{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T18:09:11Z","timestamp":1788977351953,"version":"build-2803163510"},"reference-count":19,"publisher":"Georg Thieme Verlag KG","issue":"03","funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"crossref","award":["SCHR 1666\/2-1"],"award-info":[{"award-number":["SCHR 1666\/2-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Forschung f\u00fcr das Sehen, F\u00f6rderverein des Zentrums f\u00fcr Augenheilkunde, Universit\u00e4t zu K\u00f6ln, K\u00f6ln"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Klin Monbl Augenheilkd"],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n               Purpose The aim of this study was to investigate the acceptance of innovative perimetry methods such as virtual reality perimetry (VRP) and tablet-based perimetry (TBP) in comparison to conventional hemisphere perimetry (HP) in glaucoma patients for the first time in Germany.<\/jats:p><jats:p>\n               Patients and Methods We examined 204 glaucoma patients using the 30\u200a\u2013\u200a2\u2009TOP algorithm (Octopus, Haag-Streit) followed by one of the two new methods: Group 1 (VRP; n\u2009=\u2009101) and Group 2 (TBP using the Melbourne Rapid Fields Glaucoma App; n\u2009=\u2009103). Subsequently, patients were asked to fill out a questionnaire on their experience with the new examination compared to the conventional examination.<\/jats:p><jats:p>\n               Results More than three-quarters of patients at 77% in Group 1 (VR) and 89.9% of patients in Group 2 (TBP) found the respective new examination method \u201ceasier\u201d or \u201cmuch easier\u201d than the conventional HP. An overwhelming majority of patients in Group 1 and Group 2 found the new method more comfortable at 86% and 90.9%, respectively. Examination durations were: 2.67\u2009\u00b1\u20090.98\u2009min for HP, 6.26\u2009\u00b1\u20091.88\u2009min for VR perimetry, and 4\u2009\u00b1\u20090.71\u2009min for the tablet method; figures given as means \u00b1 standard deviation. Just over half the patients at 51% found HP and VR headset to be similar for duration with 54% preferring the tablet over conventional hemisphere perimetry. By far the most patients in Groups 1 and 2 at 80% and 81.8%, respectively, reported willingness to use the new perimetry method regularly in future follow-up examinations.<\/jats:p><jats:p>\n               Conclusion Most glaucoma patients surveyed consistently responded favourably to VR headset and tablet-based perimetry, preferring these examinations to conventional hemispherical perimetry.<\/jats:p>","DOI":"10.1055\/a-2511-4087","type":"journal-article","created":{"date-parts":[[2025,1,7]],"date-time":"2025-01-07T19:14:12Z","timestamp":1736277252000},"page":"219-227","source":"Crossref","is-referenced-by-count":2,"title":["Acceptance of Novel Perimetry Methods in Germany: Virtual Reality Perimetry and Tablet-based Perimetry in Glaucoma Patients"],"prefix":"10.1055","volume":"242","author":[{"given":"Silvia","family":"Schrittenlocher","sequence":"additional","affiliation":[{"name":"Zentrum f\u00fcr Augenheilkunde, Uniklinik K\u00f6ln, Deutschland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincent","family":"L\u00fcke","sequence":"additional","affiliation":[{"name":"Zentrum f\u00fcr Augenheilkunde, Uniklinik K\u00f6ln, Deutschland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hanne","family":"Irle","sequence":"additional","affiliation":[{"name":"Zentrum f\u00fcr Augenheilkunde, Uniklinik K\u00f6ln, Deutschland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jithmi","family":"Weliwitage","sequence":"additional","affiliation":[{"name":"Institut f\u00fcr Medizinische Statistik und Bioinformatik, Universit\u00e4t zu K\u00f6ln, Deutschland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan Niklas","family":"L\u00fcke","sequence":"additional","affiliation":[{"name":"Zentrum f\u00fcr Augenheilkunde, Uniklinik K\u00f6ln, Deutschland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Kong","sequence":"additional","affiliation":[{"name":"Ophthalmology, The Royal Victorian Eye and Ear Hospital, East Melbourne, Australia"},{"name":"Centre for Eye Research Australia, The Royal Victorian Eye and Ear Hospital, East