{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T09:30:58Z","timestamp":1775295058789,"version":"3.50.1"},"reference-count":35,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["semthorcardiovascsurg.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Seminars in Thoracic and Cardiovascular Surgery"],"published-print":{"date-parts":[[2016]]},"DOI":"10.1053\/j.semtcvs.2016.05.013","type":"journal-article","created":{"date-parts":[[2016,6,14]],"date-time":"2016-06-14T10:13:24Z","timestamp":1465899204000},"page":"363-375","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":26,"title":["A Decade of Experience With Continuous-Flow Left Ventricular Assist Devices"],"prefix":"10.1053","volume":"28","author":[{"given":"Ranjit","family":"John","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher T.","family":"Holley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Eckman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samit S.","family":"Roy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rebecca","family":"Cogswell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Harvey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sara","family":"Shumway","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth","family":"Liao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"20","key":"10.1053\/j.semtcvs.2016.05.013_bib1","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1056\/NEJMoa012175","article-title":"Long-term mechanical left ventricular assistance for end-stage heart failure","volume":"345","author":"Rose","year":"2001","journal-title":"N Engl J Med"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib2","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1056\/NEJMoa067758","article-title":"Use of a continuous-flow device in patients awaiting heart transplantation","volume":"357","author":"Miller","year":"2007","journal-title":"N Engl J Med"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib3","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.jacc.2009.03.055","article-title":"Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device","volume":"54","author":"Pagani","year":"2009","journal-title":"J Am Coll Cardiol"},{"issue":"19","key":"10.1053\/j.semtcvs.2016.05.013_bib4","doi-asserted-by":"crossref","first-page":"1890","DOI":"10.1016\/j.jacc.2010.10.062","article-title":"Results of the Post-FDA-Approval Study with a Continuous Flow Left Ventricular Assist Device as a Bridge to Heart Transplantation: A prospective study using the INTERMACS Registry","volume":"57","author":"Starling","year":"2011","journal-title":"J Am Col Cardiol."},{"key":"10.1053\/j.semtcvs.2016.05.013_bib5","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1056\/NEJMoa0909938","article-title":"Advanced heart failure treated with continuous-flow left ventricular assist device","volume":"361","author":"Slaughter","year":"2009","journal-title":"N Engl J Med"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib6","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1016\/j.healun.2013.04.004","article-title":"HeartWare ventricular assist system for bridge to transplant: Combined results of the bridge to transplant and continued access protocol trial","volume":"32","author":"Slaughter","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib7","doi-asserted-by":"crossref","first-page":"1751","DOI":"10.1016\/j.jacc.2014.01.053","article-title":"Results of the destination therapy post-food and drug administration approval study with a continuous flow left ventricular assist device: A prospective study using the INTERMACS registry (Interagency Registry for Mechanically Assisted Circulatory Support)","volume":"63","author":"Jorde","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib8","first-page":"450","article-title":"In vivo evaluation of a peripheral vascular access axial flow blood pump","volume":"34","author":"Wampler","year":"1988","journal-title":"Trans Am Soc Artif Intern Organs"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib9","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1016\/j.jtcvs.2007.12.028","article-title":"Longer duration of continuous-flow ventricular assist device support predicts greater hemodynamic compromise after return to pulsatility","volume":"136","author":"Stewart","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib10","doi-asserted-by":"crossref","first-page":"1826","DOI":"10.1016\/j.jacc.2009.12.052","article-title":"Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients","volume":"55","author":"Rogers","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib11","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.healun.2010.01.011","article-title":"Clinical management of continuous-flow left ventricular assist devices in advanced heart failure","volume":"29","author":"Slaughter","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib12","doi-asserted-by":"crossref","unstructured":"John R, Kamdar F, Liao K, et al. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy. Ann Thorac Surg 2008;86:1227-1234; [discussion 34-5]","DOI":"10.1016\/j.athoracsur.2008.06.030"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib13","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.1016\/j.athoracsur.2011.06.081","article-title":"Lessons learned from experience with over 100 consecutive HeartMate II left ventricular assist devices","volume":"92","author":"John","year":"2011","journal-title":"Ann Thoracic Surg"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib14","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1016\/j.healun.2008.07.021","article-title":"INTERMACS database for durable devices for circulatory support: First annual report","volume":"27","author":"Kirklin","year":"2008","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib15","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.healun.2013.08.021","article-title":"Hemolysis: A harbinger of adverse outcome after left ventricular assist device implant","volume":"33","author":"Cowger","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib16","doi-asserted-by":"crossref","first-page":"2162","DOI":"10.1016\/j.jacc.2009.02.048","article-title":"Severely impaired von Willebrand factor-dependent platelet aggregation in patients with a continuous-flow left ventricular assist device (HeartMate