{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T13:52:17Z","timestamp":1784123537102,"version":"3.55.0"},"reference-count":15,"publisher":"Georg Thieme Verlag KG","issue":"04","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Klin Monbl Augenheilkd"],"published-print":{"date-parts":[[2023,4]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title><jats:p>\n          Hintergrund F\u00fcr Kataraktpatienten mit Astigmatismus ist das Einsetzen von torischen Intraokularlinsen eine sichere und effektive Methode, um eine Emmetropie zu erzielen. Dabei ist\n          die exakte Ausrichtung der Linse entlang der berechneten Achse essenziell f\u00fcr eine effektive Astigmatismuskorrektur. Das Ziel dieser Studie ist die Auswertung der Daten mittels deskriptiver\n          Statistik. Der prim\u00e4re Fokus liegt dabei auf den refraktiven Ergebnissen und somit der \u00dcberpr\u00fcfung der Ausrichtungsgenauigkeit von torischen IOL mit dem Zeiss Callisto-System.<\/jats:p><jats:p>\n          Patienten und Methoden F\u00fcr die Studie wurden insgesamt 106 Augen von 72 Patienten ausgewertet, die zwischen Januar 2019 und Dezember 2020 eine Kataraktoperation mit Implantation\n          einer torischen Intraokularlinse im Kantonsspital Winterthur erhalten haben. Die pr\u00e4operative Biometrie und intraoperative Markierung der Implantationsachse wurde mithilfe des Zeiss\n          Callisto-Systems durchgef\u00fchrt. Die postoperativen Kontrollen erfolgten nach 1 Tag, nach 1 Woche und nach 4 Wochen im Kantonsspital Winterthur oder beim zuweisenden Augenarzt. F\u00fcr die\n          Auswertung wurden nur die Daten der 4-w\u00f6chigen Kontrolle verwendet.<\/jats:p><jats:p>\n          Ergebnisse In 64 Augen (60%) wurde eine Zeiss AT Torbi 709\u2009M oder MP sowie in 42 Augen (40%) eine PhysIOL Ankoris toric yellow IOL implantiert. Bei 46 Augen wurde der postoperative\n          unkorrigierte Visus nicht erfasst. Von den \u00fcbrigen 60 Augen betrug der durchschnittliche postoperative unkorrigierte Visus 0,07\u2009\u00b1\u20090,12 logMAR. Dabei konnte bei 48% der Augen ein\n          postoperativer unkorrigierter Visus \u2265\u20091,0 (dezimal) und bei 92% ein Visus \u2265\u20090,6 (dezimal) erzielt werden. Der postoperative Zylinder betrug im Durchschnitt \u2212\u20090,65\u2009\u00b1\u20090,53\u2009dpt. Der Zylinder\n          der Zielrefraktion war durchschnittlich \u2212\u20090,45\u2009\u00b1\u20090,39\u2009dpt. Der Mittelwert des Betrags des postoperativen Zylinders abz\u00fcglich des Zylinders der Zielrefraktion war 0,42\u2009\u00b1\u20090,32\u2009dpt.<\/jats:p><jats:p>\n          Schlussfolgerungen Das Zeiss Callisto-System ist eine effektive Methode mit sehr guten klinischen Ergebnissen, um torische Intraokularlinsen entlang der Implantationsachse\n          auszurichten.<\/jats:p>","DOI":"10.1055\/a-2013-2466","type":"journal-article","created":{"date-parts":[[2023,4,25]],"date-time":"2023-04-25T22:42:48Z","timestamp":1682462568000},"page":"421-425","source":"Crossref","is-referenced-by-count":1,"title":["Refraktive Ergebnisse nach der Implantation torischer Intraokularlinsen mithilfe des Zeiss Callisto-Systems"],"prefix":"10.1055","volume":"240","author":[{"given":"Kenji","family":"Raemy","sequence":"additional","affiliation":[{"name":"Medizinische Fakult\u00e4t, Universit\u00e4t Z\u00fcrich, Z\u00fcrich, Schweiz"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Scherrer","sequence":"additional","affiliation":[{"name":"Augenklinik, Kantonsspital Winterthur, Winterthur, Schweiz"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J\u00f6rg Peter Egon","family":"St\u00fcrmer","sequence":"additional","affiliation":[{"name":"Augenklinik, Kantonsspital Winterthur, Winterthur, Schweiz"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2023,4,25]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.4103\/ijo.IJO_810_17","article-title":"Optimizing outcomes with toric intraocular lenses","volume":"65","author":"M Kaur","year":"2017","journal-title":"Indian J Ophthalmol"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"1479","DOI":"10.1016\/j.jcrs.2010.02.025","article-title":"Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes","volume":"36","author":"P