{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T04:31:18Z","timestamp":1777437078390,"version":"3.51.4"},"reference-count":10,"publisher":"Georg Thieme Verlag KG","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Facial Plast Surg"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Generally, revision rhinoplasty cases require the use of stiff grafts to restore the lost support. However, the majority of patients indicated for revision surgery present with a lack of a bony cartilaginous framework of the septum, especially after previous septoplasty. Thus, surgeons are compelled to harvest costal cartilage. At the same time, rib graft harvesting is associated with additional trauma and a risk of serious complications. Being ENT surgeons, we often resect a part of the lateral wall of the inferior nasal meatus during the extended endoscopic approach to the maxillary sinus. We supposed that this bone plate could be used as a donor site for rhinoplasty graft harvesting. The aim of our study was a radiological assessment of the feasibility and limits of using the inferior meatus lateral wall (IMLW) as a donor site for rhinoplasty bone graft.<\/jats:p><jats:p>A retrospective evaluation of 100 CT scans of sinuses was conducted. Further measurements of the IMLW were performed: average length and width (28.06\u2009\u00b1\u20094.03\u2009mm and 19.73\u2009\u00b1\u20093.08\u2009mm, respectively), thickness (0.62\u2009\u00b1\u20090.21\u2009mm), and average deviation from the sagittal plane (17.7\u2009\u00b1\u20099.53\u2009degrees). According to the obtained measurements, the described donor site is appropriate for harvesting nice straight bony fragments.<\/jats:p><jats:p>The IMLW bone graft was used in four revision rhinoplasty cases. There were no postoperative complications. During the long-term follow-up, patients reported significant improvement in aesthetics, function, and social aspects according to Rhinoplasty Outcome Evaluation. Thus, the described technique is an easy and safe method for bone harvesting for revision rhinoplasty. Our first experience demonstrated the convenience and stability of IMLW grafts for revision rhinoplasty during the follow-up period of up to 2 years.<\/jats:p>","DOI":"10.1055\/a-2353-3380","type":"journal-article","created":{"date-parts":[[2024,6,26]],"date-time":"2024-06-26T19:20:04Z","timestamp":1719429604000},"page":"364-370","source":"Crossref","is-referenced-by-count":1,"title":["The Lateral Wall of the Inferior Meatus as a New Graft Source for Rhinoplasty: Radiological Study and Surgical Technique"],"prefix":"10.1055","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5574-8292","authenticated-orcid":false,"given":"Yury","family":"Rusetsky","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Central State Medical Academy, Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6537-0510","authenticated-orcid":false,"given":"Zhanna","family":"Mokoyan","sequence":"additional","affiliation":[{"name":"Department of Ear, Nose and Throat Diseases, Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University (Sechenov University) of the Russian Federation Ministry of Health, Sechenov University, Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7808-3980","authenticated-orcid":false,"given":"Margarita","family":"Dutova","sequence":"additional","affiliation":[{"name":"Department of Radiology, Federal State Budgetary Educational Institution of Higher Education \u201cA.I. Evdokimov Moscow State University of Medicine and Dentistry\u201d of the Ministry of Healthcare of The Russian Federation, Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-6435-7003","authenticated-orcid":false,"given":"Anar","family":"Sadigov","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology Central State Medical Academy, Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8786-3738","authenticated-orcid":false,"given":"Natalia","family":"Balybina","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology Central State Medical Academy, Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8696-1651","authenticated-orcid":false,"given":"Olga","family":"Chernova","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, \u201cSemeynaya\u201d Private Clinic, Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2024,7,19]]},"reference":[{"issue":"02","key":"ref1","doi-asserted-by":"crossref","first-page":"40e","DOI":"10.1097\/PRS.0b013e3181c82f12","article-title":"Current status of grafts and implants in rhinoplasty: part I. Autologous grafts","volume":"125","author":"A Sajjadian","year":"2010","journal-title":"Plast Reconstr Surg"},{"issue":"05","key":"ref2","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1097\/PRS.0000000000009057","article-title":"Current practices in dorsal augmentation rhinoplasty","volume":"149","author":"M Fisher","year":"2022","journal-title":"Plast Reconstr Surg"},{"issue":"01","key":"ref3","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1007\/s00266-022-03075-3","article-title":"Complications associated with autologous costal cartilage used in rhinoplasty: an updated meta-analysis","volume":"47","author":"H Chen","year":"2023","journal-title":"Aesthetic Plast Surg"},{"issue":"06","key":"ref4","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1055\/s-0033-1360592","article-title":"Bone recycling in nasal septal reconstruction","volume":"29","author":"F Apaydin","year":"2013","journal-title":"Facial Plast Surg"},{"issue":"11","key":"ref5","doi-asserted-by":"crossref","first-page":"4304","DOI":"10.1016\/j.bjps.2022.08.046","article-title":"The ethmoid bone is the ideal graft to strengthen nasal septum L-strut among different grafts: an evaluation based on finite element analysis","volume":"75","author":"Y An","year":"2022","journal-title":"J Plast Reconstr Aesthet Surg"},{"issue":"02","key":"ref6","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1177\/019459989010200210","article-title":"Surgical anatomy of the lateral nasal wall","volume":"102","author":"K H Calhoun","year":"1990","journal-title":"Otolaryngol Head Neck Surg"},{"issue":"04","key":"ref7","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1159\/000518279","article-title":"Endoscopic inferior meatal antrostomy for antrochoanal polyps: a long-term follow-up","volume":"84","author":"R Landsberg","year":"2022","journal-title":"ORL J Otorhinolaryngol Relat Spec"},{"issue":"03","key":"ref8","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1007\/s002660010031","article-title":"Outcomes research in facial plastic surgery: a review and new directions","volume":"24","author":"R Alsarraf","year":"2000","journal-title":"Aesthetic Plast Surg"},{"issue":"02","key":"ref9","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1097\/SCS.0000000000005149","article-title":"Anatomical characteristics of the perpendicular plate of the ethmoid: an analysis of paranasal sinus computed tomography via three-dimensional reconstruction","volume":"30","author":"X Yang","year":"2019","journal-title":"J Craniofac Surg"},{"issue":"05","key":"ref10","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1016\/j.otc.2006.07.003","article-title":"Anatomy of the orbit, lacrimal apparatus, and lateral nasal wall","volume":"39","author":"J B Chastain","year":"2006","journal-title":"Otolaryngol Clin North Am"}],"container-title":["Facial Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2353-3380.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,28]],"date-time":"2025-08-28T23:30:03Z","timestamp":1756423803000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2353-3380"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,26]]},"references-count":10,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2025,5,14]]},"published-print":{"date-parts":[[2025,6]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2353-3380","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0736-6825","1098-8793"],"issn-type":[{"value":"0736-6825","type":"print"},{"value":"1098-8793","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,6,26]]},"published":{"date-parts":[[2024,6,26]]}}}