{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,28]],"date-time":"2026-06-28T06:22:50Z","timestamp":1782627770375,"version":"3.54.5"},"reference-count":13,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2000,4,1]],"date-time":"2000-04-01T00:00:00Z","timestamp":954547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Hand Surgery"],"published-print":{"date-parts":[[2000,4]]},"abstract":"<jats:p>The construction of a goniometric glove is described. Each of the sensors in the glove was calibrated over a custom built metal hand using blocks of known angles as angular references. The digital data output from each sensor of the glove were converted into angular displacements at each joint. The glove was validated for consistency of measurement and accuracy over a custom built metal jig and in the human hand. The accuracy of the glove was found to be within the limits of traditional goniometry. It is proposed that goniometric gloves could be useful in the assessment of hand function.<\/jats:p>","DOI":"10.1054\/jhsb.1999.0360","type":"journal-article","created":{"date-parts":[[2002,9,17]],"date-time":"2002-09-17T20:07:47Z","timestamp":1032293267000},"page":"200-207","source":"Crossref","is-referenced-by-count":60,"title":["A Goniometric Glove for Clinical Hand Assessment"],"prefix":"10.1177","volume":"25","author":[{"given":"N. W.","family":"WILLIAMS","sequence":"first","affiliation":[{"name":"From the Department of Plastic Surgery, Northern General Hospital, the Department of Medical Physics and Clinical Engineering, Royal Hallamshire Hospital, the Department of Applied Mathematics, University of Sheffield, Sheffield and the Centre for Health and Medical Research, University of Teeside, Middlesbrough, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. M. T.","family":"PENROSE","sequence":"additional","affiliation":[{"name":"From the Department of Plastic Surgery, Northern General Hospital, the Department of Medical Physics and Clinical Engineering, Royal Hallamshire Hospital, the Department of Applied Mathematics, University of Sheffield, Sheffield and the Centre for Health and Medical Research, University of Teeside, Middlesbrough, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C. M.","family":"CADDY","sequence":"additional","affiliation":[{"name":"From the Department of Plastic Surgery, Northern General Hospital, the Department of Medical Physics and Clinical Engineering, Royal Hallamshire Hospital, the Department of Applied Mathematics, University of Sheffield, Sheffield and the Centre for Health and Medical Research, University of Teeside, Middlesbrough, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"BARNES","sequence":"additional","affiliation":[{"name":"From the Department of Plastic Surgery, Northern General Hospital, the Department of Medical Physics and Clinical Engineering, Royal Hallamshire Hospital, the Department of Applied Mathematics, University of Sheffield, Sheffield and the Centre for Health and Medical Research, University of Teeside, Middlesbrough, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D. R.","family":"HOSE","sequence":"additional","affiliation":[{"name":"From the Department of Plastic Surgery, Northern General Hospital, the Department of Medical Physics and Clinical Engineering, Royal Hallamshire Hospital, the Department of Applied Mathematics, University of Sheffield, Sheffield and the Centre for Health and Medical Research, University of Teeside, Middlesbrough, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"HARLEY","sequence":"additional","affiliation":[{"name":"From the Department of Plastic Surgery, Northern General Hospital, the Department of Medical Physics and Clinical Engineering, Royal Hallamshire Hospital, the Department of Applied Mathematics, University of Sheffield, Sheffield and the Centre for Health and Medical Research, University of Teeside, Middlesbrough, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2000,4,1]]},"reference":[{"key":"b1-10.1054_jhsb.1999.0360","doi-asserted-by":"publisher","DOI":"10.1016\/S0266-7681(95)80058-1"},{"key":"b2-10.1054_jhsb.1999.0360","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"b3-10.1054_jhsb.1999.0360","doi-asserted-by":"publisher","DOI":"10.1142\/0321"},{"key":"b4-10.1054_jhsb.1999.0360","first-page":"315","volume":"38","author":"Dent JA","year":"1993","journal-title":"Journal of the Royal College of Surgeons of Edinburgh"},{"key":"b5-10.1054_jhsb.1999.0360","unstructured":"GentileCTWallaceMAvalonTDGoodmanSFullerRHallTAngular displacement sensorsUnited States Patent5, 086, 7851992"},{"key":"b6-10.1054_jhsb.1999.0360","doi-asserted-by":"publisher","DOI":"10.1093\/ptj\/29.7.302"},{"key":"b7-10.1054_jhsb.1999.0360","first-page":"69","volume":"1","author":"Hurt SP","year":"1947","journal-title":"American Journal of Occupational Therapy"},{"key":"b8-10.1054_jhsb.1999.0360","doi-asserted-by":"publisher","DOI":"10.1145\/212430.212431"},{"key":"b9-10.1054_jhsb.1999.0360","doi-asserted-by":"publisher","DOI":"10.1016\/0141-5425(91)90062-C"},{"key":"b10-10.1054_jhsb.1999.0360","doi-asserted-by":"publisher","DOI":"10.1177\/030802267603900614"},{"key":"b11-10.1054_jhsb.1999.0360","doi-asserted-by":"publisher","DOI":"10.1177\/154193128903300517"},{"key":"b12-10.1054_jhsb.1999.0360","volume-title":"Research methods in physical activity","author":"Thomas JR","year":"1990","edition":"2"},{"key":"b13-10.1054_jhsb.1999.0360","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.1990.10.0411"}],"container-title":["Journal of Hand Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1054\/jhsb.1999.0360","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1054\/jhsb.1999.0360","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:41:09Z","timestamp":1777502469000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1054\/jhsb.1999.0360"}},"subtitle":["Construction, calibration and validation"],"short-title":[],"issued":{"date-parts":[[2000,4]]},"references-count":13,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2000,4]]}},"alternative-id":["10.1054\/jhsb.1999.0360"],"URL":"https:\/\/doi.org\/10.1054\/jhsb.1999.0360","relation":{},"ISSN":["0266-7681"],"issn-type":[{"value":"0266-7681","type":"print"}],"subject":[],"published":{"date-parts":[[2000,4]]}}}