{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T16:28:06Z","timestamp":1747326486982,"version":"3.28.0"},"reference-count":22,"publisher":"Georg Thieme Verlag KG","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Z Gastroenterol"],"published-print":{"date-parts":[[2024,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n            Background Motorized spiral enteroscopy (MSE) is a recent modality for diagnostic and therapeutic examination of the small bowel using a spiral-shaped overtube with an integrated electric motor attached to an endoscope. With growing evidence of its efficacy, MSE is increasingly being used by endoscopic facilities. We herein present an uncommon case of the detachment of the spiral overtube from the endoscope during MSE.<\/jats:p><jats:p>\n            Case Report We performed antegrade MSE in a 75-year-old female under general anesthesia for coagulation of multiple small-bowel arteriovenous malformations and resection of a polyp detected on a previous capsule endoscopy. The management was successful, and we had no passage difficulties. However, during the withdrawal phase of the enteroscope, the entire spiral overtube disconnected from the endoscopic shaft and became stuck in the esophagus and pharynx. Attempts to remove the lodged spiral using various endoscopic forceps, graspers, snares, or a dilatation balloon failed. Also, the laryngoscopic use of Magill forceps did not allow grabbing the spiral properly. Eventually, the spiral could be retrieved laryngoscopically with arthroscopic grasping forceps. This incident caused laryngeal swelling and bleeding lacerations of the upper esophagus, which were clipped on a subsequent gastroscopy. No further long-lasting complications occurred in the patient.<\/jats:p><jats:p>\n            Conclusion Detachment of the spiral from the enteroscope is a potentially life-threatening and challenging complication of MSE. Artificial ventilation under observation by an anesthesiologist allowed for calm management of this dangerous situation and increased the overall safety of the procedure. Hence, we believe that in the context of antegrade MSE, general anesthesia with endotracheal intubation should be mandatory.<\/jats:p>","DOI":"10.1055\/a-2053-9238","type":"journal-article","created":{"date-parts":[[2023,4,12]],"date-time":"2023-04-12T22:53:55Z","timestamp":1681340035000},"page":"407-411","source":"Crossref","is-referenced-by-count":3,"title":["Spontaneous detachment of the spiral overtube from the endoscope in the upper esophagus: a case report and literature review of a rare complication during motorized spiral enteroscopy"],"prefix":"10.1055","volume":"62","author":[{"given":"Damian","family":"Wiedbrauck","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Allgemeines Krankenhaus Celle, Celle, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Felix","family":"Wiedbrauck","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Allgemeines Krankenhaus Celle, Celle, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ulrich","family":"Freund","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Allgemeines Krankenhaus Celle, Celle, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frauke","family":"Rodenberg","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Intensive Care Medicine, Allgemeines Krankenhaus Celle, Celle, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jens","family":"Prenzel","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Intensive Care Medicine, Allgemeines Krankenhaus Celle, Celle, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephan","family":"Hollerbach","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Allgemeines Krankenhaus Celle, Celle, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2023,4,12]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"1362","DOI":"10.1016\/j.gie.2020.10.028","article-title":"Total motorized spiral enteroscopy: first prospective clinical feasibility trial","volume":"93","author":"T Beyna","year":"2021","journal-title":"Gastrointest Endosc"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/j.vgie.2016.08.005","article-title":"Novel motorized spiral enteroscopy: first clinical case","volume":"1","author":"H Neuhaus","year":"2016","journal-title":"VideoGIE"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1055\/a-1964-2100","article-title":"Motorized spiral enteroscopy-assisted ERCP in surgically altered anatomy: early experience from a retrospective cohort study","author":"M Schneider","year":"2023","journal-title":"Endoscopy"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1055\/a-1949-8148","article-title":"[Erstbeschreibung einer kompletten Enteroskopie von der Ileoz\u00f6kalklappe bis zum Pylorus durch eine retrograde motorisierte Spiralenteroskopie]","author":"I Steinbr\u00fcck","year":"2022","journal-title":"Z Gastroenterol"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"1156","DOI":"10.1055\/a-1881-4691","article-title":"Safety of motorized spiral enteroscopy: is what we know today enough?","volume":"54","author":"M Pennazio","year":"2022","journal-title":"Endoscopy"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1055\/a-1866-3917","article-title":"The return of the helix: an evaluation of motorized spiral enteroscopy in actual daily clinical practice; a few points to \u201ctorque\u201d about and ponder upon\u2026: Referring to Al-Toma A et al","volume":"54","author":"E