II)","volume":"53","author":"Klovaite","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib17","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1111\/j.1540-8191.2010.01025.x","article-title":"Increased incidence of gastrointestinal bleeding following implantation of the HeartMate II LVAD","volume":"25","author":"Stern","year":"2010","journal-title":"J Card Surg"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib18","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jtcvs.2008.07.032","article-title":"Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices","volume":"137","author":"Crow","year":"2009","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib19","doi-asserted-by":"crossref","first-page":"3038","DOI":"10.1161\/CIRCULATIONAHA.111.040246","article-title":"Bleeding and thrombosis in patients with continuous-flow ventricular assist devices","volume":"125","author":"Eckman","year":"2012","journal-title":"Circulation"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib20","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.healun.2013.11.001","article-title":"Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device","volume":"33","author":"Kirklin","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib21","first-page":"1423","article-title":"A multicenter analysis of clinical hemolysis in patients supported with durable, long-term left ventricular assist device therapy","author":"Katz","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib22","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1056\/NEJMoa1313385","article-title":"Unexpected abrupt increase in left ventricular assist device thrombosis","volume":"370","author":"Starling","year":"2014","journal-title":"N Engl J Med"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib23","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.healun.2013.10.005","article-title":"Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: A multifactorial phenomenon","volume":"33","author":"Uriel","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib24","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.healun.2013.05.002","article-title":"Algorithm for the diagnosis and management of suspected pump thrombus","volume":"32","author":"Goldstein","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib25","doi-asserted-by":"crossref","first-page":"1270","DOI":"10.1016\/j.athoracsur.2010.04.093","article-title":"Infectious complications in patients with left ventricular assist device: Etiology and outcomes in the continuous-flow era","volume":"90","author":"Topkara","year":"2010","journal-title":"Ann Thorac Surg"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib26","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1016\/j.healun.2014.04.010","article-title":"Sixth INTERMACS annual report: A 10,000-patient database","volume":"33","author":"Kirklin","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib27","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1016\/j.jtcvs.2007.12.077","article-title":"Low thromboembolic risk for patients with the HeartMate II left ventricular assist device","volume":"136","author":"John","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib28","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1016\/j.healun.2010.02.003","article-title":"Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy","volume":"29","author":"Slaughter","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib29","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1016\/j.healun.2009.05.018","article-title":"Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: Analysis of outpatient anti-coagulation","volume":"28","author":"Boyle","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib30","unstructured":"Prevention of HeartMate II pump thrombosis (PREVENT). Clinical trials.gov."},{"key":"10.1053\/j.semtcvs.2016.05.013_bib31","doi-asserted-by":"crossref","first-page":"2097","DOI":"10.1016\/j.athoracsur.2014.02.041","article-title":"Hemolysis, pump thrombus, and neurologic events in continuous-flow left ventricular assist device recipients","volume":"97","author":"Whitson","year":"2014","journal-title":"Ann Thorac Surg"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib32","unstructured":"\u3008www.cms.gov\/medicare-coverage\u3009"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib33","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.jchf.2014.11.006","article-title":"Echocardiographic ramp test for continuous-flow left ventricular assist devices: Do loading conditions matter?","volume":"4","author":"Adatya","year":"2015","journal-title":"JACC Heart Fail"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib34","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.jtcvs.2015.09.052","article-title":"Adverse event burden and mechanical circulatory support: Looking toward the future","volume":"151","author":"Pagani","year":"2016","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1053\/j.semtcvs.2016.05.013_bib35","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1016\/j.jtcvs.2012.05.044","article-title":"Long-term mechanical circulatory support (destination therapy): On track to compete with heart transplantation","volume":"144","author":"Kirklin","year":"2012","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["Seminars in Thoracic and Cardiovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1043067916300594?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1043067916300594?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,11]],"date-time":"2018-09-11T06:57:11Z","timestamp":1536649031000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1043067916300594"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016]]},"references-count":35,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016]]}},"alternative-id":["S1043067916300594"],"URL":"https:\/\/doi.org\/10.1053\/j.semtcvs.2016.05.013","relation":{},"ISSN":["1043-0679"],"issn-type":[{"value":"1043-0679","type":"print"}],"subject":[],"published":{"date-parts":[[2016]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A Decade of Experience With Continuous-Flow Left Ventricular Assist Devices","name":"articletitle","label":"Article Title"},{"value":"Seminars in Thoracic and Cardiovascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1053\/j.semtcvs.2016.05.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}