{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,6,29]],"date-time":"2024-06-29T12:10:14Z","timestamp":1719663014219},"reference-count":52,"publisher":"Georg Thieme Verlag KG","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Handchir Mikrochir Plast Chir"],"published-print":{"date-parts":[[2023,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The minimally invasive flexor carpi radialis approach can be used for\n                    volar locking plate fixation of distal radius fractures. It offers the advantage\n                    of preserving ligamentotaxis, which facilitates the reduction and the small size\n                    of the scar improves the esthetic result of the procedure. It is indicated for\n                    extra-articular fractures of the distal radius. In the case of an\n                    intra-articular fracture, an arthroscopy may be associated. In the case of a\n                    proximal diaphyseal extension of the fracture, a second proximal approach can be\n                    added in order to use a longer plate. Relative contraindications are comminuted\n                    articular fractures in elderly osteoporotic patients. Functional and\n                    radiological results are comparable to those obtained with the extented\n                        flexor carpi radialis approach. A conversion of the procedure for a\n                    larger incision is always possible in the case of a difficult reduction.<\/jats:p>","DOI":"10.1055\/a-1951-1585","type":"journal-article","created":{"date-parts":[[2023,1,30]],"date-time":"2023-01-30T23:57:28Z","timestamp":1675123048000},"page":"194-202","source":"Crossref","is-referenced-by-count":0,"title":["Technique, Indications and Limitations of a Minimally Invasive\n                    Approach to Treat Distal Radius Fractures and Malunions"],"prefix":"10.1055","volume":"55","author":[{"given":"Philippe","family":"Liverneaux","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laela El","family":"Amiri","sequence":"additional","affiliation":[{"name":"Department of Hand Surgery, Strasbourg University Hospitals, FMTS,\n                    avenue Moli\u00e8re, Strasbourg, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sybille","family":"Facca","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marie-C\u00e9cile","family":"Sapa","sequence":"additional","affiliation":[{"name":"Department of Hand Surgery, Strasbourg University Hospitals, FMTS,\n                    avenue Moli\u00e8re, Strasbourg, France"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2023,1,30]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1142\/s0218810400000223","article-title":"The treatment of unstable distal radius fractures with volar fixation","volume":"5","author":"J L Orbay","year":"2000","journal-title":"Hand Surg"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1053\/jhsu.2002.32081","article-title":"Volar fixation for dorsally displaced fractures of the distal radius: a\n                    preliminary report","volume":"27","author":"J L Orbay","year":"2002","journal-title":"J Hand Surg Am"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"1204","DOI":"10.1016\/j.injury.2012.04.002","article-title":"The extended flexor carpi radialis approach for partially healed malaligned\n                    fractures of the distal radius","volume":"43","author":"M M Wijffels","year":"2012","journal-title":"Injury"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"S80","DOI":"10.1016\/j.hansur.2016.02.011","article-title":"Outcomes of minimally invasive plate osteosynthesis (MIPO) with volar locking\n                    plates in distal radius fractures: A review","volume":"35S","author":"P Liverneaux","year":"2016","journal-title":"Hand Surg Rehabil"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1097\/00005131-198802030-00002","article-title":"Open reduction and internal fixation of volar lip fractures of the distal\n                    radius","volume":"2","author":"R S Smith","year":"1988","journal-title":"J Orthop Trauma"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"S39","DOI":"10.1016\/j.hansur.2016.03.007","article-title":"Surgical exposures for distal radius fractures","volume":"35S","author":"O Mares","year":"2016","journal-title":"Hand Surg Rehabil"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1097\/00130911-200112000-00004","article-title":"The extended flexor carpi radialis approach: a new perspective for the distal\n                    radius fracture","volume":"5","author":"J L Orbay","year":"2001","journal-title":"Tech Hand Up Extrem Surg"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"1364","DOI":"10.3928\/0147-7447-20051101-17","article-title":"The