{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T00:20:45Z","timestamp":1761092445112,"version":"build-2065373602"},"reference-count":48,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T00:00:00Z","timestamp":1635724800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T00:00:00Z","timestamp":1635724800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100003121","name":"Ferdowsi University of Mashhad","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003121","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jfas.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Foot and Ankle Surgery"],"published-print":{"date-parts":[[2021,11]]},"DOI":"10.1053\/j.jfas.2021.02.013","type":"journal-article","created":{"date-parts":[[2021,5,11]],"date-time":"2021-05-11T04:50:47Z","timestamp":1620708647000},"page":"1169-1174","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Optimization of Connecting Rod Design Parameters for External Fixation System: A Biomechanical Study"],"prefix":"10.1053","volume":"60","author":[{"given":"Reza","family":"Kolasangiani","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kiana","family":"Parchami","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masoud","family":"Tahani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1053\/j.jfas.2021.02.013_bib0001","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/01.TA.0000075787.69695.4E","article-title":"Impact of intramedullary instrumentation versus damage control for femoral fractures on immunoinflammatory parameters: prospective randomized analysis by the EPOFF Study Group","volume":"55","author":"Pape","year":"2003","journal-title":"J Trauma Acute Care Surg"},{"key":"10.1053\/j.jfas.2021.02.013_bib0002","doi-asserted-by":"crossref","first-page":"3441","DOI":"10.1097\/00003246-200010000-00012","article-title":"Biochemical changes after trauma and skeletal surgery of the lower extremity: quantification of the operative burden","volume":"28","author":"Pape","year":"2000","journal-title":"Crit Care Med"},{"key":"10.1053\/j.jfas.2021.02.013_bib0003","doi-asserted-by":"crossref","first-page":"1598","DOI":"10.1016\/j.proeng.2015.01.533","article-title":"Finite element analysis and experimental testing of stiffness of the Sarafix external fixator","volume":"100","author":"Elmedin","year":"2015","journal-title":"Procedia Eng"},{"key":"10.1053\/j.jfas.2021.02.013_bib0004","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1097\/00003086-198309000-00014","article-title":"Bending stiffness of unilateral and bilateral fixator frames","author":"Behrens","year":"1983","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2021.02.013_bib0005","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1097\/00003086-198904000-00012","article-title":"A biomechanical analysis of the Ilizarov external fixator","volume":"241","author":"Fleming","year":"1989","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2021.02.013_bib0006","first-page":"433","article-title":"Fixation stiffness of Dynafix unilateral external fixator in neutral and non-neutral configurations","volume":"15","author":"Koo","year":"2005","journal-title":"Biomed Mater Eng"},{"key":"10.1053\/j.jfas.2021.02.013_bib0007","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1111\/j.1532-950X.2005.00106.x","article-title":"Biomechanical analysis of unilateral external skeletal fixators combined with IM-pin and without IM-pin using finite-element method","volume":"35","author":"Radke","year":"2006","journal-title":"Vet Surg"},{"key":"10.1053\/j.jfas.2021.02.013_bib0008","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/S0021-9290(97)00127-9","article-title":"Analysis of inter-fragmentary movement as a function of musculoskeletal loading conditions in sheep","volume":"31","author":"Duda","year":"1997","journal-title":"J Biomech"},{"key":"10.1053\/j.jfas.2021.02.013_bib0009","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.jmbbm.2015.10.029","article-title":"Biomechanical evaluation of intramedullary nail and bone plate for the fixation of distal metaphyseal fractures","volume":"56","author":"Nourisa","year":"2016","journal-title":"J Mech Behav