{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T00:18:53Z","timestamp":1761005933521,"version":"build-2065373602"},"reference-count":12,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2012,12,1]],"date-time":"2012-12-01T00:00:00Z","timestamp":1354320000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2012,12,1]],"date-time":"2012-12-01T00:00:00Z","timestamp":1354320000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2012,12,1]],"date-time":"2012-12-01T00:00:00Z","timestamp":1354320000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2012,12,1]],"date-time":"2012-12-01T00:00:00Z","timestamp":1354320000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2012,12,1]],"date-time":"2012-12-01T00:00:00Z","timestamp":1354320000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2012,12,1]],"date-time":"2012-12-01T00:00:00Z","timestamp":1354320000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2012,12,1]],"date-time":"2012-12-01T00:00:00Z","timestamp":1354320000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jcardioanesthesia.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiothoracic and Vascular Anesthesia"],"published-print":{"date-parts":[[2012,12]]},"DOI":"10.1053\/j.jvca.2012.07.002","type":"journal-article","created":{"date-parts":[[2012,9,7]],"date-time":"2012-09-07T06:15:32Z","timestamp":1346998532000},"page":"1063-1066","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["Monitoring of Aortic Valve Opening and Systolic Aortic Insufficiency in Optimization of Continuous-Flow Left Ventricular Assist Device Settings"],"prefix":"10.1053","volume":"26","author":[{"given":"Edward","family":"Gologorsky","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Angela","family":"Gologorsky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Si M.","family":"Pham","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1053\/j.jvca.2012.07.002_bib1","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1161\/CIRCHEARTFAILURE.110.959023","article-title":"Unforeseen consequences of therapy with continuous-flow pumps","volume":"3","author":"Frazier","year":"2010","journal-title":"Circ Heart Fail"},{"key":"10.1053\/j.jvca.2012.07.002_bib2","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1161\/CIRCHEARTFAILURE.109.917765","article-title":"The development of aortic insufficiency in LVAD supported patients","volume":"3","author":"Cowger","year":"2010","journal-title":"Circ Heart Fail"},{"key":"10.1053\/j.jvca.2012.07.002_bib3","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1253\/circj.CJ-10-1106","article-title":"Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device","volume":"75","author":"Hatano","year":"2011","journal-title":"Circ J"},{"key":"10.1053\/j.jvca.2012.07.002_bib4","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/S0003-4975(00)02639-4","article-title":"Heartmate II left ventricular assist system: From concept to first clinical use","volume":"71","author":"Griffith","year":"2001","journal-title":"Ann Thorac Surg"},{"key":"10.1053\/j.jvca.2012.07.002_bib5","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.healun.2010.01.011","article-title":"Clinical management of continuous-flow left ventricular assist devices in advanced heart failure","volume":"29","author":"Slaughter","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.jvca.2012.07.002_bib6","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.echo.2010.11.012","article-title":"Transthoracic echocardiographic assessment of continuous-flow left ventricular assist devices","volume":"24","author":"Rasalingam","year":"2011","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1053\/j.jvca.2012.07.002_bib7","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1016\/j.jacc.2005.01.037","article-title":"Left ventricular assist device malfunction","volume":"45","author":"Horton","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"10.1053\/j.jvca.2012.07.002_bib8","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1213\/01.ane.0000278088.22952.82","article-title":"Perioperative echocardiographic examination for ventricular assist device implantation","volume":"105","author":"Chumnanvej","year":"2007","journal-title":"Anesth Analg"},{"key":"10.1053\/j.jvca.2012.07.002_bib9","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.healun.2009.08.027","article-title":"A novel non-invasive method to assess aortic valve opening in HeartMate II left ventricular assist device patients using a modified Karhunen-Lo\u00e8ve transformation","volume":"29","author":"Bishop","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.jvca.2012.07.002_bib10","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1067\/mje.2000.105009","article-title":"Clinical utility of echocardiography in the management of ventricular assist devices","volume":"13","author":"Scalia","year":"2000","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1053\/j.jvca.2012.07.002_bib11","first-page":"309","article-title":"Influence of left ventricular assist on valvular regurgitation","volume":"88","author":"Holman","year":"1993","journal-title":"Circulation"},{"key":"10.1053\/j.jvca.2012.07.002_bib12","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1213\/ane.0b013e3181806009","article-title":"Transesophageal echocardiography in a patient in hemodynamic compromise after Jarvick\u2122 2000 implantation: The suckdown effect","volume":"107","author":"Mauermann","year":"2008","journal-title":"Anesth Analg"}],"container-title":["Journal of Cardiothoracic and Vascular Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S105307701200345X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S105307701200345X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T07:40:12Z","timestamp":1760946012000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S105307701200345X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,12]]},"references-count":12,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2012,12]]}},"alternative-id":["S105307701200345X"],"URL":"https:\/\/doi.org\/10.1053\/j.jvca.2012.07.002","relation":{},"ISSN":["1053-0770"],"issn-type":[{"type":"print","value":"1053-0770"}],"subject":[],"published":{"date-parts":[[2012,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Monitoring of Aortic Valve Opening and Systolic Aortic Insufficiency in Optimization of Continuous-Flow Left Ventricular Assist Device Settings","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiothoracic and Vascular Anesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1053\/j.jvca.2012.07.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2012 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}