{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T10:48:53Z","timestamp":1792061333829,"version":"4.4.0"},"reference-count":12,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2000,8,1]],"date-time":"2000-08-01T00:00:00Z","timestamp":965088000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Hand Surgery"],"published-print":{"date-parts":[[2000,8]]},"abstract":"<jats:p>We investigated the diagnostic value of two different ultrasound scanning methods for the early diagnosis of acute scaphoid fractures. Fifty-seven patients with ten scaphoid fractures were assessed within a week of injury. The accuracy of the ultrasound assessment was 84% and its specificity was 91%. However, its sensitivity was only 50%. We conclude that ultrasound examination is unreliable for the diagnosis of acute scaphoid fractures.<\/jats:p>","DOI":"10.1054\/jhsb.2000.0432","type":"journal-article","created":{"date-parts":[[2002,9,19]],"date-time":"2002-09-19T11:33:28Z","timestamp":1032435208000},"page":"369-371","source":"Crossref","is-referenced-by-count":35,"title":["Ultrasound for Diagnosis of Scaphoid Fractures"],"prefix":"10.1177","volume":"25","author":[{"given":"B.","family":"MUNK","sequence":"first","affiliation":[{"name":"From the Department of Orthopaedic Surgery and the Department of Radiology, Aarhus Amtssygehus, University Hospital of Aarhus, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"BOLVIG","sequence":"additional","affiliation":[{"name":"From the Department of Orthopaedic Surgery and the Department of Radiology, Aarhus Amtssygehus, University Hospital of Aarhus, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"KR\u00d8NER","sequence":"additional","affiliation":[{"name":"From the Department of Orthopaedic Surgery and the Department of Radiology, Aarhus Amtssygehus, University Hospital of Aarhus, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"CHRISTIANSEN","sequence":"additional","affiliation":[{"name":"From the Department of Orthopaedic Surgery and the Department of Radiology, Aarhus Amtssygehus, University Hospital of Aarhus, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"BORRIS","sequence":"additional","affiliation":[{"name":"From the Department of Orthopaedic Surgery and the Department of Radiology, Aarhus Amtssygehus, University Hospital of Aarhus, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"BOE","sequence":"additional","affiliation":[{"name":"From the Department of Orthopaedic Surgery and the Department of Radiology, Aarhus Amtssygehus, University Hospital of Aarhus, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2000,8,1]]},"reference":[{"key":"b1-10.1054_jhsb.2000.0432","first-page":"809","volume-title":"Green\u2019s operative hand surgery","author":"Amadio PC","year":"1998","edition":"4"},{"key":"b2-10.1054_jhsb.2000.0432","doi-asserted-by":"publisher","DOI":"10.1016\/0020-1383(82)90056-0"},{"key":"b3-10.1054_jhsb.2000.0432","doi-asserted-by":"publisher","DOI":"10.1016\/S0009-9260(85)80329-9"},{"key":"b4-10.1054_jhsb.2000.0432","doi-asserted-by":"publisher","DOI":"10.1016\/0020-1383(91)90104-M"},{"key":"b5-10.1054_jhsb.2000.0432","doi-asserted-by":"publisher","DOI":"10.1136\/emj.5.2.97"},{"key":"b6-10.1054_jhsb.2000.0432","doi-asserted-by":"publisher","DOI":"10.1016\/S0009-9260(05)81108-0"},{"key":"b7-10.1054_jhsb.2000.0432","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198466040-00003"},{"key":"b8-10.1054_jhsb.2000.0432","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(90)90133-O"},{"key":"b9-10.1054_jhsb.2000.0432","doi-asserted-by":"publisher","DOI":"10.3109\/17453679508995561"},{"key":"b10-10.1054_jhsb.2000.0432","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198567030-00013"},{"key":"b11-10.1054_jhsb.2000.0432","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(87)90053-2"},{"key":"b12-10.1054_jhsb.2000.0432","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.124.1.25"}],"container-title":["Journal of Hand Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1054\/jhsb.2000.0432","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1054\/jhsb.2000.0432","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:41:17Z","timestamp":1777502477000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1054\/jhsb.2000.0432"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,8]]},"references-count":12,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2000,8]]}},"alternative-id":["10.1054\/jhsb.2000.0432"],"URL":"https:\/\/doi.org\/10.1054\/jhsb.2000.0432","relation":{},"ISSN":["0266-7681"],"issn-type":[{"value":"0266-7681","type":"print"}],"subject":[],"published":{"date-parts":[[2000,8]]}}}