Biomed"},{"key":"10.1053\/j.jfas.2021.02.013_bib0010","doi-asserted-by":"crossref","first-page":"2953","DOI":"10.1016\/j.compstruct.2011.05.008","article-title":"Finite element analysis using interfragmentary strain theory for the fracture healing process to which composite bone plates are applied","volume":"93","author":"Kim","year":"2011","journal-title":"Compos Struct"},{"key":"10.1053\/j.jfas.2021.02.013_bib0011","first-page":"175","article-title":"Physical and biological aspects of fracture healing with special reference to internal fixation","author":"Perren","year":"1979","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2021.02.013_bib0012","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1016\/S0021-9290(02)00086-6","article-title":"A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading","volume":"35","author":"Lacroix","year":"2002","journal-title":"J Biomech"},{"key":"10.1053\/j.jfas.2021.02.013_bib0013","doi-asserted-by":"crossref","first-page":"S24","DOI":"10.1016\/S0020-1383(15)30015-2","article-title":"Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur","volume":"46","author":"Heyland","year":"2015","journal-title":"Injury"},{"key":"10.1053\/j.jfas.2021.02.013_bib0014","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1002\/jor.1100150414","article-title":"Influence of size and stability of the osteotomy gap on the success of fracture healing","volume":"15","author":"Claes","year":"1997","journal-title":"J Orthop Res"},{"key":"10.1053\/j.jfas.2021.02.013_bib0015","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1007\/s12541-011-0149-x","article-title":"Design optimization of a xenogeneic bone plate and screws using the Taguchi and finite element methods","volume":"12","author":"Kim","year":"2011","journal-title":"Int J PR ENG MAN-GT"},{"key":"10.1053\/j.jfas.2021.02.013_bib0016","doi-asserted-by":"crossref","DOI":"10.1155\/2019\/5636528","article-title":"Finite element-and design of experiment-derived optimization of screw configurations and a locking plate for internal fixation system","volume":"2019","author":"Sheng","year":"2019","journal-title":"Comput Math Methods Med"},{"key":"10.1053\/j.jfas.2021.02.013_bib0017","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1007\/s00068-014-0436-1","article-title":"Biomechanical properties of different external fixator frame configurations","volume":"41","author":"Sellei","year":"2015","journal-title":"Eur J Trauma Emerg Surg"},{"key":"10.1053\/j.jfas.2021.02.013_bib0018","doi-asserted-by":"crossref","first-page":"S23","DOI":"10.1016\/S0020-1383(15)30007-3","article-title":"External fixation design evolution enhances biomechanical frame performance","volume":"46","author":"Sellei","year":"2015","journal-title":"Injury"},{"key":"10.1053\/j.jfas.2021.02.013_bib0019","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1002\/jor.1100040108","article-title":"Guidelines for external fixation frame rigidity and stresses","volume":"4","author":"Huiskes","year":"1986","journal-title":"J Orthop Res"},{"key":"10.1053\/j.jfas.2021.02.013_bib0020","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1055\/s-0038-1632764","article-title":"Influence of the connecting rod on the biomechanical properties of five external skeletal fixation configurations","volume":"16","author":"Bronson","year":"2003","journal-title":"Vet Comp Orthop Traumatol"},{"key":"10.1053\/j.jfas.2021.02.013_bib0021","first-page":"646","article-title":"Relationship between rigidity of external fixator and number of pins: computer analysis using finite elements","volume":"47","author":"Sternick","year":"2012","journal-title":"Rev Bras Fisioter"},{"key":"10.1053\/j.jfas.2021.02.013_bib0022","first-page":"299","article-title":"The effect of wire configuration on the stability of the Ilizarov external fixator","author":"Orbay","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2021.02.013_bib0023","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.3928\/0147-7447-19880701-09","article-title":"Mechanical performance of the standard Orthofix external fixator","volume":"11","author":"Chao","year":"1988","journal-title":"Orthopedics"},{"key":"10.1053\/j.jfas.2021.02.013_bib0024","doi-asserted-by":"crossref","first-page":"734","DOI":"10.2106\/00004623-198769050-00015","article-title":"Stability of ten