{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T17:47:39Z","timestamp":1777571259296,"version":"3.51.4"},"reference-count":15,"publisher":"Georg Thieme Verlag KG","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Klin Monbl Augenheilkd"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title><jats:p>\n          Hintergrund Evaluierung des Einflusses von biometrischen Daten (Augenl\u00e4nge, Vorderkammertiefe) auf die Planung der Augenmuskeloperation mithilfe einer Simulationssoftware und\n\t\t\t\t\t\u201ePartial-least-Squares-Regression\u201c.<\/jats:p><jats:p>\n          Material und Methoden In diese retrospektive Studie wurden Patienten\/-innen eingeschlossen, bei denen auf einem Auge eine Augenmuskeloperation an einem oder beiden horizontalen\n\t\t\t\t\tAugenmuskeln stattgefunden hatte. Zus\u00e4tzlich wurde eine optische Biometrie durchgef\u00fchrt und der Schielwinkel in der Ferne vor und nach der Augenmuskeloperation gemessen. Im n\u00e4chsten Schritt\n\t\t\t\t\twurde die Operation mittels Simulationsprogramm (See++, RISC, \u00d6sterreich) mit und ohne axiale Augenl\u00e4nge simuliert und mit der tats\u00e4chlichen OP-Strecke verglichen. Im letzten Schritt wurde\n\t\t\t\t\tdann der Einfluss verschiedener anatomischer Parameter des operierten Auges auf den postoperativen Schielwinkel untersucht. Daf\u00fcr wurde zuerst eine Partial-least-Squares-Regression (variable\n\t\t\t\t\timportance of projection, VIP) und danach ein Boot-Strapping-Verfahren verwendet.<\/jats:p><jats:p>\n          Ergebnisse Insgesamt wurden 97 Patienten\/-innen in die Studie eingeschlossen, und 92 Datens\u00e4tze konnten analysiert werden. In allen F\u00e4llen wurde der Schielwinkel um mindestens 25%\n\t\t\t\t\treduziert und in 60% konnte eine Reduktion von mindestens 75% erreicht werden. Die Ber\u00fccksichtigung der Augenl\u00e4nge verbesserte die Simulation geringf\u00fcgig (0,3\u2009mm \u00c4nderung der\n\t\t\t\t\tOperationsstrecke, Standardabweichung: 1,65\u2009mm). Ein relevanter Einfluss konnte f\u00fcr die Faktoren pr\u00e4operativer Schielwinkel (VIP: 1,8), gefolgt von Vorderkammertiefe (VIP: 1,0) und Alter\n\t\t\t\t\t(VIP: 0,9) gezeigt werden. Signifikant h\u00f6her war er, verglichen zu einzelnen Parametern, bei der Ratio Vorderkammertiefe\/Augenl\u00e4nge.<\/jats:p><jats:p>\n          Schlussfolgerung Das verwendete Simulationsmodell konnte zeigen, dass die Verwendung der axialen Augenl\u00e4nge zu einer geringen Verbesserung der Planung der Augenmuskeloperation f\u00fchrt.\n\t\t\t\t\tEinen gr\u00f6\u00dferen Einfluss hatte allerdings die Ber\u00fccksichtigung der Ratio Vorderkammertiefe\/Augenl\u00e4nge.<\/jats:p>","DOI":"10.1055\/a-1699-2679","type":"journal-article","created":{"date-parts":[[2022,3,23]],"date-time":"2022-03-23T23:56:03Z","timestamp":1648079763000},"page":"1483-1488","source":"Crossref","is-referenced-by-count":2,"title":["Einfluss von biometrischen Daten auf die Planung der Augenmuskeloperation"],"prefix":"10.1055","volume":"239","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9596-4563","authenticated-orcid":false,"given":"Nino","family":"Hirnschall","sequence":"additional","affiliation":[{"name":"Ophthalmology, Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch-Krankenhaus, Wien, \u00d6sterreich"},{"name":"Department of Ophthalmology and Optometry, Kepler University Hospital GmbH, Johannes Kepler University Linz, \u00d6sterreich"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katharina","family":"Malek","sequence":"additional","affiliation":[{"name":"Ophthalmology, Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch-Krankenhaus, Wien, \u00d6sterreich"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Kaltofen","sequence":"additional","affiliation":[{"name":"Research Institute f\u00fcr Symbolic Computation \u2013 Software GmbH, Hagenberg, \u00d6sterreich"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siegfried","family":"Priglinger","sequence":"additional","affiliation":[{"name":"Institut Integriert Studieren, Johannes Kepler University Linz, \u00d6sterreich"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siegmund","family":"Priglinger","sequence":"additional","affiliation":[{"name":"Institut Integriert Studieren, Johannes Kepler University Linz, \u00d6sterreich"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annette","family":"Harrer","sequence":"additional","affiliation":[{"name":"Ophthalmology, Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch-Krankenhaus, Wien, \u00d6sterreich"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver","family":"Findl","sequence":"additional","affiliation":[{"name":"Ophthalmology, Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch-Krankenhaus, Wien, \u00d6sterreich"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerhard","family":"Partik","sequence":"additional","affiliation":[{"name":"Ophthalmology, Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch-Krankenhaus, Wien, \u00d6sterreich"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2022,3,23]]},"reference":[{"key":"ref1","volume-title":"Strabismus","author":"H Kaufmann","year":"2012","edition":"4. Aufl."