{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T10:29:03Z","timestamp":1779359343466,"version":"3.51.4"},"reference-count":0,"publisher":"Georg Thieme Verlag KG","issue":"08","license":[{"start":{"date-parts":[[2020,7,21]],"date-time":"2020-07-21T00:00:00Z","timestamp":1595289600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Endosc Int Open"],"published-print":{"date-parts":[[2020,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Background\u2002During peroral endoscopic myotomy (POEM), use of traditional instruments leads to an increase in overall time of procedure due to constant exchange of instruments. Speedboat-RS2 (Creo-Medical, UK) is a novel device which has shown promising results for endoscopic submucosal dissection of gastrointestinal lesions, but its feasibility, and safety for POEM is unexplored.<\/jats:p><jats:p>\n          Methods\u2002Data from patients who had undergone POEM for achalasia cardia utilizing Speedboat-RS2 was reviewed.<\/jats:p><jats:p>\n          Results\u2002Two patients with mean age of 46 years and mean symptom duration of 3 years were included. Both patients had type II achalasia diagnosed on esophageal manometry. One patient underwent anterior myotomy and the other posterior approach. Submucosal tunneling (~15\u200acm) was achieved in a mean of 20 minutes, myotomy (~ 9\u200acm) in 8 minutes and the entire procedure was completed in a mean of 30 minutes with 100\u200a% technical success. Both patients were discharged the day after the procedure without any immediate adverse events. At 6 weeks, endoscopy was uneventful and the patients were asymptomatic.<\/jats:p><jats:p>\n          Conclusions\u2002Early experience shows that Speedboat-RS2 is feasible for performing POEM with good safety profile. Submucosal tunneling was relatively quick and coagulation was effective. Long term studies with a larger patient cohort are warranted.<\/jats:p>","DOI":"10.1055\/a-1165-0087","type":"journal-article","created":{"date-parts":[[2020,7,21]],"date-time":"2020-07-21T22:31:05Z","timestamp":1595370665000},"page":"E998-E1001","source":"Crossref","is-referenced-by-count":10,"title":["Feasibility of Speedboat RS2 with bipolar radiofrequency energy for peroral endoscopic myotomy in patients with achalasia (with video)"],"prefix":"10.1055","volume":"08","author":[{"given":"Gaurav","family":"Patil","sequence":"additional","affiliation":[{"name":"Baldota Institute of Digestive Sciences, Gleneagles Global Hospitals, Mumbai, Maharashtra, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anki","family":"Dalal","sequence":"additional","affiliation":[{"name":"Baldota Institute of Digestive Sciences, Gleneagles Global Hospitals, Mumbai, Maharashtra, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amit P.","family":"Maydeo","sequence":"additional","affiliation":[{"name":"Baldota Institute of Digestive Sciences, Gleneagles Global Hospitals, Mumbai, Maharashtra, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2020,7,21]]},"container-title":["Endoscopy International Open"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-1165-0087.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,21]],"date-time":"2020-07-21T22:31:06Z","timestamp":1595370666000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-1165-0087"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,21]]},"references-count":0,"journal-issue":{"issue":"08","published-online":{"date-parts":[[2020,7,21]]},"published-print":{"date-parts":[[2020,8]]}},"URL":"https:\/\/doi.org\/10.1055\/a-1165-0087","relation":{},"ISSN":["2364-3722","2196-9736"],"issn-type":[{"value":"2364-3722","type":"print"},{"value":"2196-9736","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,21]]}}}