{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,6]],"date-time":"2024-11-06T05:28:02Z","timestamp":1730870882251,"version":"3.28.0"},"reference-count":13,"publisher":"Georg Thieme Verlag KG","issue":"01","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Appl Clin Inform"],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Background\u2003When administering an infusion to a patient, it is necessary to verify that the infusion pump settings are in accordance with the injection orders provided by the physician. However, the infusion rate entered into the infusion pump by the health care provider cannot be automatically reconciled with the injection order information entered into the electronic medical records (EMRs). This is because of the difficulty in linking the infusion rate entered into the infusion pump by the health care provider with the injection order information entered into the EMRs.<\/jats:p><jats:p>\n          Objectives\u2003This study investigated a data linkage method for reconciling infusion pump settings with injection orders in the EMRs.<\/jats:p><jats:p>\n          Methods\u2003We devised and implemented a mechanism to convert injection order information into the Health Level 7 Fast Healthcare Interoperability Resources (FHIR), a new health information exchange standard, and match it with an infusion pump management system in a standard and simple manner using a REpresentational State Transfer (REST) application programming interface (API). The injection order information was extracted from Standardized Structured Medical Record Information Exchange version 2 International Organization for Standardization\/technical specification 24289:2021 and was converted to the FHIR format using a commercially supplied FHIR conversion module and our own mapping definition. Data were also sent to the infusion pump management system using the REST Web API.<\/jats:p><jats:p>\n          Results\u2003Information necessary for injection implementation in hospital wards can be transferred to FHIR and linked. The infusion pump management system application screen allowed the confirmation that the two pieces of information matched, and it displayed an error message if they did not.<\/jats:p><jats:p>\n          Conclusion\u2003Using FHIR, the data linkage between EMRs and infusion pump management systems can be smoothly implemented. We plan to develop a new mechanism that contributes to medical safety through the actual implementation and verification of this matching system.<\/jats:p>","DOI":"10.1055\/s-0043-1776699","type":"journal-article","created":{"date-parts":[[2024,1,3]],"date-time":"2024-01-03T23:30:23Z","timestamp":1704324623000},"page":"001-009","source":"Crossref","is-referenced-by-count":0,"title":["Mapping Injection Order Messages to Health Level 7 Fast Healthcare Interoperability Resources to Collate Infusion Pump Data"],"prefix":"10.1055","volume":"15","author":[{"given":"Shunsuke","family":"Doi","sequence":"additional","affiliation":[{"name":"Department of Healthcare Information Management, The University of Tokyo Hospital, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinichiroh","family":"Yokota","sequence":"additional","affiliation":[{"name":"Department of Healthcare Information Management, The University of Tokyo Hospital, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yugo","family":"Nagae","sequence":"additional","affiliation":[{"name":"Department of Healthcare Information Management, The University of Tokyo Hospital, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koichi","family":"Takahashi","sequence":"additional","affiliation":[{"name":"Medical Instruments Development and Technical Sales Department, Nipro Corporation, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mitsuhiro","family":"Aoki","sequence":"additional","affiliation":[{"name":"Software Development Division, Nipro System Software Engineering Corporation, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuhiko","family":"Ohe","sequence":"additional","affiliation":[{"name":"Graduate School of Medicine, The University of Tokyo, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2024,1,3]]},"reference":[{"issue":"04","key":"ref1","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1197\/jamia.M2616","article-title":"Workarounds to barcode medication administration systems: their occurrences, causes, and threats to patient safety","volume":"15","author":"R Koppel","year":"2008","journal-title":"J Am Med Inform Assoc"},{"issue":"06","key":"ref2","first-page":"65","article-title":"Five \u201crights\u201d equal 0 errors","volume":"54","author":"G H Sullivan","year":"1991","journal-title":"RN"},{"issue":"01","key":"ref5","doi-asserted-by":"crossref","first-page":"e10072","DOI":"10.1002\/lrh2.10072","article-title":"Development of a new seamless data stream from EMR to EDC system using SS-MIX2 standards applied for observational research in diabetes mellitus","volume":"3","author":"K Takenouchi","year":"2018","journal-title":"Learn Health Syst"},{"issue":"12","key":"ref7","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1007\/s40264-014-0232-1","article-title":"Benefits and risks of using smart pumps to reduce medication error rates: a systematic review","volume":"37","author":"K Ohashi","year":"2014","journal-title":"Drug Saf"},{"issue":"04","key":"ref8","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1055\/s-0042-1756428","article-title":"Uncovering discrepancies in IV vancomycin infusion records between pump logs and EHR documentation","volume":"13","author":"T H Tung","year":"2022","journal-title":"Appl Clin Inform"},{"issue":"03","key":"ref9","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1055\/s-0041-1730031","article-title":"Quantifying the impact of infusion alerts and alarms on nursing workflows: a retrospective analysis","volume":"12","author":"D Yu","year":"2021","journal-title":"Appl Clin Inform"},{"issue":"02","key":"ref10","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1055\/s-0040-1709508","article-title":"The impact of technology on prescribing errors in pediatric intensive care: a before and after study","volume":"11","author":"M M Howlett","year":"2020","journal-title":"Appl Clin Inform"},{"issue":"04","key":"ref11","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1055\/s-0040-1716527","article-title":"Direct observational study of interfaced smart-pumps in pediatric intensive care","volume":"11","author":"M M Howlett","year":"2020","journal-title":"Appl Clin Inform"},{"issue":"07","key":"ref16","doi-asserted-by":"crossref","first-page":"e21929","DOI":"10.2196\/21929","article-title":"The fast health interoperability resources (FHIR) standard: systematic literature review of implementations, applications, challenges and opportunities","volume":"9","author":"M Ayaz","year":"2021","journal-title":"JMIR Med Inform"},{"issue":"05","key":"ref17","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1093\/jamia\/ocv189","article-title":"SMART on FHIR: a standards-based, interoperable apps platform for electronic health records","volume":"23","author":"J C Mandel","year":"2016","journal-title":"J Am Med Inform Assoc"},{"key":"ref21","first-page":"587","article-title":"An investigation of message definition mappings between HL7 FHIR and SS-MIX2 standardized storage [in Japanese]","volume":"40","author":"K Tanaka","year":"2020","journal-title":"J Jpn Assoc Med Inform"},{"issue":"08","key":"ref22","doi-asserted-by":"crossref","first-page":"1796","DOI":"10.1093\/jamia\/ocab070","article-title":"Contemporary clinical decision support standards using Health Level Seven International Fast Healthcare Interoperability Resources","volume":"28","author":"H R Strasberg","year":"2021","journal-title":"J Am Med Inform Assoc"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"103188","DOI":"10.1016\/j.jbi.2019.103188","article-title":"Using HL7 FHIR to achieve interoperability in patient health record","volume":"94","author":"R Saripalle","year":"2019","journal-title":"J Biomed Inform"}],"container-title":["Applied Clinical Informatics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0043-1776699.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T14:02:10Z","timestamp":1730815330000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0043-1776699"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":13,"journal-issue":{"issue":"01","published-online":{"date-parts":[[2024,1,3]]},"published-print":{"date-parts":[[2024,1]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0043-1776699","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["1869-0327"],"issn-type":[{"type":"electronic","value":"1869-0327"}],"subject":[],"published":{"date-parts":[[2024,1]]}}}