{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T07:46:41Z","timestamp":1781596001364,"version":"3.54.5"},"reference-count":26,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2015,7,1]],"date-time":"2015-07-01T00:00:00Z","timestamp":1435708800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,7,1]],"date-time":"2015-07-01T00:00:00Z","timestamp":1435708800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jfas.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Foot and Ankle Surgery"],"published-print":{"date-parts":[[2015,7]]},"DOI":"10.1053\/j.jfas.2015.03.014","type":"journal-article","created":{"date-parts":[[2015,5,8]],"date-time":"2015-05-08T03:31:28Z","timestamp":1431055888000},"page":"657-662","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":31,"title":["Bioabsorbable Versus Metallic Screw Fixation for Tibiofibular Syndesmotic Ruptures: A Meta-Analysis"],"prefix":"10.1053","volume":"54","author":[{"given":"Dorien M.","family":"van der Eng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niels W.L.","family":"Schep","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tim","family":"Schepers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1053\/j.jfas.2015.03.014_bib1","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1016\/j.injury.2013.09.035","article-title":"Technical aspects of the syndesmotic screw and their effect on functional outcome following acute distal tibiofibular syndesmosis injury","volume":"45","author":"Schepers","year":"2014","journal-title":"Injury"},{"key":"10.1053\/j.jfas.2015.03.014_bib2","doi-asserted-by":"crossref","first-page":"1880","DOI":"10.1016\/j.injury.2013.08.011","article-title":"Functional outcomes following syndesmotic fixation: a comparison of screws retained in situ versus routine removal\u2014is it really necessary?","volume":"44","author":"Tucker","year":"2013","journal-title":"Injury"},{"key":"10.1053\/j.jfas.2015.03.014_bib3","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.injury.2007.11.425","article-title":"Operative aspects of the syndesmotic screw: review of current concepts","volume":"39","author":"van den Bekerom","year":"2008","journal-title":"Injury"},{"key":"10.1053\/j.jfas.2015.03.014_bib4","doi-asserted-by":"crossref","first-page":"99","DOI":"10.3113\/FAI-2009-0099","article-title":"Bioabsorbable screw fixation of the syndesmosis in unstable ankle injuries","volume":"30","author":"Ahmad","year":"2009","journal-title":"Foot Ankle Int"},{"key":"10.1053\/j.jfas.2015.03.014_bib5","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1053\/j.jfas.2005.01.010","article-title":"Distal tibiofibular syndesmosis fixation: a cadaveric, simulated fracture stabilization study comparing bioabsorbable and metallic single screw fixation","volume":"44","author":"Cox","year":"2005","journal-title":"J Foot Ankle Surg"},{"issue":"371","key":"10.1053\/j.jfas.2015.03.014_bib6","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/00003086-200002000-00026","article-title":"Adverse tissue reactions to bioabsorbable fixation devices","author":"B\u00f6stman","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2015.03.014_bib7","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1177\/107110070202300811","article-title":"Ruptured tibio-fibular syndesmosis: comparison study of metallic to bioabsorbable fixation","volume":"23","author":"Sinisaari","year":"2002","journal-title":"Foot Ankle Int"},{"key":"10.1053\/j.jfas.2015.03.014_bib8","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.3892\/etm.2013.1017","article-title":"Absorbable implants versus metal implants for the treatment of ankle fractures: a meta-analysis","volume":"5","author":"Li","year":"2013","journal-title":"Exp Ther Med"},{"key":"10.1053\/j.jfas.2015.03.014_bib9","doi-asserted-by":"crossref","first-page":"1755","DOI":"10.1007\/s00264-013-1999-x","article-title":"Internal fixation of distal tibiofibular syndesmotic injuries: a systematic review with meta-analysis","volume":"37","author":"Wang","year":"2013","journal-title":"Int Orthop"},{"key":"10.1053\/j.jfas.2015.03.014_bib10","doi-asserted-by":"crossref","first-page":"e1000097","DOI":"10.1371\/journal.pmed.1000097","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement","volume":"6","author":"Moher","year":"2009","journal-title":"PLoS Med"},{"key":"10.1053\/j.jfas.2015.03.014_bib11","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1097\/01.bot.0000155313.50627.f6","article-title":"Fixation of syndesmotic ruptures in 38 patients with a malleolar fracture: a randomized study comparing a metallic and a bioabsorbable screw","volume":"19","author":"Kaukonen","year":"2005","journal-title":"J Orthop Trauma"},{"key":"10.1053\/j.jfas.2015.03.014_bib12","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1007\/BF00435553","article-title":"A scoring scale for symptom evaluation after ankle fracture","volume":"103","author":"Olerud","year":"1984","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1053\/j.jfas.2015.03.014_bib13","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1302\/0301-620X.96B4.32171","article-title":"A prospective, randomised trial comparing the use of absorbable and metallic screws in the fixation of distal tibiofibular syndesmosis injuries: mid-term follow-up","volume":"96-B","author":"Sun","year":"2014","journal-title":"Bone