{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T02:47:15Z","timestamp":1792118835895,"version":"4.4.0"},"reference-count":31,"publisher":"Georg Thieme Verlag KG","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Knee Surg"],"published-print":{"date-parts":[[2025,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Robotic-assisted devices help provide precise component positioning in conversion of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA). A few studies offer surgical techniques for computed tomography (CT) based robotic-assisted conversion of UKA to TKA; however, no studies to date detail this procedure utilizing a non-CT-based robotic-assisted device. This article introduces a novel technique employing a non-CT-based robotic-assisted device (ROSA Knee System, Zimmer Biomet, Warsaw, IN) for converting UKA to TKA with a focus on its efficacy in gap balancing. We present three patients (ages 46\u201366 years) who were evaluated for conversion of UKA to TKA for aseptic loosening, stress fracture, and progressive osteoarthritis. Each patient underwent robotic-assisted conversion to TKA. Postoperative assessments at 6 months revealed improved pain, function, and radiographic stability. Preoperative planning included biplanar long leg radiographs to determine the anatomic and mechanical axis of the leg. After arthrotomy with a standard medial parapatellar approach, infrared reflectors were pinned into the femur and tibia, followed by topographical mapping of the knee with the UKA in situ. The intraoperative software was utilized to evaluate flexion and extension balancing and plan bony resections. Then, the robotic arm guided placement of the femoral and tibial guide pins and the UKA components were removed. After bony resection of the distal femur and proximal tibia, the intraoperative software was used to reassess the extension gap, and plan posterior condylar resection to have the flexion gap match the extension gap. The use of a non-CT-based robotic-assisted device in conversion of UKA to TKA is a novel technique and a good option for surgeons familiar with robotic-assisted arthroplasty, resulting in excellent outcomes at 6 months.<\/jats:p>","DOI":"10.1055\/a-2421-5496","type":"journal-article","created":{"date-parts":[[2024,9,24]],"date-time":"2024-09-24T22:41:32Z","timestamp":1727217692000},"page":"141-147","source":"Crossref","is-referenced-by-count":3,"title":["The Conversion of Unicompartmental Knee Arthroplasty to Total Knee Arthroplasty with Non-CT-Based Robotic Assistance: A Novel Surgical Technique and Case Series"],"prefix":"10.1055","volume":"38","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-1189-348X","authenticated-orcid":false,"given":"Hamza M.","family":"Raja","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Henry Ford Hospital System, Detroit, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6137-5813","authenticated-orcid":false,"given":"Luke","family":"Wesemann","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Henry Ford Hospital System, Detroit, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael A.","family":"Charters","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Henry Ford Hospital System, Detroit, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W. Trevor","family":"North","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Henry Ford Hospital System, Detroit, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2024,11,6]]},"reference":[{"issue":"10","key":"ref1","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1055\/s-0038-1625961","article-title":"Unicompartmental knee arthroplasty: the past, current controversies, and future perspectives","volume":"31","author":"S Johal","year":"2018","journal-title":"J Knee Surg"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.arth.2012.03.022","article-title":"Total knee arthroplasty has higher postoperative morbidity than unicompartmental knee arthroplasty: a multicenter analysis","volume":"27","author":"N M Brown","year":"2012","journal-title":"J Arthroplasty"},{"issue":"10","key":"ref3","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1007\/s00167-008-0596-9","article-title":"Participation in sporting activities following knee replacement: total versus unicompartmental","volume":"16","author":"G P Hopper","year":"2008","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"06","key":"ref4","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1016\/j.knee.2015.11.012","article-title":"A cost