{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,5,2]],"date-time":"2024-05-02T10:52:50Z","timestamp":1714647170355},"reference-count":7,"publisher":"Georg Thieme Verlag KG","issue":"04","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Klin Monbl Augenheilkd"],"published-print":{"date-parts":[[2023,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Background This study is a retrospective analysis to compare ocular biometry measurements of axial length in children with myopia using Myopia Master (OCULUS, Wetzlar, Germany) and\n          Lenstar LS900 (HAAG-STREIT AG, K\u00f6niz, Switzerland).<\/jats:p><jats:p>\n          Patients and Methods Axial length measurements obtained with both instruments within a 3-week period were collected retrospectively. Measurements were visualized with a Bland-Altman\n          plot. For statistical evaluation, a paired t-test was applied, and the Pearson correlation coefficient (r) was established.<\/jats:p><jats:p>\n          Results Sixty-one eyes from 31 myopic patients (59% male, 41% female) with a mean age of 11.34\u2009\u00b1\u20093.25 years (range: 6\u200a\u2013\u200a18 years) were identified. Mean axial length was 24.7\u2009mm (SD\n          1.29) with the Myopia Master and 24.69\u2009mm (SD 1.30) with the Lenstar LS900 (Pearson correlation: r\u2009=\u20090.9991). The average difference of the axial length measurement between the two biometers\n          was 0.00\u200a064\u2009mm\u2009\u00b1\u20090.056\u2009SD (p\u2009=\u20090.9293).<\/jats:p><jats:p>\n          Conclusion The axial length measured by Myopia Master and Lenstar LS900 did not differ significantly. Thus, previous values obtained with the Lenstar LS900 can be applied to assess\n          myopia progression.<\/jats:p>","DOI":"10.1055\/a-2013-2557","type":"journal-article","created":{"date-parts":[[2023,4,25]],"date-time":"2023-04-25T22:42:48Z","timestamp":1682462568000},"page":"587-590","source":"Crossref","is-referenced-by-count":1,"title":["Retrospective Comparison of the Myopia Master and the Lenstar LS900 Axial Length Measurements in Children with Myopia"],"prefix":"10.1055","volume":"240","author":[{"given":"Thibika","family":"Sivakumar","sequence":"additional","affiliation":[{"name":"University of Basel, University Eye Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anja","family":"Palmowski-Wolfe","sequence":"additional","affiliation":[{"name":"University of Basel, University Eye Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2023,4,25]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1016\/j.preteyeres.2012.06.004","article-title":"The complex interactions of retinal, optical and environmental factors in myopia aetiology","volume":"31","author":"D I Flitcroft","year":"2012","journal-title":"Prog Retin Eye Res"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1001\/jamaophthalmol.2016.4009","article-title":"Association of Axial Length With Risk of Uncorrectable Visual Impairment for Europeans With Myopia","volume":"134","author":"J W Tideman","year":"2016","journal-title":"JAMA Ophthalmol"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"43414","DOI":"10.1038\/srep43414","article-title":"Meta-analysis of optical low-coherence reflectometry versus partial coherence interferometry biometry","volume":"7","author":"J Huang","year":"2017","journal-title":"Sci Rep"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"802","DOI":"10.1097\/j.jcrs.0000000000000551","article-title":"Ocular biometry with swept-source optical coherence tomography","volume":"47","author":"R Mont\u00e9s-Mic\u00f3","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"115","DOI":"10.3928\/1081597x-20190109-01","article-title":"Comprehensive Comparison of Axial Length Measurement With Three Swept-Source OCT-Based Biometers and Partial Coherence Interferometry","volume":"35","author":"J Huang","year":"2019","journal-title":"J Refract Surg"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1186\/s12886-022-02672-9","article-title":"Accuracy of axial length, keratometry, and refractive measurement with Myopia Master in children with ametropia","volume":"22","author":"Y Ye","year":"2022","journal-title":"BMC Ophthalmol"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1016\/j.clae.2017.03.007","article-title":"Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements","volume":"40","author":"S Sel","year":"2017","journal-title":"Cont Lens Anterior Eye"}],"container-title":["Klinische Monatsbl\u00e4tter f\u00fcr Augenheilkunde"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2013-2557.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,18]],"date-time":"2023-07-18T23:01:37Z","timestamp":1689721297000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2013-2557"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4]]},"references-count":7,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2023,4,25]]},"published-print":{"date-parts":[[2023,4]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2013-2557","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0023-2165","1439-3999"],"issn-type":[{"value":"0023-2165","type":"print"},{"value":"1439-3999","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4]]}}}