{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T04:18:50Z","timestamp":1786594730500,"version":"build-2736575974"},"reference-count":33,"publisher":"Georg Thieme Verlag KG","issue":"13","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Knee Surg"],"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The aim of this study was to investigate the biomechanical effects of stem extension with a medial tibial bone defect in primary total knee arthroplasty (TKA) on load distribution and stress in the proximal tibia using finite element (FE) analysis.<\/jats:p><jats:p>FE simulations were performed on the tibia bone to evaluate the stress and strain on the tibia bone and bone cement. This was done to investigate the stress shielding effect, stability of the tibia plate, and the biomechanical effects in TKA models with various medial defects and different stem length models.<\/jats:p><jats:p>The results demonstrated that in the bone defect model, the longer the stem, the lower the average von Mises stress on the cortical and trabecular bones. In particular, as the bone defect increased, the average von Mises stress on cortical and trabecular bones increased. The average increase in stress according to the size of the bone defect was smaller in the long stem than in the short stem. The maximal principal strain on the trabecular bone occurred mainly at the contact point on the distal end of the stem of the tibial implant. When a short stem was applied, the maximal principal strain on the trabecular bone was approximately 8% and 20% smaller than when a long stem was applied or when no stem was applied, respectively.<\/jats:p><jats:p>The findings suggest that a short stem extension of the tibial component could help achieve excellent biomechanical results when performing TKA with a medial tibial bone defect.<\/jats:p>","DOI":"10.1055\/a-2344-5084","type":"journal-article","created":{"date-parts":[[2024,6,13]],"date-time":"2024-06-13T22:56:04Z","timestamp":1718319364000},"page":"879-886","source":"Crossref","is-referenced-by-count":7,"title":["Biomechanical Effects of Stem Extension of Tibial Components for Medial Tibial Bone Defects in Total Knee Arthroplasty: A Finite Element Study"],"prefix":"10.1055","volume":"37","author":[{"given":"Kwan Kyu","family":"Park","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1036-193X","authenticated-orcid":false,"given":"Kyoung-Tak","family":"Kang","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyuck Min","family":"Kwon","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyoung-Taek","family":"Hong","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Inuk","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byung Woo","family":"Cho","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong-Gon","family":"Koh","sequence":"additional","affiliation":[{"name":"Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2024,6,28]]},"reference":[{"issue":"22","key":"ref1","doi-asserted-by":"crossref","first-page":"2072","DOI":"10.2106\/JBJS.J.01143","article-title":"Increased long-term survival of posterior cruciate-retaining versus posterior cruciate-stabilizing total knee replacements","volume":"93","author":"M P Abdel","year":"2011","journal-title":"J Bone Joint Surg Am"},{"issue":"03","key":"ref2","doi-asserted-by":"crossref","first-page":"352","DOI":"10.4055\/cios20168","article-title":"The influence of femoral internal rotation on patellar tracking in total knee arthroplasty using gap technique","volume":"13","author":"D O Ko","year":"2021","journal-title":"Clin Orthop Surg"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"S190","DOI":"10.1016\/j.arth.2020.02.028","article-title":"Aseptic loosening at the tibia in total knee arthroplasty: a function of cement mantle quality?","volume":"35","author":"C B Hampton","year":"2020","journal-title":"J Arthroplasty"},{"issue":"04","key":"ref4","doi-asserted-by":"crossref","first-page":"1270","DOI":"10.1007\/s00167-018-5309-4","article-title":"Underhang of the tibial component increases tibial bone resorption after total knee arthroplasty","volume":"27","author":"S Gu","year":"2019","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"07","key":"ref5","doi-asserted-by":"crossref","first-page":"2319","DOI":"10.1016\/j.arth.2021.01.049","article-title":"A prophylactic tibial stem reduces rates of early aseptic loosening in patients with severe preoperative varus deformity in primary total knee arthroplasty","volume":"36","author":"V Hegde","year":"2021","journal-title":"J Arthroplasty"},{"issue":"02","key":"ref6","doi-asserted-by":"crossref","first-page":"126","DOI":"10.2106\/JBJS.K.00607","article-title":"Preoperative malalignment increases risk of failure after total knee