{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T13:11:45Z","timestamp":1779887505350,"version":"3.53.1"},"reference-count":13,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2002,4,1]],"date-time":"2002-04-01T00:00:00Z","timestamp":1017619200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Hand Surgery"],"published-print":{"date-parts":[[2002,4]]},"abstract":"<jats:p>Metal implants produce susceptibility artefacts in magnetic resonance imaging. We have explored the effects of scaphoid screw characteristics and orientation on MR susceptibility artefact. Titanium alloy, smallness and longitudinal alignment with the z-axis of the main magnetic field reduce the size of the susceptibility artefact.<\/jats:p>","DOI":"10.1054\/jhsb.2001.0717","type":"journal-article","created":{"date-parts":[[2002,9,19]],"date-time":"2002-09-19T11:33:28Z","timestamp":1032435208000},"page":"165-170","source":"Crossref","is-referenced-by-count":35,"title":["MRI Susceptibility Artefacts Related to Scaphoid Screws: the Effect of Screw Type, Screw Orientation and Imaging Parameters"],"prefix":"10.1177","volume":"27","author":[{"given":"M.","family":"GANAPATHI","sequence":"first","affiliation":[{"name":"From the Royal Gwent Hospital, Newport, Gwent, UK and University Hospital of Wales, Heath Park, Cardiff, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"JOSEPH","sequence":"additional","affiliation":[{"name":"From the Royal Gwent Hospital, Newport, Gwent, UK and University Hospital of Wales, Heath Park, Cardiff, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"SAVAGE","sequence":"additional","affiliation":[{"name":"From the Royal Gwent Hospital, Newport, Gwent, UK and University Hospital of Wales, Heath Park, Cardiff, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. R.","family":"JONES","sequence":"additional","affiliation":[{"name":"From the Royal Gwent Hospital, Newport, Gwent, UK and University Hospital of Wales, Heath Park, Cardiff, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B.","family":"TIMMS","sequence":"additional","affiliation":[{"name":"From the Royal Gwent Hospital, Newport, Gwent, UK and University Hospital of Wales, Heath Park, Cardiff, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"LYONS","sequence":"additional","affiliation":[{"name":"From the Royal Gwent Hospital, Newport, Gwent, UK and University Hospital of Wales, Heath Park, Cardiff, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2002,4]]},"reference":[{"key":"e_1_2_1_2_1","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1080\/02841859809172153","article-title":"Aneurysm clip MR artefacts: titanium versus stainless steel and influence of imaging parameters","volume":"39","author":"Burtscher IM","year":"1998","unstructured":"BurtscherIMOwmanTRomnerBSt\u00e5hlbergFHolt\u00e5sSAneurysm clip MR artefacts: titanium versus stainless steel and influence of imaging parametersActa Radiologica1998397076","journal-title":"Acta Radiologica"},{"key":"e_1_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.174.1.1740141"},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0009-9260(97)80250-4"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(85)80191-X"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1007\/s002340050824"},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2008-1052223"},{"key":"e_1_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(91)90018-7"},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0266-7681(98)80028-4"},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.209.2.9807590"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.171.5.9798849"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(09)90015-6"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.215.1.r00ap11254"},{"key":"e_1_2_1_14_1","first-page":"939","article-title":"Aneurysm clips made of titanium: magnetic characteristics and artefacts in MR","volume":"18","author":"Wichmann W","year":"1997","unstructured":"WichmannWAmmonKVFinkUWeikTYasargilGMAneurysm clips made of titanium: magnetic characteristics and artefacts in MRAmerican Journal of Neuroradiology199718939994","journal-title":"American Journal of Neuroradiology"}],"container-title":["Journal of Hand Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1054\/JHSB.2001.0717","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1054\/JHSB.2001.0717","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:42:05Z","timestamp":1777502525000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1054\/JHSB.2001.0717"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,4]]},"references-count":13,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2002,4]]}},"alternative-id":["10.1054\/JHSB.2001.0717"],"URL":"https:\/\/doi.org\/10.1054\/jhsb.2001.0717","relation":{},"ISSN":["0266-7681"],"issn-type":[{"value":"0266-7681","type":"print"}],"subject":[],"published":{"date-parts":[[2002,4]]}}}