C Hoffmann","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.ophtha.2015.10.002","article-title":"Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery: A Systematic Review and Meta-analysis","volume":"123","author":"L Kessel","year":"2016","journal-title":"Ophthalmology"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"1631","DOI":"10.1016\/j.jcrs.2008.04.041","article-title":"Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation","volume":"34","author":"J J Ma","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"125","DOI":"10.5935\/0004-2749.20140032","article-title":"Surgical management of astigmatism with toric intraocular lenses","volume":"77","author":"B V Ventura","year":"2014","journal-title":"Arq Bras Oftalmol"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1016\/s0886-3350(01)01279-2","article-title":"Cyclotorsion: a possible cause of residual astigmatism in refractive surgery","volume":"28","author":"M J Tjon-Fo-Sang","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"1792","DOI":"10.1016\/s0886-3350(00)00748-3","article-title":"Adhesion of fibronectin, vitronectin, laminin, and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyes. Part 1: histological sections","volume":"26","author":"R J Linnola","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1136\/bjophthalmol-2017-311797","article-title":"True rotational stability of a single-piece hydrophobic intraocular lens","volume":"103","author":"D Schartm\u00fcller","year":"2019","journal-title":"Br J Ophthalmol"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.ophtha.2017.07.004","article-title":"Incidence and Outcomes of Repositioning Surgery to Correct Misalignment of Toric Intraocular Lenses","volume":"125","author":"T Oshika","year":"2018","journal-title":"Ophthalmology"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"1340","DOI":"10.1016\/j.jcrs.2019.03.030","article-title":"Comparative meta-analysis of toric intraocular lens alignment accuracy in cataract patients: Image-guided system versus manual marking","volume":"45","author":"F Zhou","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"e1618","DOI":"10.1097\/md.0000000000001618","article-title":"Comparison Between Digital and Manual Marking for Toric Intraocular Lenses: A Randomized Trial","volume":"94","author":"A H Elhofi","year":"2015","journal-title":"Medicine (Baltimore)"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1016\/j.jcrs.2017.07.030","article-title":"Comparison of visual outcomes, alignment accuracy, and surgical time between 2 methods of corneal marking for toric intraocular lens implantation","volume":"43","author":"W J Mayer","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"747","DOI":"10.2147\/opth.s164175","article-title":"Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking","volume":"12","author":"J S Titiyal","year":"2018","journal-title":"Clin Ophthalmol"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1016\/j.jcrs.2017.03.041","article-title":"Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery","volume":"43","author":"V SC Webers","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1016\/j.jcrs.2015.12.052","article-title":"Accuracy of toric intraocular lens axis alignment using a 3-dimensional computer-guided visualization system","volume":"42","author":"I Montes de Oca","year":"2016","journal-title":"J Cataract Refract Surg"}],"container-title":["Klinische Monatsbl\u00e4tter f\u00fcr Augenheilkunde"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2013-2466.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,25]],"date-time":"2023-04-25T22:43:46Z","timestamp":1682462626000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2013-2466"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4]]},"references-count":15,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2023,4,25]]},"published-print":{"date-parts":[[2023,4]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2013-2466","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0023-2165","1439-3999"],"issn-type":[{"value":"0023-2165","type":"print"},{"value":"1439-3999","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4]]}}}