Joint J"},{"key":"10.1053\/j.jfas.2015.03.014_bib14","doi-asserted-by":"crossref","first-page":"1346","DOI":"10.2106\/00004623-198769090-00007","article-title":"Fractures of the distal part of the fibula with associated disruption of the deltoid ligament: treatment without repair of the deltoid ligament","volume":"69","author":"Baird","year":"1987","journal-title":"J Bone Joint Surg Am"},{"key":"10.1053\/j.jfas.2015.03.014_bib15","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1177\/107110070102200411","article-title":"Bioabsorbable versus stainless steel screw fixation of the syndesmosis in pronation-lateral rotation ankle fractures: a prospective randomized trial","volume":"22","author":"Thordarson","year":"2001","journal-title":"Foot Ankle Int"},{"key":"10.1053\/j.jfas.2015.03.014_bib16","doi-asserted-by":"crossref","first-page":"26","DOI":"10.2106\/00004623-200201000-00005","article-title":"Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation","volume":"84-A","author":"Hovis","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"10.1053\/j.jfas.2015.03.014_bib17","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.1302\/0301-620X.87B11.16520","article-title":"Tissue restoration after resorption of polyglycolide and poly-laevo-lactic acid screws","volume":"87","author":"B\u00f6stman","year":"2005","journal-title":"J Bone Joint Surg Br"},{"key":"10.1053\/j.jfas.2015.03.014_bib18","series-title":"Clinical Uses of Absorbable Screws in Foot and Ankle Surgery","first-page":"85","author":"Cicchinelli","year":"1996"},{"key":"10.1053\/j.jfas.2015.03.014_bib19","doi-asserted-by":"crossref","first-page":"2788","DOI":"10.1021\/am300438k","article-title":"Crucial differences in the hydrolytic degradation between industrial polylactide and laboratory-scale poly(L-lactide)","volume":"4","author":"H\u00f6glund","year":"2012","journal-title":"ACS Appl Mater Interfaces"},{"key":"10.1053\/j.jfas.2015.03.014_bib20","doi-asserted-by":"crossref","first-page":"319","DOI":"10.2106\/00004623-199403000-00001","article-title":"Fixation with bioabsorbable screws for the treatment of fractures of the ankle","volume":"76","author":"Bucholz","year":"1994","journal-title":"J Bone Joint Surg Am"},{"key":"10.1053\/j.jfas.2015.03.014_bib21","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1302\/0301-620X.91B8.22430","article-title":"Outcome after fixation of ankle fractures with an injury to the syndesmosis: the effect of the syndesmosis screw","volume":"91","author":"Hamid","year":"2009","journal-title":"J Bone Joint Surg Br"},{"key":"10.1053\/j.jfas.2015.03.014_bib22","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.1016\/j.injury.2014.05.003","article-title":"Syndesmosis screws: how many, what diameter, where and should they be removed? A literature review","volume":"45","author":"Peek","year":"2014","journal-title":"Injury"},{"key":"10.1053\/j.jfas.2015.03.014_bib23","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1007\/s00402-010-1225-x","article-title":"To retain or remove the syndesmotic screw: a review of literature","volume":"131","author":"Schepers","year":"2011","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1053\/j.jfas.2015.03.014_bib24","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.3113\/FAI.2011.1040","article-title":"Complications of syndesmotic screw removal","volume":"32","author":"Schepers","year":"2011","journal-title":"Foot Ankle Int"},{"key":"10.1053\/j.jfas.2015.03.014_bib25","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/BOT.0000000000000245","article-title":"A prospective randomized multicenter trial comparing clinical outcomes of patients treated surgically with a static or dynamic implant for acute ankle syndesmosis rupture","volume":"29","author":"Laflamme","year":"2015","journal-title":"J Orthop Trauma"},{"issue":"329","key":"10.1053\/j.jfas.2015.03.014_bib26","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1097\/00003086-199608000-00029","article-title":"Metallic or absorbable fracture fixation devices: a cost minimization analysis","author":"B\u00f6stman","year":"1996","journal-title":"Clin Orthop Relat Res"}],"container-title":["The Journal of Foot and Ankle Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1067251615001143?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1067251615001143?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T04:59:30Z","timestamp":1761022770000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1067251615001143"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,7]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2015,7]]}},"alternative-id":["S1067251615001143"],"URL":"https:\/\/doi.org\/10.1053\/j.jfas.2015.03.014","relation":{},"ISSN":["1067-2516"],"issn-type":[{"value":"1067-2516","type":"print"}],"subject":[],"published":{"date-parts":[[2015,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Bioabsorbable Versus Metallic Screw Fixation for Tibiofibular Syndesmotic Ruptures: A Meta-Analysis","name":"articletitle","label":"Article Title"},{"value":"The Journal of Foot and Ankle Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1053\/j.jfas.2015.03.014","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Ltd. on behalf of the American College of Foot and Ankle Surgeons All rights reserved.","name":"copyright","label":"Copyright"}]}}