{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T00:19:16Z","timestamp":1761005956026,"version":"build-2065373602"},"reference-count":26,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jcardioanesthesia.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiothoracic and Vascular Anesthesia"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1053\/j.jvca.2019.07.127","type":"journal-article","created":{"date-parts":[[2019,7,20]],"date-time":"2019-07-20T10:29:00Z","timestamp":1563618540000},"page":"562-565","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Reduced Flow Rate, Acute Hemolysis, and Restricted Anterior Mitral Leaflet Opening During Mechanical Circulatory Support for End-stage Nonischemic Cardiomyopathy"],"prefix":"10.1053","volume":"34","author":[{"given":"Timothy J.","family":"Lazicki","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul S.","family":"Pagel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1053\/j.jvca.2019.07.127_bib0001","doi-asserted-by":"crossref","first-page":"3523","DOI":"10.1093\/eurheartj\/ehx363","article-title":"Percutaneous short-term active mechanical support devices in cardiogenic shock: A systematic review and collaborative meta-analysis of randomized trials","volume":"38","author":"Thiele","year":"2017","journal-title":"Eur Heart J"},{"key":"10.1053\/j.jvca.2019.07.127_bib0002","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.ahj.2018.03.024","article-title":"Analysis of outcomes for 15,259 US patients with acute myocardial infarction cardiogenic shock (AMICS) supported with the Impella device","volume":"202","author":"O'Neill","year":"2018","journal-title":"Am Heart J"},{"key":"10.1053\/j.jvca.2019.07.127_bib0003","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1161\/CIRCULATIONAHA.118.036614","article-title":"Impella support for acute myocardial infarction complicated by cardiogenic shock","volume":"139","author":"Schrage","year":"2019","journal-title":"Circulation"},{"key":"10.1053\/j.jvca.2019.07.127_bib0004","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1161\/CIRCULATIONAHA.112.098194","article-title":"A prospective, randomized clinical trial of hemodynamic support with Impella 2.5 versus intra-aortic balloon pump in patients undergoing high-risk percutaneous coronary intervention: The PROTECT II study","volume":"126","author":"O'Neill","year":"2012","journal-title":"Circulation"},{"key":"10.1053\/j.jvca.2019.07.127_bib0005","first-page":"672","article-title":"Avoiding hemodynamic collapse during high-risk percutaneous coronary intervention: Advanced hemodynamics of impella support","volume":"89","author":"Verma","year":"2017","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1053\/j.jvca.2019.07.127_bib0006","first-page":"309","article-title":"Percutaneous mechanical circulatory support for cardiac disease: Temporal trends in use and complications between 2009 and 2015","volume":"29","author":"Ternus","year":"2017","journal-title":"J Invasive Cardiol"},{"key":"10.1053\/j.jvca.2019.07.127_bib0007","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1111\/joic.12377","article-title":"Impella 2.5 initiated prior to unprotected left main PCI in acute myocardial infarction complicated by cardiogenic shock improves early survival","volume":"30","author":"Meraj","year":"2017","journal-title":"J Interv Cardiol"},{"key":"10.1053\/j.jvca.2019.07.127_bib0008","first-page":"576","article-title":"Real-world supported unprotected left main percutaneous coronary intervention with impella device; data from the USpella registry","volume":"90","author":"Schreiber","year":"2017","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1053\/j.jvca.2019.07.127_bib0009","doi-asserted-by":"crossref","first-page":"e12665","DOI":"10.1097\/MD.0000000000012665","article-title":"Unprotected versus protected high-risk percutaneous coronary intervention with the Impella 2.5 in patients with multivessel disease and severely reduced left ventricular function","volume":"97","author":"Becher","year":"2018","journal-title":"Medicine (Baltimore)"},{"key":"10.1053\/j.jvca.2019.07.127_bib0010","first-page":"725","article-title":"Microaxial devices for ventricular failure: A multicentre, population-based experience","volume":"27","author":"Higgins","year":"2011","journal-title":"Can J Cardiol"},{"key":"10.1053\/j.jvca.2019.07.127_bib0011","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1016\/j.jtcvs.2012.01.067","article-title":"The RECOVER I: A multicenter prospective study of Impella 5.0\/LD for postcardiotomy circulatory support","volume":"145","author":"Griffith","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1053\/j.jvca.2019.07.127_bib0012","first-page":"87","article-title":"Short-term mechanical circulatory support with the Impella 5.0 device for cardiogenic shock at La Pitie-Salpertriere","volume":"6","author":"Mastroianni","year":"2017","journal-title":"Eur Heart J Acute Cardiovasc Care"},{"key":"10.1053\/j.jvca.2019.07.127_bib0013","doi-asserted-by":"crossref","first-page":"1622","DOI":"10.1016\/j.amjcard.2016.02.038","article-title":"Effectiveness