comparison of unicompartmental and total knee arthroplasty","volume":"23","author":"S Shankar","year":"2016","journal-title":"Knee"},{"key":"ref5","volume-title":"10th Annual Report of the National Joint Registry for England, Wales and Northern Ireland","author":"National Joint Registry","year":"2012"},{"issue":"01","key":"ref6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2106\/JBJS.N.00487","article-title":"Effect of surgical caseload on revision rate following total and unicompartmental knee replacement","volume":"98","author":"A D Liddle","year":"2016","journal-title":"J Bone Joint Surg Am"},{"issue":"03","key":"ref7","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.knee.2010.05.003","article-title":"Unicompartmental knee replacement for patients with partial thickness cartilage loss in the affected compartment","volume":"18","author":"H Pandit","year":"2011","journal-title":"Knee"},{"issue":"01","key":"ref8","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1186\/s10195-020-00551-x","article-title":"Unicompartmental knee arthroplasty, an enigma, and the ten enigmas of medial UKA","volume":"21","author":"A Mittal","year":"2020","journal-title":"J Orthop Traumatol"},{"issue":"07","key":"ref9","doi-asserted-by":"crossref","first-page":"1994","DOI":"10.1016\/j.arth.2018.01.050","article-title":"Robotic-assisted unicompartmental knee arthroplasty: state-of-the art and review of the literature","volume":"33","author":"A B Christ","year":"2018","journal-title":"J Arthroplasty"},{"issue":"02","key":"ref10","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1007\/s00402-021-03827-x","article-title":"Revision indications for medial unicompartmental knee arthroplasty: a systematic review","volume":"142","author":"M L Tay","year":"2022","journal-title":"Arch Orthop Trauma Surg"},{"issue":"01","key":"ref11","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1055\/s-0037-1601414","article-title":"Unicompartmental knee arthroplasty: modes of failure and conversion to total knee arthroplasty","volume":"5","author":"M Vasso","year":"2017","journal-title":"Joints"},{"issue":"12","key":"ref12","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.3928\/0147-7447-20021201-12","article-title":"The effect of implant constraint on results of conversion of unicompartmental knee arthroplasty to total knee arthroplasty","volume":"25","author":"M Miller","year":"2002","journal-title":"Orthopedics"},{"issue":"01","key":"ref13","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1186\/s13018-018-0859-1","article-title":"A meta-analysis of unicompartmental knee arthroplasty revised to total knee arthroplasty versus primary total knee arthroplasty","volume":"13","author":"X Sun","year":"2018","journal-title":"J Orthop Surg Res"},{"issue":"11","key":"ref14","doi-asserted-by":"crossref","first-page":"3403","DOI":"10.1007\/s00167-018-4909-3","article-title":"Inferior outcome of revision of unicompartmental knee arthroplasty to total knee arthroplasty compared with primary total knee arthroplasty: systematic review and meta-analysis","volume":"26","author":"J K Lee","year":"2018","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"20","key":"ref15","doi-asserted-by":"crossref","first-page":"e426","DOI":"10.5435\/JAAOS-D-17-00107","article-title":"Management of the failed medial unicompartmental knee arthroplasty","volume":"26","author":"D A Crawford","year":"2018","journal-title":"J Am Acad Orthop Surg"},{"issue":"09","key":"ref16","doi-asserted-by":"crossref","first-page":"e20.00198","DOI":"10.2106\/JBJS.RVW.20.00198","article-title":"Conversion total knee arthroplasty","volume":"9","author":"P Ramamurti","year":"2021","journal-title":"JBJS Rev"},{"issue":"08","key":"ref17","doi-asserted-by":"crossref","first-page":"627","DOI":"10.2106\/JBJS.15.00664","article-title":"Improved accuracy of component positioning with robotic-assisted unicompartmental knee arthroplasty: data from a prospective, randomized controlled study","volume":"98","author":"S W Bell","year":"2016","journal-title":"J Bone Joint Surg Am"},{"issue":"03","key":"ref18","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1055\/s-0038-1641729","article-title":"Robotic-arm assisted total knee arthroplasty demonstrated greater accuracy and precision to plan compared with manual techniques","volume":"32","author":"E L Hampp","year":"2019","journal-title":"J Knee Surg"},{"issue":"12","key":"ref19","doi-asserted-by":"crossref","first-page":"2373","DOI":"10.1016\/j.arth.2013.12.010","article-title":"Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis. A