{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T10:55:00Z","timestamp":1793271300828,"version":"4.5.0"},"reference-count":30,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2015,11,1]],"date-time":"2015-11-01T00:00:00Z","timestamp":1446336000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,11,1]],"date-time":"2015-11-01T00:00:00Z","timestamp":1446336000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jfas.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Foot and Ankle Surgery"],"published-print":{"date-parts":[[2015,11]]},"DOI":"10.1053\/j.jfas.2015.04.017","type":"journal-article","created":{"date-parts":[[2015,7,23]],"date-time":"2015-07-23T09:00:17Z","timestamp":1437642017000},"page":"1021-1024","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":31,"title":["Fully Threaded Versus Partially Threaded Screws: Determining Shear in\u00a0Cancellous Bone Fixation"],"prefix":"10.1053","volume":"54","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2947-4782","authenticated-orcid":false,"given":"Michael W.","family":"Downey","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor","family":"Kosmopoulos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian B.","family":"Carpenter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1053\/j.jfas.2015.04.017_bib1","doi-asserted-by":"crossref","first-page":"12","DOI":"10.3928\/01477447-20121217-02","article-title":"History of the orthopedic screw","volume":"36","author":"Roberts","year":"2013","journal-title":"Orthopedics"},{"key":"10.1053\/j.jfas.2015.04.017_bib2","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1097\/00003086-198309000-00010","article-title":"Rigidity of pure lag-screw fixation as a function of screw inclination in an in\u00a0vitro spiral osteotomy","volume":"178","author":"Johner","year":"1983","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2015.04.017_bib3","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures: the scientific basis of biological internal fixation: choosing a new balance between stability and biology","volume":"84","author":"Perren","year":"2002","journal-title":"J Bone Joint Surg Br"},{"key":"10.1053\/j.jfas.2015.04.017_bib4","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1097\/00005131-200409000-00003","article-title":"Biomechanics of locked plates and screws","volume":"18","author":"Egol","year":"2004","journal-title":"J Orthop Trauma"},{"key":"10.1053\/j.jfas.2015.04.017_bib5","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1053\/jvet.2002.32398","article-title":"Comparison of insertion time and pullout strength between self-tapping and non-self-tapping AO 4.5-mm cortical bone screws in adult equine third metacarpal bone","volume":"31","author":"Andrea","year":"2002","journal-title":"Vet Surg"},{"key":"10.1053\/j.jfas.2015.04.017_bib6","first-page":"990","article-title":"The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone","volume":"64","author":"Battula","year":"2008","journal-title":"J Trauma"},{"key":"10.1053\/j.jfas.2015.04.017_bib7","doi-asserted-by":"crossref","first-page":"1138","DOI":"10.1016\/j.jbiomech.2009.12.007","article-title":"Pullout strength of suture anchors: effect of mechanical properties of trabecular bone","volume":"43","author":"Poukalova","year":"2010","journal-title":"J Biomech"},{"key":"10.1053\/j.jfas.2015.04.017_bib8","series-title":"F1839\u201308A: Standard Specification for Rigid Polyurethane Foam for Use as a Standard Material for Testing Orthopaedic Devices and Instruments","year":"2012"},{"key":"10.1053\/j.jfas.2015.04.017_bib9","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.jbiomech.2004.04.020","article-title":"A comparison of mechanical properties derived from multiple skeletal sites in mice","volume":"38","author":"Schriefer","year":"2005","journal-title":"J Biomech"},{"key":"10.1053\/j.jfas.2015.04.017_bib10","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1097\/00003086-199805000-00032","article-title":"Biomechanical assessment of compression screws","volume":"350","author":"Wheeler","year":"1998","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2015.04.017_bib11","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1097\/00003086-200004000-00034","article-title":"Mechanical properties of small fragment screws","volume":"373","author":"Collinge","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2015.04.017_bib12","first-page":"1073","article-title":"Laboratory testing of bolts and screws in cancellous bone","volume":"18","author":"Pratt","year":"1989","journal-title":"Orthop Rev"},{"key":"10.1053\/j.jfas.2015.04.017_bib13","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/0021-9290(68)90023-7","article-title":"A study of some factors which affect the strength of screws and their insertion and holding power in bone","volume":"1","author":"Ansell","year":"1968","journal-title":"J Biomech"},{"key":"10.1053\/j.jfas.2015.04.017_bib14","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1115\/1.2796022","article-title":"Factors affecting the pullout strength of cancellous bone screws","volume":"118","author":"Chapman","year":"1996","journal-title":"J Biomech Eng"},{"key":"10.1053\/j.jfas.2015.04.017_bib15","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1097\/00005131-199304000-00006","article-title":"Extraction strength of cannulated cancellous bone screws","volume":"7","author":"Hearn","year":"1993","journal-title":"J Orthop