{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T10:28:18Z","timestamp":1776940098245,"version":"3.51.4"},"reference-count":13,"publisher":"Georg Thieme Verlag KG","issue":"04","funder":[{"name":"ambu GmbH"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Endoscopy"],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The trend toward disposable products in gastrointestinal endoscopy, including single-use endoscopes, remains undeterred, even though crucial questions of sustainability and performance have not been sufficiently studied. The first single-use therapeutic gastroscope was recently approved in Europe, but clinical data to support its use are currently lacking. We aimed to evaluate the performance of this novel device in routine procedures requiring a large working channel.<\/jats:p><jats:p>Between January and May 2024, consecutive patients with an indication for therapeutic gastroscopy were included prospectively. The primary outcome was intraprocedural technical success rate.<\/jats:p><jats:p>Eight gastrointestinal bleedings, two pancreatic necrosectomies, four foreign body removals, four stent placements, and two cryo-balloon ablations were performed. The technical success rate was 84% (16\/19 patients). Crossover to a standard endoscope was required in three procedures. Clinical success was achieved in all cases with technical success. Overall user experience was 3.2 on a Likert scale of 1\u20135. No adverse events were reported.<\/jats:p><jats:p>The single-use therapeutic gastroscope demonstrated feasibility in various therapeutic procedures; however, a 16% crossover rate and fair user assessment score suggest that further technical improvements to the device are necessary.<\/jats:p>","DOI":"10.1055\/a-2436-7933","type":"journal-article","created":{"date-parts":[[2024,10,8]],"date-time":"2024-10-08T23:51:38Z","timestamp":1728431498000},"page":"339-344","source":"Crossref","is-referenced-by-count":4,"title":["Clinical evaluation of a novel single-use therapeutic gastroscope: a pilot feasibility study"],"prefix":"10.1055","volume":"57","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8745-8510","authenticated-orcid":false,"given":"Christoph","family":"R\u00f6mmele","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mousa","family":"Ayoub","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julia","family":"Wanzl","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vidan","family":"Tadic","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Georg","family":"Braun","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tobias","family":"Weber","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2255-7032","authenticated-orcid":false,"given":"Markus Wolfgang","family":"Scheppach","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Roser","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katharina","family":"Matic","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandra","family":"Nagl","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helmut","family":"Messmann","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alanna","family":"Ebigbo","sequence":"additional","affiliation":[{"name":"Gastroenterology, Faculty of Medicine, University Hospital Augsburg, Augsburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2024,11,27]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"1718","DOI":"10.1007\/s10620-022-07441-8","article-title":"Gastrointestinal endoscopy-associated infections: update on an emerging issue","volume":"67","author":"A Deb","year":"2022","journal-title":"Dig Dis Sci"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1016\/j.dld.2023.07.026","article-title":"International Delphi consensus study on disposable single-use endoscopy: a path to clinical adoption","volume":"56","author":"A Repici","year":"2024","journal-title":"Dig Liver Dis"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.vgie.2023.11.006","article-title":"Role of single-use gastroscopes in advanced endoscopy","volume":"9","author":"F Baldaque-Silva","year":"2024","journal-title":"VideoGIE"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"E428","DOI":"10.1055\/a-2271-2303","article-title":"Performance of a single-use gastroscope for esophagogastroduodenoscopy: prospective evaluation","volume":"12","author":"K van der Ploeg","year":"2024","journal-title":"Endosc Int Open"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1055\/a-2089-5969","article-title":"Evaluation of a single-use gastroscope in patients presenting with suspected upper gastrointestinal hemorrhage: a pilot feasibility study (One-Scope I)","volume":"55","author":"A Ebigbo","year":"2023","journal-title":"Endoscopy"},{"issue":"S 02","key":"ref6","first-page":"S183","article-title":"Comparison of single use versus reusable gastroscope environmental impacts for an upper GI endoscopy procedure","volume":"56","author":"M Pioche","year":"2024","journal-title":"Endoscopy"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1055\/s-0043-116856","article-title":"S2k Guideline Gastrointestinal Bleeding \u2013 Guideline of the German Society of Gastroenterology DGVS","volume":"55","author":"M Gotz","year":"2017","journal-title":"Z Gastroenterol"},{"issue":"S 02","key":"ref8","first-page":"S83","article-title":"Preliminary results from the OneScope-II study: a randomized controlled single-center trial comparing single-use and reusable gastroscopes in patients with clinical signs of upper gastrointestinal bleeding","volume":"56","author":"C R\u00f6mmele","year":"2024","journal-title":"Endoscopy"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1136\/gutjnl-2021-324729","article-title":"Estimating the environmental impact of disposable endoscopic equipment and endoscopes","volume":"71","author":"S Namburar","year":"2022","journal-title":"Gut"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1016\/j.gie.2022.06.014","article-title":"Environmental and health outcomes of single-use versus reusable duodenoscopes","volume":"96","author":"NNT Le","year":"2022","journal-title":"Gastrointest Endosc"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.gie.2022.03.024","article-title":"Disposable versus reusable gastroscopes: a prospective randomized noninferiority trial","volume":"96","author":"X Luo","year":"2022","journal-title":"Gastrointest Endosc"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1055\/a-1859-3726","article-title":"Reducing the environmental footprint of gastrointestinal endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) and European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA) Position Statement","volume":"54","author":"E Rodriguez de Santiago","year":"2022","journal-title":"Endoscopy"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1136\/gutjnl-2022-328460","article-title":"Green endoscopy: British Society of Gastroenterology (BSG), Joint Accreditation Group (JAG) and Centre for Sustainable Health (CSH) joint consensus on practical measures for environmental sustainability in endoscopy","volume":"72","author":"S Sebastian","year":"2023","journal-title":"Gut"}],"container-title":["Endoscopy"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2436-7933.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T02:16:37Z","timestamp":1742955397000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2436-7933"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,8]]},"references-count":13,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2025,3,25]]},"published-print":{"date-parts":[[2025,4]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2436-7933","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0013-726X","1438-8812"],"issn-type":[{"value":"0013-726X","type":"print"},{"value":"1438-8812","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,10,8]]},"published":{"date-parts":[[2024,10,8]]}}}