configurations of the Hoffmann external-fixation frame","volume":"69","author":"Finlay","year":"1987","journal-title":"J Bone Joint Surg Am"},{"key":"10.1053\/j.jfas.2021.02.013_bib0025","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.simpat.2018.01.009","article-title":"Simulation and sensitivity analysis of wear on the automotive brake pad","volume":"84","author":"Hatam","year":"2018","journal-title":"Simul Model Pract Theory"},{"key":"10.1053\/j.jfas.2021.02.013_bib0026","first-page":"53","article-title":"An application of finite element method and design of experiments in the optimization of sheet metal blanking process","volume":"2","author":"Al-Momani","year":"2008","journal-title":"JJMIE"},{"key":"10.1053\/j.jfas.2021.02.013_bib0027","doi-asserted-by":"crossref","first-page":"3229","DOI":"10.1016\/j.jbiomech.2008.08.003","article-title":"Evaluation of bone plate with low-stiffness material in terms of stress distribution","volume":"41","author":"Benli","year":"2008","journal-title":"J Biomech"},{"key":"10.1053\/j.jfas.2021.02.013_bib0028","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/1475-925X-4-46","article-title":"Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates","volume":"4","author":"Ganesh","year":"2005","journal-title":"Biomed Eng Online"},{"key":"10.1053\/j.jfas.2021.02.013_bib0029","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1002\/jor.21362","article-title":"Simulation of fracture healing in the tibia: mechanoregulation of cell activity using a lattice modeling approach","volume":"29","author":"Byrne","year":"2011","journal-title":"J Orthop Res"},{"key":"10.1053\/j.jfas.2021.02.013_bib0030","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.compositesb.2013.08.004","article-title":"The finite element analysis for endochondral ossification process of a fractured tibia applied with a composite IM-rod based on a mechano-regulation theory using a deviatoric strain","volume":"56","author":"Son","year":"2014","journal-title":"Compos B Eng"},{"key":"10.1053\/j.jfas.2021.02.013_bib0031","first-page":"76","article-title":"Stability of tibial defect reconstruction with fibular graft and unilateral external fixation: a finite element study","volume":"7","author":"Chen","year":"2014","journal-title":"Int J Clin Exp Med"},{"key":"10.1053\/j.jfas.2021.02.013_bib0032","first-page":"273","article-title":"Experimental study of the effect of weight bearing on fracture healing in the canine tibia","volume":"302","author":"O\u2019Sullivan","year":"1994","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2021.02.013_bib0033","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1302\/0301-620X.67B4.4030869","article-title":"The influence of induced micromovement upon the healing of experimental tibial fractures","volume":"67","author":"Goodship","year":"1985","journal-title":"J Bone Joint Surg Br"},{"key":"10.1053\/j.jfas.2021.02.013_bib0034","doi-asserted-by":"crossref","first-page":"598","DOI":"10.2106\/00004623-198567040-00015","article-title":"External skeletal fixation of canine tibial osteotomies. Compression compared with no compression","volume":"67","author":"Hart","year":"1985","journal-title":"JBJS"},{"key":"10.1053\/j.jfas.2021.02.013_bib0035","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.2106\/00004623-198466070-00016","article-title":"Comparison of the effects of compression plates and external fixators on early bone-healing","volume":"66","author":"Lewallen","year":"1984","journal-title":"J Bone Joint Surg Am"},{"key":"10.1053\/j.jfas.2021.02.013_bib0036","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1302\/0301-620X.60B2.350882","article-title":"The biology of fracture healing in long bones","volume":"60","author":"McKibbin","year":"1978","journal-title":"J Bone Joint Surg Br"},{"key":"10.1053\/j.jfas.2021.02.013_bib0037","doi-asserted-by":"crossref","first-page":"369","DOI":"10.2106\/00004623-197759030-00014","article-title":"Fracture healing in rat femora as affected by functional weight-bearing","volume":"59","author":"Sarmiento","year":"1977","journal-title":"J Bone Joint Surg Am"},{"key":"10.1053\/j.jfas.2021.02.013_bib0038","doi-asserted-by":"crossref","first-page":"355","DOI":"10.2106\/00004623-198769030-00006","article-title":"The