prospective randomised study","volume":"29","author":"M HL Liow","year":"2014","journal-title":"J Arthroplasty"},{"issue":"02","key":"ref20","doi-asserted-by":"crossref","first-page":"169","DOI":"10.4055\/cios.2017.9.2.169","article-title":"Robotic total knee arthroplasty with a cruciate-retaining implant: a 10-year follow-up study","volume":"9","author":"H Y Yang","year":"2017","journal-title":"Clin Orthop Surg"},{"issue":"01","key":"ref21","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1007\/s11999-012-2407-3","article-title":"Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA","volume":"471","author":"E-K Song","year":"2013","journal-title":"Clin Orthop Relat Res"},{"issue":"12","key":"ref22","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1080\/17434440.2017.1392237","article-title":"Utilization of robotic-arm assisted total knee arthroplasty for soft tissue protection","volume":"14","author":"A A Sultan","year":"2017","journal-title":"Expert Rev Med Devices"},{"issue":"04","key":"ref23","first-page":"278","article-title":"Robotic-arm assisted total knee arthroplasty: the relationship between bone resection, gap balancing and resultant implant alignment","volume":"11","author":"N D Clement","year":"2023","journal-title":"Arch Bone Jt Surg"},{"issue":"01","key":"ref24","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1186\/s43019-020-00056-1","article-title":"Management of failed UKA to TKA: conventional versus robotic-assisted conversion technique","volume":"32","author":"A G Yun","year":"2020","journal-title":"Knee Surg Relat Res"},{"issue":"08","key":"ref25","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1302\/2058-5241.3.170060","article-title":"Update on unicompartmental knee arthroplasty: current indications and failure modes","volume":"3","author":"M Vasso","year":"2018","journal-title":"EFORT Open Rev"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"S105","DOI":"10.1016\/j.arth.2018.03.023","article-title":"Revision of unicompartmental knee arthroplasty to total knee arthroplasty: is it as good as a primary result?","volume":"33","author":"A V Lombardi Jr","year":"2018","journal-title":"J Arthroplasty"},{"issue":"01","key":"ref27","doi-asserted-by":"crossref","first-page":"46","DOI":"10.5792\/ksrr.2016.28.1.46","article-title":"Analysis and treatment of complications after unicompartmental knee arthroplasty","volume":"28","author":"K T Kim","year":"2016","journal-title":"Knee Surg Relat Res"},{"issue":"10","key":"ref28","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1302\/2058-5241.4.190022","article-title":"Robotic technology in total knee arthroplasty: a systematic review","volume":"4","author":"B Kayani","year":"2019","journal-title":"EFORT Open Rev"},{"issue":"01","key":"ref29","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1055\/s-0037-1608840","article-title":"Coronal correction for severe deformity using robotic-assisted total knee arthroplasty","volume":"31","author":"R C Marchand","year":"2018","journal-title":"J Knee Surg"},{"issue":"04","key":"ref30","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/j.knee.2014.04.012","article-title":"5-Year cost\/benefit analysis of revision of failed unicompartmental knee replacements (UKRs); not \u201cjust\u201d a primary total knee replacement (TKR)","volume":"21","author":"S C Jonas","year":"2014","journal-title":"Knee"},{"key":"ref31","first-page":"4806987","article-title":"Expanding robotic arm-assisted knee surgery: the first attempt to use the system for knee revision arthroplasty","volume":"2020","author":"D Kalavrytinos","year":"2020","journal-title":"Case Rep Orthop"}],"container-title":["The Journal of Knee Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2421-5496.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,6]],"date-time":"2025-02-06T00:07:49Z","timestamp":1738800469000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2421-5496"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,24]]},"references-count":31,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2025,2,5]]},"published-print":{"date-parts":[[2025,2]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2421-5496","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["1538-8506","1938-2480"],"issn-type":[{"value":"1538-8506","type":"print"},{"value":"1938-2480","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,9,24]]},"published":{"date-parts":[[2024,9,24]]}}}