Trauma"},{"key":"10.1053\/j.jfas.2015.04.017_bib16","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1097\/00000658-194109000-00006","article-title":"Actual holding power of various screws in bone","volume":"114","author":"Lyon","year":"1941","journal-title":"Ann Surg"},{"key":"10.1053\/j.jfas.2015.04.017_bib17","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1016\/0021-9290(76)90168-8","article-title":"Force measurements in screw fixation","volume":"9","author":"Nunamaker","year":"1976","journal-title":"J Biomech"},{"key":"10.1053\/j.jfas.2015.04.017_bib18","doi-asserted-by":"crossref","first-page":"221","DOI":"10.3928\/0147-7447-19970301-06","article-title":"Complications when using the cannulated 3.5 mm screw system","volume":"20","author":"Schwend","year":"1997","journal-title":"Orthopedics"},{"key":"10.1053\/j.jfas.2015.04.017_bib19","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.2106\/00004623-197961080-00012","article-title":"Bone-mineral content, surface hardness, and mechanical fixation in the human radius: a correlative study","volume":"61","author":"Trader","year":"1979","journal-title":"J Bone Joint Surg Am"},{"key":"10.1053\/j.jfas.2015.04.017_bib20","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1302\/0301-620X.55B3.633","article-title":"Mechanical factors influencing the holding power of screws in compact bone","volume":"55","author":"Uhthoff","year":"1973","journal-title":"J Bone Joint Surg Br"},{"key":"10.1053\/j.jfas.2015.04.017_bib21","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/0268-0033(92)90026-Z","article-title":"Pull-out strengths for a range of screws inserted into the calcaneus: a preliminary study","volume":"7","author":"Muller","year":"1992","journal-title":"Clin Biomech"},{"key":"10.1053\/j.jfas.2015.04.017_bib22","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1053\/j.jfas.2010.02.006","article-title":"Comparison of pullout strength between 3.5-mm fully threaded, bicortical screws and 4.0-mm partially threaded, cancellous screws in the fixation of medial malleolar fractures","volume":"49","author":"Pollard","year":"2010","journal-title":"J Foot Ankle Surg"},{"key":"10.1053\/j.jfas.2015.04.017_bib23","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1097\/00005131-200109000-00006","article-title":"A fatigue life analysis of small fragment screws","volume":"15","author":"Merk","year":"2001","journal-title":"J Orthop Trauma"},{"key":"10.1053\/j.jfas.2015.04.017_bib24","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1097\/00003086-199708000-00035","article-title":"Pullout strengths of cannulated and noncannulated cancellous bone screws","volume":"341","author":"Thompson","year":"1997","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2015.04.017_bib25","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1053\/j.jfas.2003.09.007","article-title":"Comparison of pullout strength of small-diameter cannulated and solid-core screws","volume":"42","author":"Kissel","year":"2003","journal-title":"J Foot Ankle Surg"},{"key":"10.1053\/j.jfas.2015.04.017_bib26","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1097\/00003086-197509000-00032","article-title":"The effect of movement on the holding power of screws in bone","volume":"111","author":"Schatzker","year":"1975","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2015.04.017_bib27","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1302\/0301-620X.95B12.30498","article-title":"Screw fixation of medial malleolar fractures: a cadaveric biomechanical study challenging the current AO philosophy","volume":"95-B","author":"Parker","year":"2013","journal-title":"Bone Joint J"},{"key":"10.1053\/j.jfas.2015.04.017_bib28","series-title":"Skeletal Trauma: Fractures, Dislocations, Ligamentous Injuries","author":"Mazzocca","year":"1998"},{"key":"10.1053\/j.jfas.2015.04.017_bib29","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1097\/00005131-199004020-00012","article-title":"Optimizing bone screw pullout force","volume":"4","author":"DeCoster","year":"1990","journal-title":"J Orthop Trauma"},{"key":"10.1053\/j.jfas.2015.04.017_bib30","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1097\/BOT.0b013e318030261e","article-title":"Effect of screw torque level on cortical bone pullout strength","volume":"21","author":"Cleek","year":"2007","journal-title":"J Orthop Trauma"}],"container-title":["The Journal of Foot and Ankle Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1067251615001805?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1067251615001805?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T04:59:22Z","timestamp":1761022762000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1067251615001805"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11]]},"references-count":30,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2015,11]]}},"alternative-id":["S1067251615001805"],"URL":"https:\/\/doi.org\/10.1053\/j.jfas.2015.04.017","relation":{},"ISSN":["1067-2516"],"issn-type":[{"value":"1067-2516","type":"print"}],"subject":[],"published":{"date-parts":[[2015,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Fully Threaded Versus Partially Threaded Screws: Determining Shear in\u00a0Cancellous Bone Fixation","name":"articletitle","label":"Article Title"},{"value":"The Journal of Foot and Ankle Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1053\/j.jfas.2015.04.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Ltd. on behalf of the American College of Foot and Ankle Surgeons All rights reserved.","name":"copyright","label":"Copyright"}]}}