arthroplasty","volume":"95","author":"M A Ritter","year":"2013","journal-title":"J Bone Joint Surg Am"},{"issue":"06","key":"ref7","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1302\/0301-620X.97B6.35185","article-title":"Dealing with the predicted increase in demand for revision total knee arthroplasty: challenges, risks and opportunities","volume":"97-B","author":"D F Hamilton","year":"2015","journal-title":"Bone Joint J"},{"issue":"05","key":"ref8","doi-asserted-by":"crossref","first-page":"1625","DOI":"10.1016\/j.arth.2016.12.001","article-title":"Catastrophic varus collapse of the tibia in obese total knee arthroplasty","volume":"32","author":"T K Fehring","year":"2017","journal-title":"J Arthroplasty"},{"issue":"08","key":"ref9","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1302\/0301-620X.94B8.28289","article-title":"The role of the design of tibial components and stems in knee replacement","volume":"94","author":"C E Scott","year":"2012","journal-title":"J Bone Joint Surg Br"},{"issue":"11","key":"ref10","doi-asserted-by":"crossref","first-page":"2534","DOI":"10.1097\/CORR.0000000000001912","article-title":"Do metaphyseal cones and stems provide any biomechanical advantage for moderate contained tibial defects in revision TKA? A finite-element analysis based on a cadaver model","volume":"479","author":"F J Quevedo Gonz\u00e1lez","year":"2021","journal-title":"Clin Orthop Relat Res"},{"issue":"01","key":"ref11","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1055\/s-0031-1275388","article-title":"Magnitude of cement-device interfacial stresses with and without tibial stemming: impact of BMI","volume":"24","author":"A Gopalakrishnan","year":"2011","journal-title":"J Knee Surg"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1097\/01.blo.0000187340.10003.68","article-title":"Cancellous bone strains indicate efficacy of stem augmentation in constrained condylar knees","volume":"440","author":"J J Rawlinson","year":"2005","journal-title":"Clin Orthop Relat Res"},{"issue":"01","key":"ref13","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1007\/s11999-016-4791-6","article-title":"Do stemmed tibial components in total knee arthroplasty improve outcomes in patients with obesity?","volume":"475","author":"S Parratte","year":"2017","journal-title":"Clin Orthop Relat Res"},{"issue":"11","key":"ref14","doi-asserted-by":"crossref","first-page":"3644","DOI":"10.1007\/s00167-016-4271-2","article-title":"Tibial component with and without stem extension in a trabecular metal cone construct","volume":"25","author":"M F Meijer","year":"2017","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"03","key":"ref15","doi-asserted-by":"crossref","first-page":"227","DOI":"10.5792\/ksrr.18.022","article-title":"Prophylactic tibial stem fixation in the obese: comparative early results in primary total knee arthroplasty","volume":"30","author":"J T Steere","year":"2018","journal-title":"Knee Surg Relat Res"},{"issue":"04","key":"ref16","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1302\/2046-3758.94.BJR-2019-0239.R1","article-title":"Metaphyseal cones in revision total knee arthroplasty: the role of stems","volume":"9","author":"S Xie","year":"2020","journal-title":"Bone Joint Res"},{"issue":"367","key":"ref17","first-page":"216","article-title":"Pain at the end of the stem after revision total knee arthroplasty","author":"R L Barrack","year":"1999","journal-title":"Clin Orthop Relat Res"},{"issue":"02","key":"ref18","doi-asserted-by":"crossref","first-page":"e0246866","DOI":"10.1371\/journal.pone.0246866","article-title":"A three-dimensional finite element analysis on the effects of implant materials and designs on periprosthetic tibial bone resorption","volume":"16","author":"H J Park","year":"2021","journal-title":"PLoS ONE"},{"issue":"12","key":"ref19","doi-asserted-by":"crossref","first-page":"1481","DOI":"10.1016\/j.medengphy.2016.09.018","article-title":"Stress shielding in periprosthetic bone following a total knee replacement: effects of implant material, design and alignment","volume":"38","author":"Q-H Zhang","year":"2016","journal-title":"Med Eng Phys"},{"issue":"06","key":"ref20","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1016\/j.jbiomech.2006.05.020","article-title":"Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements","volume":"40","author":"A G Au","year":"2007","journal-title":"J Biomech"},{"issue":"03","key":"ref21","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1016\/j.knee.2020.02.019","article-title":"A finite element analysis of tibial tritanium cones without stems in varying bone defects","volume":"27","author":"S