},{"key":"ref2","first-page":"6","volume-title":"Augenmotilit\u00e4tsst\u00f6rungen: Computerunterst\u00fctzte Diagnose und Therapie","author":"S Priglinger","year":"2004"},{"key":"ref4","first-page":"R87","article-title":"[Basic principles of eye muscle surgery]","volume":"225","author":"J Fricke","year":"2008","journal-title":"Klin Monbl Augenheilkd"},{"key":"ref5","first-page":"281","article-title":"[Eye muscle surgery]","volume":"112","author":"H Steffen","year":"2015","journal-title":"Ophthalmologe"},{"key":"ref6","first-page":"68","article-title":"[Effect of bulbus length of reduction of squint angle after suture fixation]","volume":"91","author":"T Krzizok","year":"1994","journal-title":"Ophthalmologe"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1007\/s00417-020-04690-z","article-title":"Consideration of eyeball length and prismatic side-effects of spectacle lenses in strabismus surgery\u2013a randomised, double-blind interventional study","volume":"258","author":"F Beisse","year":"2020","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref8","first-page":"62","article-title":"[Effect of axial bulbus length and preoperative squint angle on the effect of horizontal combined squint operations]","volume":"91","author":"M Gr\u00e4f","year":"1994","journal-title":"Ophthalmologe"},{"key":"ref9","first-page":"305","article-title":"Virtual eye muscle surgery based upon biomechanical models","volume":"81","author":"H Mayr","year":"2001","journal-title":"Stud Health Technol Inform"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"5196","DOI":"10.1167\/iovs.13-11991","article-title":"Predicting the postoperative intraocular lens position using continuous intraoperative optical coherence tomography measurements","volume":"54","author":"N Hirnschall","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1136\/bjophthalmol-2013-304731","article-title":"Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation","volume":"99","author":"N Hirnschall","year":"2015","journal-title":"Br J Ophthalmol"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"257","DOI":"10.3928\/0191-3913-19960901-11","article-title":"Axial length estimation in strabismic patients","volume":"33","author":"B J Kushner","year":"1996","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"ref13","first-page":"206","article-title":"[Squint angle, eyeball length and surgical results in horizontal strabismus]","volume":"96","author":"A Broniarczyk-Loba","year":"1994","journal-title":"Klin Oczna"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1001\/archopht.1993.01090010079030","article-title":"Factors influencing response to strabismus surgery","volume":"111","author":"B J Kushner","year":"1993","journal-title":"Arch Ophthalmol"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1111\/j.1442-9071.2005.00970.x","article-title":"Simple formula for determining the location of the equator","volume":"33","author":"S Kim","year":"2005","journal-title":"Clin Exp Ophthalmol"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"6847","DOI":"10.1167\/iovs.15-17228","article-title":"Predicting Lens Diameter: Ocular Biometry With High-Resolution MRI","volume":"56","author":"K Erb-Eigner","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["Klinische Monatsbl\u00e4tter f\u00fcr Augenheilkunde"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-1699-2679.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,14]],"date-time":"2022-12-14T07:30:06Z","timestamp":1671003006000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-1699-2679"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,23]]},"references-count":15,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2022,12,9]]},"published-print":{"date-parts":[[2022,12]]}},"URL":"https:\/\/doi.org\/10.1055\/a-1699-2679","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0023-2165","1439-3999"],"issn-type":[{"value":"0023-2165","type":"print"},{"value":"1439-3999","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,23]]}}}