effect of an extended flexor carpi radialis approach on blood flow to the\n                    distal radius: a cadaveric study","volume":"28","author":"J D Placzek","year":"2005","journal-title":"Orthopedics"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"A20","DOI":"10.1016\/s0020-1383(97)90112-1","article-title":"Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in\n                    proximal and distal femoral fractures","volume":"28","author":"C Krettek","year":"1997","journal-title":"Injury"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"1964","DOI":"10.1016\/j.injury.2014.09.023","article-title":"Radiological assessment of the safe zone for medial minimally invasive plate\n                    osteosynthesis in the distal femur with computed tomography angiography","volume":"45","author":"J J Kim","year":"2014","journal-title":"Injury"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1007\/s00590-014-1539-4","article-title":"Minimally invasive percutaneous plate osteosynthesis for closed distal tibial\n                    fractures: a consecutive study based on 25 patients","volume":"25","author":"R Bhat","year":"2015","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1007\/s00590-013-1295-x","article-title":"Minimally invasive percutaneous plate osteosynthesis for ankle fractures: a\n                    prospective observational cohort study","volume":"24","author":"R E Pires","year":"2014","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"ref14","first-page":"335","article-title":"Case control study on open reduction internal fixation (ORIF) and minimally\n                    invasive percutaneous plate osteosynthesis (MIPPO) for the treatment of proximal\n                    humerus fractures in aged","volume":"28","author":"Y B Gao","year":"2015","journal-title":"Zhongguo Gu Shang"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"e7","DOI":"10.1016\/j.jse.2015.06.024","article-title":"Minimally invasive plate osteosynthesis for midshaft clavicular fractures using\n                    superior anatomic plating","volume":"25","author":"Y Zhang","year":"2016","journal-title":"J Shoulder Elbow Surg"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1590\/1413-78522014220601003","article-title":"Fracture of distal humerus: MIPO technique with visualization of the radial\n                    nerve","volume":"22","author":"D R Zogbi","year":"2014","journal-title":"Acta Ortop Bras"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"A42","DOI":"10.1016\/s0020-1383(97)90114-5","article-title":"Minimally invasive plate osteosynthesis of distal fractures of the tibia","volume":"28","author":"D L Helfet","year":"1997","journal-title":"Injury"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"B31","DOI":"10.1016\/j.injury.2003.09.023","article-title":"General principles for the clinical use of the LCP","volume":"34","author":"M Wagner","year":"2003","journal-title":"Injury"},{"key":"ref19","first-page":"577","article-title":"Distal radius fractures. Multiplanar ligamentotaxis","volume":"9","author":"J M Agee","year":"1993","journal-title":"Hand Clin"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1142\/s0218810400000193","article-title":"Percutaneous and limited open reduction of intra-articular distal radial\n                    fractures","volume":"5","author":"W B Geissler","year":"2000","journal-title":"Hand Surg"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1097\/BOT.0b013e3182008c83","article-title":"Clinical results of volar locking plate for distal radius fractures:\n                    conventional versus minimally invasive plate osteosynthesis","volume":"25","author":"Y Zenke","year":"2011","journal-title":"J Orthop Trauma"},{"key":"ref22","volume-title":"Internal Fixation of Small Fractures","author":"U Heim","year":"1987"},{"key":"ref23","first-page":"889","article-title":"A new cosmetic approach for volar \ufb01xed-angle plate \ufb01xation to\n                    treat distal radius fractures. J Jpn Soc Surg","volume":"24","author":"Y Yoshikawa","year":"2008","journal-title":"Hand"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"SA14","DOI":"10.1016\/s0020-1383(01)00057-2","article-title":"Minimally invasive reduction and osteosynthesis of articular fractures of the\n                    distal radius","volume":"32","author":"S F Duncan","year":"2001","journal-title":"Injury"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1016\/j.jhsb.2004.12.009","article-title":"Minimally invasive plate osteosynthesis for comminuted fractures of the\n                    metaphysis of the radius","volume":"30","author":"J Imatani","year":"2005","journal-title":"J