{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T05:35:02Z","timestamp":1782970502666,"version":"3.54.5"},"reference-count":30,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Seminars in Ultrasound, CT and MRI"],"published-print":{"date-parts":[[2021,6]]},"DOI":"10.1053\/j.sult.2021.04.007","type":"journal-article","created":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T11:56:20Z","timestamp":1619092580000},"page":"307-315","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["\u201cThe Pituitary within GRASP\u201d \u2013 Golden-Angle Radial Sparse Parallel Dynamic MRI Technique and Applications to the Pituitary Gland"],"prefix":"10.1053","volume":"42","author":[{"given":"Matthew D.","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew G.","family":"Young","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Girish M.","family":"Fatterpekar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1053\/j.sult.2021.04.007_bib0001","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1007\/s11060-013-1307-z","article-title":"State of art imaging of the pituitary tumors","volume":"117","author":"Patronas","year":"2014","journal-title":"J Neurooncol"},{"key":"10.1053\/j.sult.2021.04.007_bib0002","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1016\/j.ejmp.2014.04.005","article-title":"A review of technical aspects of T1-weighted dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in human brain tumors","volume":"30","author":"Bergamino","year":"2014","journal-title":"Physica Med."},{"key":"10.1053\/j.sult.2021.04.007_bib0003","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1177\/000313481908500630","article-title":"Meta-analysis of quantitative dynamic contrast-enhanced MRI for the assessment of neoadjuvant chemotherapy in breast cancer","volume":"85","author":"Jun","year":"2019","journal-title":"Am Surg"},{"key":"10.1053\/j.sult.2021.04.007_bib0004","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0227031","article-title":"The role of gadolinium in magnetic resonance imaging for early prostate cancer diagnosis: A diagnostic accuracy study","volume":"14","author":"Cosma","year":"2019","journal-title":"PLoS One"},{"key":"10.1053\/j.sult.2021.04.007_bib0005","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.1016\/j.rcl.2020.07.009","article-title":"Neuroimaging of the Pituitary Gland","volume":"58","author":"Chapman","year":"2020","journal-title":"Radiol. Clin. North Am."},{"key":"10.1053\/j.sult.2021.04.007_bib0006","first-page":"965","article-title":"Dynamic and conventional spin-echo MR of pituitary microlesions","volume":"18","author":"Bartynski","year":"1997","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1053\/j.sult.2021.04.007_bib0007","doi-asserted-by":"crossref","first-page":"671","DOI":"10.2214\/ajr.163.3.8079866","article-title":"Detection of pituitary microadenomas: comparison of dynamic keyhole fast spin-echo, unenhanced, and conventional contrast-enhanced MR imaging","volume":"163","author":"Kucharczyk","year":"1994","journal-title":"Am J Roentgenol"},{"key":"10.1053\/j.sult.2021.04.007_bib0008","doi-asserted-by":"crossref","DOI":"10.1016\/j.beem.2019.05.002","article-title":"Modern imaging of pituitary adenomas","volume":"33","author":"Bashari","year":"2019","journal-title":"Best Prac Res Clin Endocrinol & Metabol"},{"key":"10.1053\/j.sult.2021.04.007_bib0009","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1148\/radiology.178.2.1987606","article-title":"Normal and abnormal pituitary glands: gadopentetate dimeglumine-enhanced MR imaging","volume":"178","author":"Sakamoto","year":"1991","journal-title":"Radiology"},{"key":"10.1053\/j.sult.2021.04.007_bib0010","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1109\/TMI.2006.885337","article-title":"An optimal radial profile order based on the golden ratio for time-resolved MRI","volume":"26","author":"Winkelmann","year":"2007","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1053\/j.sult.2021.04.007_bib0011","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/RLI.0b013e318271869c","article-title":"Free-breathing contrast-enhanced multiphase mri of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling","volume":"48","author":"Chandarana","year":"2013","journal-title":"Invest. Radiol."},{"key":"10.1053\/j.sult.2021.04.007_bib0012","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1097\/RLI.0b013e31821eea45","article-title":"Free-breathing radial 3D fat-suppressed t1-weighted gradient echo sequence: a viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration","volume":"46","author":"Chandarana","year":"2011","journal-title":"Invest. Radiol."},{"key":"10.1053\/j.sult.2021.04.007_bib0013","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20140863","article-title":"Evaluation of the orbit using contrast-enhanced radial 3D fat-suppressed T1 weighted gradient echo (Radial-VIBE) sequence","volume":"88","author":"Bangiyev","year":"2015","journal-title":"Br J Radiol"},{"key":"10.1053\/j.sult.2021.04.007_bib0014","doi-asserted-by":"crossref","first-page":"883","DOI":"10.2214\/AJR.13.11729","article-title":"Contrast-enhanced radial 3D fat-suppressed T1-weighted gradient-recalled echo sequence versus conventional fat-suppressed contrast-enhanced T1-weighted studies of the head and neck","volume":"203","author":"Wu","year":"2014","journal-title":"AJR Am J Roentgenol"},{"key":"10.1053\/j.sult.2021.04.007_bib0015","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.biosystems.2018.01.001","article-title":"Phi in physiology, psychology and biomechanics: The golden ratio between myth and science","volume":"165","author":"Iosa","year":"2018","journal-title":"Biosystems"},{"key":"10.1053\/j.sult.2021.04.007_bib0016","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1002\/mrm.22463","article-title":"Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI","volume":"64","author":"Otazo","year":"2010","journal-title":"Magn