Xie","year":"2020","journal-title":"Knee"},{"issue":"05","key":"ref22","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1302\/2046-3758.115.BJR-2021-0537.R1","article-title":"Biomechanical effect of anatomical tibial component design on load distribution of medial proximal tibial bone in total knee arthroplasty : finite element analysis indicating anatomical design prevents stress-shielding","volume":"11","author":"B W Cho","year":"2022","journal-title":"Bone Joint Res"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"9641417","DOI":"10.1155\/2018\/9641417","article-title":"Biomechanical characteristics of three baseplate rotational arrangement techniques in total knee arthroplasty","volume":"2018","author":"K Kang","year":"2018","journal-title":"BioMed Res Int"},{"issue":"02","key":"ref24","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1002\/jor.23279","article-title":"Importance of joint line preservation in unicompartmental knee arthroplasty: finite element analysis","volume":"35","author":"O R Kwon","year":"2017","journal-title":"J Orthop Res"},{"issue":"01","key":"ref25","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1142\/S0219519410003666","article-title":"The influence of tibial prosthesis design features on stresses related to aseptic loosening and stress shielding","volume":"11","author":"D Y Chong","year":"2011","journal-title":"J Mech Med Biol"},{"issue":"08","key":"ref26","doi-asserted-by":"crossref","first-page":"2512","DOI":"10.1016\/j.arth.2018.03.058","article-title":"Using a tibial short extension stem reduces tibial component loosening after primary total knee arthroplasty in severely varus knees: long-term survival analysis with propensity score matching","volume":"33","author":"M H Park","year":"2018","journal-title":"J Arthroplasty"},{"issue":"10","key":"ref27","doi-asserted-by":"crossref","first-page":"3031","DOI":"10.1016\/j.arth.2020.05.068","article-title":"Metaphyseal stem extension improves tibial stability in cementless total knee arthroplasty","volume":"35","author":"M P Morwood","year":"2020","journal-title":"J Arthroplasty"},{"issue":"02","key":"ref28","doi-asserted-by":"crossref","first-page":"168","DOI":"10.4055\/cios20079","article-title":"Treatment of 10-mm-deep or greater uncontained tibial bone defects in primary total knee reconstruction without metal augmentation: autologous oblique structural peg bone and cancellous chip bone grafting","volume":"13","author":"J G Chon","year":"2021","journal-title":"Clin Orthop Surg"},{"key":"ref29","doi-asserted-by":"crossref","first-page":"104006","DOI":"10.1016\/j.compbiomed.2020.104006","article-title":"Biomechanical comparison between metal block and cement-screw techniques for the treatment of tibial bone defects in total knee arthroplasty based on finite element analysis","volume":"125","author":"Y Liu","year":"2020","journal-title":"Comput Biol Med"},{"key":"ref30","doi-asserted-by":"crossref","first-page":"109941","DOI":"10.1016\/j.msec.2019.109941","article-title":"A review of materials for managing bone loss in revision total knee arthroplasty","volume":"104","author":"R Shafaghi","year":"2019","journal-title":"Mater Sci Eng C"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.arth.2004.03.002","article-title":"Bone loss in total knee arthroplasty: graft augment and options","volume":"19","author":"J M Cuckler","year":"2004","journal-title":"J Arthroplasty"},{"issue":"03","key":"ref32","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1016\/j.jbiomech.2007.10.006","article-title":"Strain shielding in proximal tibia of stemmed knee prosthesis: experimental study","volume":"41","author":"A Completo","year":"2008","journal-title":"J Biomech"},{"issue":"05","key":"ref33","doi-asserted-by":"crossref","first-page":"634","DOI":"10.3390\/medicina58050634","article-title":"Tibial stem extension versus standard configuration in total knee arthroplasty: a biomechanical assessment according to bone properties","volume":"58","author":"A C Filip","year":"2022","journal-title":"Medicina (Kaunas)"}],"container-title":["The Journal of Knee Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2344-5084.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T13:40:10Z","timestamp":1730814010000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2344-5084"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,13]]},"references-count":33,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2024,10,8]]},"published-print":{"date-parts":[[2024,11]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2344-5084","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["1538-8506","1938-2480"],"issn-type":[{"value":"1538-8506","type":"print"},{"value":"1938-2480","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,6,13]]},"published":{"date-parts":[[2024,6,13]]}}}