Hand Surg Br"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1097\/BTH.0b013e3180cac281","article-title":"Minimally invasive plate osteosynthesis of distal radius fractures using a\n                    pronator sparing approach","volume":"12","author":"M K Sen","year":"2008","journal-title":"Tech Hand Up Extrem Surg"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1007\/s00776-013-0371","article-title":"Less invasive surgery with wrist arthroscopy for distal radius fracture","volume":"18","author":"Y Abe","year":"2013","journal-title":"J Orthop Sci"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.1007\/s00590-013-1364-1","article-title":"Distal radius fixation through a mini-invasive approach of 15 mm. Part 1:\n                    feasibility study","volume":"24","author":"A Zemirline","year":"2014","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"ref29","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.main.2013.12.006","article-title":"Technical note: How to spare the pronator quadratus during MIPO of distal radius\n                    fractures by using a mini-volar plate","volume":"33","author":"P B Rey","year":"2014","journal-title":"Chir Main"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1007\/s00590-013-1363-2","article-title":"Distal radius fixation through a mini-invasive approach of 15 mm. PART 1: a\n                    series of 144 cases","volume":"24","author":"F Lebailly","year":"2014","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"20","DOI":"10.4103\/0019-5413.125483","article-title":"Minimally invasive plate osteosynthesis for distal radius fractures","volume":"48","author":"X M Wei","year":"2014","journal-title":"Indian J Orthop"},{"key":"ref32","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1055\/s-0037-1599791","article-title":"Long Volar Plating for Metadiaphyseal Fractures of Distal Radius: Study\n                    Comparing Minimally Invasive Plate Osteosynthesis versus Conventional\n                    Approach","volume":"6","author":"E Pire","year":"2017","journal-title":"J Wrist Surg"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.otsr.2015.12.024","article-title":"Minimally invasive percutaneous plate osteosynthesis for distal radius fractures\n                    with long-segment metadiaphyseal comminution","volume":"102","author":"X M Wei","year":"2016","journal-title":"Orthop Traumatol Surg Res"},{"key":"ref34","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1055\/s-0034-1383103","article-title":"Ein neuer Zugang zur minimalinvasiven palmaren Plattenosteosynthese bei distaler\n                    Radiusfraktur","volume":"153","author":"M Chmielnicki","year":"2015","journal-title":"Z Orthop Unfall"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1007\/s00402-015-2162-5","article-title":"Clinical results of using minimally invasive long plate osteosynthesis versus\n                    conventional approach for extensive comminuted metadiaphyseal fractures of the\n                    radius","volume":"135","author":"C Y Chen","year":"2015","journal-title":"Arch Orthop Trauma Surg"},{"key":"ref36","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1016\/j.otsr.2017.01.002","article-title":"Is there a relevance of suction drainage in non-septic wrist surgery?","volume":"103","author":"G Pruni\u00e8res","year":"2017","journal-title":"Orthop Traumatol Surg Res"},{"key":"ref37","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1055\/s-0037-1620271","article-title":"Volar Locking Plate Fixation of Distal Radius Fractures: Splint versus Immediate\n                    Mobilization","volume":"7","author":"A Duprat","year":"2018","journal-title":"J Wrist Surg"},{"key":"ref38","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.otsr.2016.10.015","article-title":"Minimally invasive hardware removal after minimally invasive distal radius plate\n                    osteosynthesis (MIPO): Feasibility study in a 388 case series","volume":"103","author":"P Luigi Medda","year":"2017","journal-title":"Orthop Traumatol Surg Res"},{"key":"ref39","first-page":"903","article-title":"Internal fixation by double intrafocal plate. Functional treatment of non\n                    articular fractures of the lower end of the radius (author\u2019s\n                    transl)","volume":"30","author":"A Kapandji","year":"1976","journal-title":"Ann Chir"},{"key":"ref40","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1016\/j.otsr.2015.07.016","article-title":"Minimally invasive osteotomy for distal radius malunion: A preliminary series of\n                    9 cases","volume":"101","author":"C Taleb","year":"2015","journal-title":"Orthop Traumatol