Reson Med"},{"key":"10.1053\/j.sult.2021.04.007_bib0017","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1007\/s00261-016-0881-x","article-title":"Detection of prostate cancer local recurrence following radical prostatectomy: assessment using a continuously acquired radial golden-angle compressed sensing acquisition","volume":"42","author":"Rosenkrantz","year":"2017","journal-title":"Abdom Radiol (NY)"},{"key":"10.1053\/j.sult.2021.04.007_bib0018","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.clinimag.2020.12.027","article-title":"Comparison of image quality of subtracted and nonsubtracted breath hold VIBE and free breathing GRASP in the evaluation of renal masses","volume":"74","author":"Huber","year":"2021","journal-title":"Clin Imaging"},{"key":"10.1053\/j.sult.2021.04.007_bib0019","doi-asserted-by":"crossref","first-page":"1746","DOI":"10.1002\/jmri.25530","article-title":"Comparison of conventional DCE-MRI and a novel golden-angle radial multicoil compressed sensing method for the evaluation of breast lesion conspicuity","volume":"45","author":"Heacock","year":"2017","journal-title":"J Magn Reson Imaging"},{"key":"10.1053\/j.sult.2021.04.007_bib0020","doi-asserted-by":"crossref","DOI":"10.1007\/s00330-020-07263-0","article-title":"Achieving high spatial and temporal resolution with perfusion MRI in the head and neck region using golden-angle radial sampling","author":"Tomppert","year":"2021","journal-title":"Eur Radiol"},{"key":"10.1053\/j.sult.2021.04.007_bib0021","doi-asserted-by":"crossref","first-page":"1444","DOI":"10.3174\/ajnr.A4324","article-title":"High-resolution DCE-MRI of the pituitary gland using radial k -space acquisition with compressed sensing reconstruction","volume":"36","author":"Rossi Espagnet","year":"2015","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1053\/j.sult.2021.04.007_bib0022","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1148\/radiology.187.3.8497646","article-title":"Pituitary microadenomas: early enhancement with dynamic CT\u2013implications of arterial blood supply and potential importance","volume":"187","author":"Bonneville","year":"1993","journal-title":"Radiology"},{"key":"10.1053\/j.sult.2021.04.007_bib0023","series-title":"Proceedings of the ASNR 52nd Annual Meeting","first-page":"120","article-title":"Novel permeability criteria to assess function of morphologically normal pituitary gland in patients with central endocrinologic disturbances","author":"Rossi Espagnet","year":"2014"},{"key":"10.1053\/j.sult.2021.04.007_bib0024","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1148\/radiol.10100504","article-title":"Idiopathic growth hormone deficiency in the morphologically normal pituitary gland is associated with perfusion delay","volume":"258","author":"Wang","year":"2011","journal-title":"Radiology"},{"key":"10.1053\/j.sult.2021.04.007_bib0025","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.mri.2019.03.015","article-title":"Golden-angle radial sparse parallel (GRASP) MRI in clinical routine detection of pituitary microadenomas: First experience and feasibility","volume":"60","author":"Hainc","year":"2019","journal-title":"Magn. Reson. Imaging"},{"key":"10.1053\/j.sult.2021.04.007_bib0026","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.3174\/ajnr.A5244","article-title":"Role of high-resolution dynamic contrast-enhanced mri with golden-angle radial sparse parallel reconstruction to identify the normal pituitary gland in patients with macroadenomas","volume":"38","author":"Sen","year":"2017","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1053\/j.sult.2021.04.007_bib0027","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1227\/01.NEU.0000325725.77132.90","article-title":"Pituitary hormonal loss and recovery after transsphenoidal adenoma removal","volume":"63","author":"Fatemi","year":"2008","journal-title":"Neurosurgery"},{"key":"10.1053\/j.sult.2021.04.007_bib0028","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.ecl.2014.11.003","volume":"44","author":"Glezer","year":"2015","journal-title":"Endocrinol Metab Clin North Am"},{"key":"10.1053\/j.sult.2021.04.007_bib0029","first-page":"439","article-title":"Hypophysitis: endocrinologic and dynamic MR findings","volume":"19","author":"Sato","year":"1998","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1053\/j.sult.2021.04.007_bib0030","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s11102-006-6598-z","article-title":"Lymphocytic hypophysitis: disease spectrum and approach to diagnosis and therapy","volume":"9","author":"Rivera","year":"2006","journal-title":"Pituitary"}],"container-title":["Seminars in Ultrasound, CT and MRI"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0887217121000305?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0887217121000305?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:24:33Z","timestamp":1760135073000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0887217121000305"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,6]]}},"alternative-id":["S0887217121000305"],"URL":"https:\/\/doi.org\/10.1053\/j.sult.2021.04.007","relation":{},"ISSN":["0887-2171"],"issn-type":[{"value":"0887-2171","type":"print"}],"subject":[],"published":{"date-parts":[[2021,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"\u201cThe Pituitary within GRASP\u201d \u2013 Golden-Angle Radial Sparse Parallel Dynamic MRI Technique and Applications to the Pituitary Gland","name":"articletitle","label":"Article Title"},{"value":"Seminars in Ultrasound, CT and MRI","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1053\/j.sult.2021.04.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}