and safety of the Impella 5.0 as a bridge to cardiac transplantation or durable left ventricular assist device","volume":"117","author":"Lima","year":"2016","journal-title":"Am J Cardiol"},{"key":"10.1053\/j.jvca.2019.07.127_bib0014","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/j.jvs.2015.03.040","article-title":"Incidence and prognosis of vascular complications after percutaneous placement of left ventricular assist device","volume":"62","author":"Abaunza","year":"2015","journal-title":"J Vasc Surg"},{"key":"10.1053\/j.jvca.2019.07.127_bib0015","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1053\/j.jvca.2014.09.018","article-title":"Coiled Impella drive line in the left ventricle: A rare complication of a left ventricular assist device","volume":"29","author":"Pantin","year":"2015","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1053\/j.jvca.2019.07.127_bib0016","first-page":"E1","article-title":"Acute intraventricular thrombosis of an Impella LP 5.0 device in an ST-elevated myocardial infarction complicated by cardiogenic shock","volume":"25","author":"Ranc","year":"2013","journal-title":"J Invasive Cardiol"},{"key":"10.1053\/j.jvca.2019.07.127_bib0017","first-page":"412","article-title":"Functional mitral stenosis: A rare complication of the Impella assist device","volume":"9","author":"Toggweiler","year":"2008","journal-title":"Eur J Echocardiogr"},{"key":"10.1053\/j.jvca.2019.07.127_bib0018","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1111\/j.1540-8191.2012.01454.x","article-title":"Severe aortic insufficiency secondary to 5L Impella device placement","volume":"27","author":"Chandola","year":"2012","journal-title":"J Card Surg"},{"key":"10.1053\/j.jvca.2019.07.127_bib0019","doi-asserted-by":"crossref","first-page":"e9","DOI":"10.1016\/j.ijcard.2014.06.057","article-title":"Persistent aortic insufficiency secondary to Impella device implantation","volume":"176","author":"Sharma","year":"2014","journal-title":"Int J Cardiol"},{"key":"10.1053\/j.jvca.2019.07.127_bib0020","doi-asserted-by":"crossref","first-page":"e100","DOI":"10.1016\/j.hlc.2013.10.098","article-title":"Acute mitral regurgitation: Unforeseen new complication of the Impella LP 5.0 ventricular assist device and review of the literature","volume":"23","author":"Elhussein","year":"2014","journal-title":"Heart Lung Circ"},{"key":"10.1053\/j.jvca.2019.07.127_bib0021","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1016\/j.amjcard.2016.02.007","article-title":"Perforation of the anterior mitral leaflet after Impella LP 5.0 therapy in cardiogenic shock","volume":"117","author":"Eftekhari","year":"2016","journal-title":"Am J Cardiol"},{"key":"10.1053\/j.jvca.2019.07.127_bib0022","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1016\/j.amjcard.2016.12.020","article-title":"Acute mitral regurgitation after removal of an Impella device","volume":"119","author":"Bhatia","year":"2017","journal-title":"Am J Cardiol"},{"key":"10.1053\/j.jvca.2019.07.127_bib0023","first-page":"894","article-title":"Left ventricular perforation after Impella placement in a patient with cardiogenic shock","volume":"91","author":"Peritz","year":"2018","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1053\/j.jvca.2019.07.127_bib0024","first-page":"840","article-title":"Severe hemolysis associated with use of the Impella LP 2.5 mechanical assist device","volume":"80","author":"Sibbald","year":"2012","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1053\/j.jvca.2019.07.127_bib0025","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.carrev.2012.10.011","article-title":"An unexpected cause of massive hemolysis in percutaneous left ventricular assist device","volume":"14","author":"Tanawuttiwat","year":"2013","journal-title":"Cardiovasc Revasc Med"},{"key":"10.1053\/j.jvca.2019.07.127_bib0026","article-title":"Impella induced massive hemolysis: Reemphasizing echocardiographic guidance for correct placement","author":"Cardozo","year":"2015","journal-title":"Case Rep Cardiol"}],"container-title":["Journal of Cardiothoracic and Vascular Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1053077019307669?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1053077019307669?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T07:47:07Z","timestamp":1760946427000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053077019307669"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["S1053077019307669"],"URL":"https:\/\/doi.org\/10.1053\/j.jvca.2019.07.127","relation":{},"ISSN":["1053-0770"],"issn-type":[{"type":"print","value":"1053-0770"}],"subject":[],"published":{"date-parts":[[2020,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Reduced Flow Rate, Acute Hemolysis, and Restricted Anterior Mitral Leaflet Opening During Mechanical Circulatory Support for End-stage Nonischemic Cardiomyopathy","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiothoracic and Vascular Anesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1053\/j.jvca.2019.07.127","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}