestamp":1225497600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jfas.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Foot and Ankle Surgery"],"published-print":{"date-parts":[[2008,11]]},"DOI":"10.1053\/j.jfas.2008.06.009","type":"journal-article","created":{"date-parts":[[2008,10,29]],"date-time":"2008-10-29T04:14:01Z","timestamp":1225253641000},"page":"598-602","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"title":["Percutaneous Contoured Locking Plate Fixation of the Pilon Fracture: Surgical Technique"],"prefix":"10.1053","volume":"47","author":[{"given":"Thomas","family":"Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neal M.","family":"Blitz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shannon M.","family":"Rush","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"3","key":"10.1053\/j.jfas.2008.06.009_bib1","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/00005131-200103000-00002","article-title":"Surgical options for the treatment of severe tibial pilon fractures: a study of three techniques","volume":"15","author":"Blauth","year":"2001","journal-title":"J Orthop Trauma"},{"issue":"supp II","key":"10.1053\/j.jfas.2008.06.009_bib2","first-page":"173","article-title":"A comparison of treatment methods for pilon fractures","volume":"86-B","author":"Koulouvaris","year":"2004","journal-title":"J Bone Joint Surg Br"},{"key":"10.1053\/j.jfas.2008.06.009_bib3","article-title":"Minimally invasive treatment of pilon fractures with a low profile plate: preliminary results in 17 cases","author":"Borens","year":"2006","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1053\/j.jfas.2008.06.009_bib4","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/S0020-1383(69)80066-5","article-title":"Fractures of the lower end of the tibia into the ankle joint","volume":"1","author":"Allgower","year":"1969","journal-title":"Injury"},{"key":"10.1053\/j.jfas.2008.06.009_bib5","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1097\/00003086-200006000-00010","article-title":"Pilon fractures","volume":"375","author":"Watson","year":"2000","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"10.1053\/j.jfas.2008.06.009_bib6","doi-asserted-by":"crossref","first-page":"937","DOI":"10.1097\/00005373-199911000-00022","article-title":"Tibial pilon fractures: A comparison of treatment methods","volume":"47","author":"Pugh","year":"1999","journal-title":"J Trauma"},{"issue":"6","key":"10.1053\/j.jfas.2008.06.009_bib7","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1302\/0301-620X.86B6.15077","article-title":"Intra-articular fractures of the tibial plafond","volume":"86","author":"Okcu","year":"2004","journal-title":"J Bone Joint Surg Br"},{"issue":"5","key":"10.1053\/j.jfas.2008.06.009_bib8","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1097\/01.ta.0000188936.79798.4e","article-title":"Distal metaphyseal fractures of tibia: a prospective randomized trial of closed reduction and intramedullary nail versus open reduction and plate and screws fixation","volume":"59","author":"Im","year":"2005","journal-title":"J Trauma"},{"key":"10.1053\/j.jfas.2008.06.009_bib9","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1097\/00003086-199708000-00016","article-title":"Results of surgical treatment of tibial plafond fractures","volume":"341","author":"Babis","year":"1997","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2008.06.009_bib10","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1097\/00003086-199307000-00013","article-title":"Open reduction and internal fixation of tibial plafond fractures: Variables contributing to poor results and complications","volume":"292","author":"Teeny","year":"1993","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"10.1053\/j.jfas.2008.06.009_bib11","doi-asserted-by":"crossref","first-page":"S32","DOI":"10.1097\/00005131-199902000-00002","article-title":"A staged protocol for soft tissue management in the treatment of complex pilon fractures","volume":"13","author":"Sirkin","year":"1999","journal-title":"J Orthop Trauma"},{"key":"10.1053\/j.jfas.2008.06.009_bib12","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/S0020-1383(01)00163-2","article-title":"High energy plafond fractures treated by a spanning external fixator initially and followed by a second stage open reduction internal fixation of the articular surface-preliminary report","volume":"32","author":"Dickson","year":"2001","journal-title":"Injury"},{"issue":"12","key":"10.1053\/j.jfas.2008.06.009_bib13","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1097\/00005373-198612000-00011","article-title":"Delayed wound healing, infection, and nonunion following open reduction and internal fixation of tibial plafond fractures","volume":"26","author":"Dillin","year":"1986","journal-title":"J Trauma"},{"issue":"2","key":"10.1053\/j.jfas.2008.06.009_bib14","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1097\/00005131-199902000-00004","article-title":"Early outcome of hybrid external fixation for fracture of the distal tibia","volume":"13","author":"Anglen","year":"1999","journal-title":"J Orthop Trauma"},{"issue":"11","key":"10.1053\/j.jfas.2008.06.009_bib15","doi-asserted-by":"crossref","first-page":"1646","DOI":"10.2106\/00004623-199611000-00003","article-title":"Operative treatment of fractures of the tibial plafond","volume":"78","author":"Wyrsch","year":"1996","journal-title":"J Bone Joint Surg Am"},{"issue":"8","key":"10.1053\/j.jfas.2008.06.009_bib16","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1097\/00005131-200409000-00003","article-title":"Biomechanics of locked plates and screws","volume":"18","author":"Egol","year":"2004","journal-title":"J Orthop Trauma"},{"issue":"3","key":"10.1053\/j.jfas.2008.06.009_bib17","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1007\/s00264-004-0541-6","article-title":"Percutaneous plating of distal tibial fractures","volume":"28","author":"Maffulli","year":"2004","journal-title":"Int Orthop"},{"issue":"4","key":"10.1053\/j.jfas.2008.06.009_bib18","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1053\/j.jfas.2007.05.002","article-title":"Tibial plafond fractures: Limited incision reduction with percutaneous fixation","volume":"46","author":"Salton","year":"2007","journal-title":"J Foot Ankle Surg"}],"container-title":["The Journal of Foot and Ankle Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S106725160800286X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S106725160800286X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T04:51:48Z","timestamp":1761022308000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S106725160800286X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,11]]},"references-count":18,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2008,11]]}},"alternative-id":["S106725160800286X"],"URL":"https:\/\/doi.org\/10.1053\/j.jfas.2008.06.009","relation":{},"ISSN":["1067-2516"],"issn-type":[{"type":"print","value":"1067-2516"}],"subject":[],"published":{"date-parts":[[2008,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Percutaneous Contoured Locking Plate Fixation of the Pilon Fracture: Surgical Technique","name":"articletitle","label":"Article Title"},{"value":"The Journal of Foot and Ankle Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1053\/j.jfas.2008.06.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2008 American College of Foot and Ankle Surgeons. Published by Elsevier Ltd. on behalf of the American College of Foot and Ankle Surgeons All rights reserved.","name":"copyright","label":"Copyright"}]}}