early healing of tibial osteotomies stabilized by one-plane or two-plane external fixation","volume":"69","author":"Williams","year":"1987","journal-title":"J Bone Joint Surg Am"},{"key":"10.1053\/j.jfas.2021.02.013_bib0039","doi-asserted-by":"crossref","first-page":"1258","DOI":"10.2106\/00004623-198466080-00015","article-title":"Comparison of osteotomy healing under external fixation devices with different stiffness characteristics","volume":"66","author":"Wu","year":"1984","journal-title":"J Bone Joint Surg Am"},{"year":"2000","series-title":"AO Principles of Fracture Management","author":"Ruedi","key":"10.1053\/j.jfas.2021.02.013_bib0040"},{"key":"10.1053\/j.jfas.2021.02.013_bib0041","first-page":"216","article-title":"Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness","volume":"6","author":"Ang","year":"2017","journal-title":"Bone Joint J"},{"key":"10.1053\/j.jfas.2021.02.013_bib0042","doi-asserted-by":"crossref","first-page":"S41","DOI":"10.1097\/00003086-199810001-00006","article-title":"Mechanobiology of skeletal regeneration","volume":"355","author":"Carter","year":"1998","journal-title":"Clin Orthop Relat Res"},{"key":"10.1053\/j.jfas.2021.02.013_bib0043","first-page":"63","article-title":"The concept of interfragmentary strain. In:","author":"Perren","year":"1980","journal-title":"HK Uhthoff, E Stahl eds. Current concepts of internal fixation of fractures. Springer, Berlin Heidelberg New York"},{"key":"10.1053\/j.jfas.2021.02.013_bib0044","doi-asserted-by":"crossref","first-page":"1525","DOI":"10.1016\/j.bbe.2020.09.007","article-title":"Bone fracture healing under external fixator: Investigating impacts of several design parameters using Taguchi and ANOVA","volume":"40","author":"Kolasangiani","year":"2020","journal-title":"Biocybern Biomed Eng"},{"key":"10.1053\/j.jfas.2021.02.013_bib0045","doi-asserted-by":"crossref","first-page":"e3199","DOI":"10.1002\/cnm.3199","article-title":"Bone fracture healing under Ilizarov fixator: Influence of fixator configuration, fracture geometry, and loading","volume":"35","author":"Ganadhiepan","year":"2019","journal-title":"Int J Numer Method Biomed Eng"},{"key":"10.1053\/j.jfas.2021.02.013_bib0046","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1016\/S0736-0266(02)00259-0","article-title":"The initial phase of fracture healing is specifically sensitive to mechanical conditions","volume":"21","author":"Klein","year":"2003","journal-title":"J Orthop Res"},{"key":"10.1053\/j.jfas.2021.02.013_bib0047","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1007\/s001130050327","article-title":"Loosening of Schanz screws in external fixator montage of the lower extremity","volume":"101","author":"Pommer","year":"1998","journal-title":"Der Unfallchirurg"},{"key":"10.1053\/j.jfas.2021.02.013_bib0048","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/S0021-9290(98)00153-5","article-title":"Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing","volume":"32","author":"Claes","year":"1999","journal-title":"J Biomech"}],"container-title":["The Journal of Foot and Ankle Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1067251621001666?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1067251621001666?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T05:10:10Z","timestamp":1761023410000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1067251621001666"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11]]},"references-count":48,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,11]]}},"alternative-id":["S1067251621001666"],"URL":"https:\/\/doi.org\/10.1053\/j.jfas.2021.02.013","relation":{},"ISSN":["1067-2516"],"issn-type":[{"type":"print","value":"1067-2516"}],"subject":[],"published":{"date-parts":[[2021,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Optimization of Connecting Rod Design Parameters for External Fixation System: A Biomechanical Study","name":"articletitle","label":"Article Title"},{"value":"The Journal of Foot and Ankle Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1053\/j.jfas.2021.02.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 by the American College of Foot and Ankle Surgeons. All rights reserved.","name":"copyright","label":"Copyright"}]}}