Despott","year":"2022","journal-title":"Endoscopy"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1136\/gutjnl-2019-319908","article-title":"Motorised spiral enteroscopy: first prospective clinical feasibility study","volume":"70","author":"T Beyna","year":"2021","journal-title":"Gut"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1016\/j.gie.2020.07.001","article-title":"Diagnostic yield and therapeutic impact of novel motorized spiral enteroscopy in small-bowel disorders: a single-center, real-world experience from a tertiary care hospital (with video)","volume":"93","author":"M Ramchandani","year":"2021","journal-title":"Gastrointest Endosc"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1055\/a-1783-4802","article-title":"The performance and safety of motorized spiral enteroscopy, including in patients with surgically altered gastrointestinal anatomy: a multicenter prospective study","author":"A Al-Toma","year":"2022","journal-title":"Endoscopy"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1016\/j.vgie.2020.08.001","article-title":"A spiraling journey into the small bowel: a case series of novel motorized power spiral enteroscopies","volume":"5","author":"M Prasad","year":"2020","journal-title":"VideoGIE"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1055\/a-1744-6738","article-title":"Ergebnisse der motorisierten Spiralenteroskopie des D\u00fcnndarms an 83 konsekutiven Patienten [Results of motorized spiral enteroscopy in 83 consecutive patients]","author":"H Buchholz","year":"2022","journal-title":"Z Gastroenterol"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"1147","DOI":"10.1055\/a-1831-6215","article-title":"Motorized spiral enteroscopy: results of an international multicenter prospective observational clinical study in patients with normal and altered gastrointestinal anatomy","volume":"54","author":"T Beyna","year":"2022","journal-title":"Endoscopy"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"e148","DOI":"10.1002\/deo2.148","article-title":"Safety and efficacy of the novel motorized power spiral enteroscopy: A single-center experience","volume":"3","author":"P Singh","year":"2023","journal-title":"DEN Open"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2022.10.017","article-title":"Diagnostic yield and technical performance of novel motorized spiral enteroscopy compared to single-balloon enteroscopy in suspected Crohn\u2019s disease: a prospective study (with videos)","author":"P Pal","year":"2022","journal-title":"Gastrointest Endosc"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1007\/s10620-022-07688-1","article-title":"Motorized Spiral Enteroscopy Is Effective in Patients with Prior Abdominal Surgery","author":"A Giordano","year":"2022","journal-title":"Dig Dis Sci"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1016\/j.gie.2022.09.030","article-title":"Motorized spiral enteroscopy versus double-balloon enteroscopy: a case-matched study","volume":"97","author":"W Chan","year":"2023","journal-title":"Gastrointest Endosc"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"212","DOI":"10.14735\/amgh2020212","article-title":"Motorized spiral enteroscopy \u2013 Our first experience","volume":"74","author":"P Falt","year":"2020","journal-title":"Gastroenterologie a Hepatologie"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.11622\/smedj.2022096","article-title":"Motorised spiral enteroscopy: pilot experience from a tertiary care centre in Singapore","author":"R Liang","year":"2022","journal-title":"Singapore Med J"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1055\/a-1532-1639","article-title":"Motorized spiral enteroscopy \u2013 when things happen: troubleshooting spiral disconnection at 90 minutes into the enteroscopic procedure","author":"E Steiner","year":"2021","journal-title":"Endoscopy"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"S69","DOI":"10.1055\/s-0042-1744719","article-title":"Disconnection of spiral overtube: an infrequent complication of motorized spiral enteroscopy","volume":"54","author":"R Mu\u00f1oz P\u00e9rez","year":"2022","journal-title":"Endoscopy"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"E31","DOI":"10.1055\/a-1930-5846","article-title":"Detachment of an enteroscope spiral fragment during anterograde motorized spiral enteroscopy","volume":"55","author":"L Barthet","year":"2023","journal-title":"Endoscopy"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"e00808","DOI":"10.14309\/crj.0000000000000808","article-title":"Spontaneous Migration of Spiral Fin Overtube During Motorized Spiral Enteroscopy","volume":"9","author":"S Rajput","year":"2022","journal-title":"ACG Case Rep J"}],"container-title":["Zeitschrift f\u00fcr Gastroenterologie"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2053-9238.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T14:18:34Z","timestamp":1730816314000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2053-9238"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,12]]},"references-count":22,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2024,3,5]]},"published-print":{"date-parts":[[2024,3]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2053-9238","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0044-2771","1439-7803"],"issn-type":[{"type":"print","value":"0044-2771"},{"type":"electronic","value":"1439-7803"}],"subject":[],"published":{"date-parts":[[2023,4,12]]}}}