Surg Res"},{"key":"ref41","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1055\/s-0033-1359307","article-title":"Accuracy of 3D Virtual Planning of Corrective Osteotomies of the Distal\n                    Radius","volume":"2","author":"F Stockmans","year":"2013","journal-title":"J Wrist Surg"},{"key":"ref42","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1016\/j.hcl.2017.07.004","article-title":"Arthroscopic Management of Intra-articular Malunion in Fractures of the Distal\n                    Radius","volume":"33","author":"F Del Pi\u00f1al","year":"2017","journal-title":"Hand Clin"},{"key":"ref43","doi-asserted-by":"publisher","first-page":"193","DOI":"10.3928\/0147-7447-20040201-10","article-title":"The mini-incision hip: proceed with caution","volume":"27","author":"T S Thornhill","year":"2004","journal-title":"Orthopedics"},{"key":"ref44","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1097\/BTH.0000000000000118","article-title":"Possibility of Fixation of a Distal Radius Fracture With a Volar Locking Plate\n                    Through a 10 mm Approach","volume":"20","author":"K Naito","year":"2016","journal-title":"Tech Hand Up Extrem Surg"},{"key":"ref45","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1016\/j.hcl.2005.02.007","article-title":"Biomechanics and biology of external fixation of distal radius fractures","volume":"21","author":"R R Bindra","year":"2005","journal-title":"Hand Clin"},{"key":"ref46","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/s0753-9053(87)80011-x","article-title":"Intra-focal pinning of fractures of the distal end of the radius 10 years\n                    later","volume":"6","author":"A Kapandji","year":"1987","journal-title":"Ann Chir Main"},{"key":"ref47","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1016\/S0363-5023(98)80173-1","article-title":"Un-united fractures of the distal radius: a report of 12 cases","volume":"23","author":"K A Segalman","year":"1998","journal-title":"J Hand Surg Am"},{"key":"ref48","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1089\/ten.TEB.2009.0687","article-title":"The early fracture hematoma and its potential role in fracture healing","volume":"16","author":"P Kolar","year":"2010","journal-title":"Tissue Eng Part B Rev"},{"key":"ref49","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1097\/00130911-199706000-00002","article-title":"A minimally invasive distal radial osteotomy for treatment of distal radius\n                    fracture malunion","volume":"1","author":"S F Viegas","year":"1997","journal-title":"Tech Hand Up Extrem Surg"},{"key":"ref50","doi-asserted-by":"publisher","first-page":"93","DOI":"10.4103\/0019-5413.197555","article-title":"Distal radius fractures: Minimally invasive plate osteosynthesis with dorsal\n                    bicolumnar locking plates fixation","volume":"51","author":"A C Chen","year":"2017","journal-title":"Indian J Orthop"},{"key":"ref51","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1016\/j.main.2014.04.007","article-title":"Minimally invasive surgery of distal radius fractures: a series of 20 cases\n                    using a 15mm anterior approach and arthroscopy","volume":"33","author":"A Zemirline","year":"2014","journal-title":"Chir Main"},{"key":"ref52","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1142\/S0218810413720246","article-title":"Flexor pollicis longus tendon entrapment after performing minimally invasive\n                    plate osteosynthesis of a distal radius fracture: a case report","volume":"18","author":"Y C Chiu","year":"2013","journal-title":"Hand Surg"},{"key":"ref53","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1055\/s-0034-1394132","article-title":"The utility of the fluoroscopic skyline view during volar locking plate fixation\n                    of distal radius fractures","volume":"3","author":"L Vaiss","year":"2014","journal-title":"J Wrist Surg"}],"container-title":["Handchirurgie \u00b7 Mikrochirurgie \u00b7 Plastische Chirurgie"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-1951-1585.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,29]],"date-time":"2024-06-29T11:55:48Z","timestamp":1719662148000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-1951-1585"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,30]]},"references-count":52,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2023,6,12]]},"published-print":{"date-parts":[[2023,6]]}},"URL":"https:\/\/doi.org\/10.1055\/a-1951-1585","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0722-1819","1439-3980"],"issn-type":[{"value":"0722-1819","type":"print"},{"value":"1439-3980","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,30]]}}}