{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,3]],"date-time":"2026-05-03T23:59:05Z","timestamp":1777852745868,"version":"3.51.4"},"reference-count":14,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2001,2,1]],"date-time":"2001-02-01T00:00:00Z","timestamp":980985600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Hand Surgery"],"published-print":{"date-parts":[[2001,2]]},"abstract":"<jats:p>This study evaluated the compressive capabilities of the 3.0mm Synthes cannulated screw and threaded washer. A transverse osteotomy was performed at the waist of eight cadaveric scaphoids and a custom-designed load cell was inserted before internal fixion with a 3.0mm cannulated screw and threaded washer. The mean intrascaphoid compression achieved was 108 (SD, 60) N. This compressive force is comparable to that produced by standard cortical screws.<\/jats:p>","DOI":"10.1054\/jhsb.2000.0481","type":"journal-article","created":{"date-parts":[[2002,9,19]],"date-time":"2002-09-19T11:33:28Z","timestamp":1032435208000},"page":"22-24","source":"Crossref","is-referenced-by-count":15,"title":["A Biomechanical Analysis of Intrascaphoid Compression Using the 3.00 mm Synthes Cannulated Screw and Threaded Washer: an in vitro Cadaveric Study"],"prefix":"10.1177","volume":"26","author":[{"given":"I. K. Y.","family":"LO","sequence":"first","affiliation":[{"name":"From the Bioengineering Research Laboratory, Hand and Upper Limb Centre, St Joseph\u2019s Health Centre, London Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G. J. W.","family":"KING","sequence":"additional","affiliation":[{"name":"From the Bioengineering Research Laboratory, Hand and Upper Limb Centre, St Joseph\u2019s Health Centre, London Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. D.","family":"PATTERSON","sequence":"additional","affiliation":[{"name":"From the Bioengineering Research Laboratory, Hand and Upper Limb Centre, St Joseph\u2019s Health Centre, London Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. A.","family":"JOHNSON","sequence":"additional","affiliation":[{"name":"From the Bioengineering Research Laboratory, Hand and Upper Limb Centre, St Joseph\u2019s Health Centre, London Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. G.","family":"CHESS","sequence":"additional","affiliation":[{"name":"From the Bioengineering Research Laboratory, Hand and Upper Limb Centre, St Joseph\u2019s Health Centre, London Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2001,2,1]]},"reference":[{"key":"b1-10.1054_jhsb.2000.0481","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(88)90267-5"},{"key":"b2-10.1054_jhsb.2000.0481","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100090507"},{"key":"b3-10.1054_jhsb.2000.0481","doi-asserted-by":"crossref","first-page":"195","DOI":"10.3928\/0147-7447-19890101-21","volume":"12","author":"Ender HG","year":"1989","journal-title":"Orthopaedics"},{"key":"b4-10.1054_jhsb.2000.0481","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-196547020-00002"},{"key":"b5-10.1054_jhsb.2000.0481","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.66B1.6693468"},{"key":"b6-10.1054_jhsb.2000.0481","doi-asserted-by":"publisher","DOI":"10.1016\/S0266-7681(05)80265-7"},{"key":"b7-10.1054_jhsb.2000.0481","volume-title":"Scaphoid fractures and complications","author":"Herndon JH","year":"1994"},{"key":"b8-10.1054_jhsb.2000.0481","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/S0363-5023(98)80115-9","volume":"23","author":"Lo IKY","year":"1998","journal-title":"Journal of Hand Surgery"},{"key":"b9-10.1054_jhsb.2000.0481","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(88)90178-7"},{"key":"b10-10.1054_jhsb.2000.0481","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(87)90054-4"},{"key":"b11-10.1054_jhsb.2000.0481","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(10)80059-0"},{"key":"b12-10.1054_jhsb.2000.0481","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(87)80002-3"},{"key":"b13-10.1054_jhsb.2000.0481","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(10)80058-9"},{"key":"b14-10.1054_jhsb.2000.0481","first-page":"30","volume":"230","author":"Szabo RM","year":"1988","journal-title":"Clinical Orthopaedics and Related Research"}],"container-title":["Journal of Hand Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1054\/jhsb.2000.0481","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1054\/jhsb.2000.0481","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:41:29Z","timestamp":1777502489000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1054\/jhsb.2000.0481"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,2]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2001,2]]}},"alternative-id":["10.1054\/jhsb.2000.0481"],"URL":"https:\/\/doi.org\/10.1054\/jhsb.2000.0481","relation":{},"ISSN":["0266-7681"],"issn-type":[{"value":"0266-7681","type":"print"}],"subject":[],"published":{"date-parts":[[2001,2]]}}}