{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,3]],"date-time":"2026-05-03T23:59:20Z","timestamp":1777852760223,"version":"3.51.4"},"reference-count":15,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2001,8,1]],"date-time":"2001-08-01T00:00:00Z","timestamp":996624000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Hand Surgery"],"published-print":{"date-parts":[[2001,8]]},"abstract":"<jats:p>We report a series of scaphoid fractures fixed with titanium alloy Herbert screws in which postoperative Magnetic Resonance Imaging (MRI) was used to assess the marrow signal in the proximal pole of the scaphoid and thus detect the presence of avascular necrosis. The artefact produced by the titanium alloy Herbert screw did not preclude this assessment.<\/jats:p>","DOI":"10.1054\/jhsb.2001.0585","type":"journal-article","created":{"date-parts":[[2002,9,19]],"date-time":"2002-09-19T11:33:28Z","timestamp":1032435208000},"page":"326-329","source":"Crossref","is-referenced-by-count":7,"title":["MRI Assessment of the Proximal Pole of the Scaphoid after Internal Fixation with a Titanium Alloy Herbert Screw"],"prefix":"10.1177","volume":"26","author":[{"given":"M.","family":"GANAPATHI","sequence":"first","affiliation":[{"name":"From the Royal Gwent Hospital, Newport, Gwent, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"SAVAGE","sequence":"additional","affiliation":[{"name":"From the Royal Gwent Hospital, Newport, Gwent, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A. R.","family":"JONES","sequence":"additional","affiliation":[{"name":"From the Royal Gwent Hospital, Newport, Gwent, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2001,8]]},"reference":[{"key":"e_1_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.166.1.3336682"},{"key":"e_1_2_1_3_1","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1080\/02841859809172153","article-title":"Aneurysm clip MR artefacts: titanium versus stainless steel and influence of imaging parameters","volume":"39","author":"Burtscher IM","year":"1998","unstructured":"BurtscherIMOwmanTRomnerBSt\u00e5hlbergFHolt\u00e5sSAneurysm clip MR artefacts: titanium versus stainless steel and influence of imaging parametersActa Radiologica1998397076","journal-title":"Acta Radiologica"},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.174.1.1740141"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199710000-00019"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(85)80191-X"},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s002340050824"},{"key":"e_1_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/00002142-199908000-00006"},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2008-1052223"},{"key":"e_1_2_1_10_1","first-page":"294","article-title":"Postoperative magnetic resonance imaging evaluation of Pipkin fractures fixated with titanium implants: a report of two cases","volume":"26","author":"Olscamp AJ","year":"1997","unstructured":"OlscampAJTaoSSSavolaineEREbraheimNAPostoperative magnetic resonance imaging evaluation of Pipkin fractures fixated with titanium implants: a report of two casesAmerican Journal of Orthopaedics199726294297","journal-title":"American Journal of Orthopaedics"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(91)90018-7"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0266-7681(98)80028-4"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.171.5.9798849"},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1177\/107110079601701205"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(09)90015-6"},{"key":"e_1_2_1_16_1","first-page":"939","article-title":"Aneurysm clips made of titanium: magnetic characteristics and artefacts in MR","volume":"18","author":"Wichmann W","year":"1997","unstructured":"WichmannWAmmonKVFinkUWeikTYasargilGMAneurysm clips made of titanium: magnetic characteristics and artefacts in MRAmerican Journal of Neuroradiology199718939994","journal-title":"American Journal of Neuroradiology"}],"container-title":["Journal of Hand Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1054\/jhsb.2001.0585","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1054\/jhsb.2001.0585","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:41:44Z","timestamp":1777502504000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1054\/jhsb.2001.0585"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,8]]},"references-count":15,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2001,8]]}},"alternative-id":["10.1054\/jhsb.2001.0585"],"URL":"https:\/\/doi.org\/10.1054\/jhsb.2001.0585","relation":{},"ISSN":["0266-7681"],"issn-type":[{"value":"0266-7681","type":"print"}],"subject":[],"published":{"date-parts":[[2001,8]]}}}