Melbourne, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Algis J.","family":"Vingrys","sequence":"additional","affiliation":[{"name":"Centre for Eye Research Australia, The Royal Victorian Eye and Ear Hospital, East Melbourne, Australia"},{"name":"Department of Optometry and Vision Sciences, The University of Melbourne Faculty of Medicine Dentistry and Health Sciences, Melbourne, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandra","family":"Lappas","sequence":"additional","affiliation":[{"name":"Zentrum f\u00fcr Augenheilkunde, Uniklinik K\u00f6ln, Deutschland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claus","family":"Cursiefen","sequence":"additional","affiliation":[{"name":"Zentrum f\u00fcr Augenheilkunde, Uniklinik K\u00f6ln, Deutschland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas S.","family":"Dietlein","sequence":"additional","affiliation":[{"name":"Zentrum f\u00fcr Augenheilkunde, Uniklinik K\u00f6ln, Deutschland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2025,3,24]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"2127","DOI":"10.1016\/j.ophtha.2008.08.013","article-title":"Assessment of patient opinions of different clinical tests used in the management of glaucoma","volume":"115","author":"S K Gardiner","year":"2008","journal-title":"Ophthalmology"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"1128","DOI":"10.1136\/bjophthalmol-2015-307110","article-title":"Anxiety in visual field testing","volume":"100","author":"S S Chew","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"2883","DOI":"10.4103\/ijo.IJO_508_22","article-title":"Study of anxiety in patients with glaucoma undergoing standard automated perimetry and optical coherence tomography \u2013 A prospective comparative study","volume":"70","author":"S Kaliaperumal","year":"2022","journal-title":"Indian J Ophthalmol"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"S71","DOI":"10.1016\/j.ophtha.2017.04.009","article-title":"Will Perimetry Be Performed to Monitor Glaucoma in 2025?","volume":"124(12S)","author":"A S Camp","year":"2017","journal-title":"Ophthalmology"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1007\/s00417-002-0482-y","article-title":"Comparison of two fast strategies, SITA Fast and TOP, for the assessment of visual fields in glaucoma patients","volume":"240","author":"A J King","year":"2002","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1016\/s0002-9394(01)01424-6","article-title":"Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish interactive threshold algorithm-fast perimetry in a glaucoma practice","volume":"133","author":"A C Wadood","year":"2002","journal-title":"Am J Ophthalmol"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1097\/IJG.0000000000002022","article-title":"Home-Based Perimetry for Glaucoma: Where Are We Now?","volume":"31","author":"Q Daka","year":"2022","journal-title":"J Glaucoma"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"125","DOI":"10.5005\/jp-journals-10078-1312","article-title":"Screening for Glaucomatous Visual Field Defects in Rural Australia with an iPad","volume":"15","author":"M A Chia","year":"2021","journal-title":"J Curr Glaucoma Pract"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1167\/tvst.12.1.6","article-title":"Evaluation of Virtual Reality Perimetry and Standard Automated Perimetry in Normal Children","volume":"12","author":"S L Groth","year":"2023","journal-title":"Transl Vis Sci Technol"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1167\/tvst.10.12.10","article-title":"Virtual Reality-Based and Conventional Visual Field Examination Comparison in Healthy and Glaucoma Patients","volume":"10","author":"J Stapelfeldt","year":"2021","journal-title":"Transl Vis Sci Technol"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/j.ogla.2023.08.006","article-title":"Assessment of Remote Training, At-Home Testing, and Test-Retest Variability of a Novel Test for Clustered Virtual Reality Perimetry","volume":"7","author":"Z K Chia","year":"2024","journal-title":"Ophthalmol Glaucoma"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.ajo.2018.03.009","article-title":"Six-month Longitudinal Comparison of a Portable Tablet Perimeter With the Humphrey Field Analyzer","volume":"190","author":"S M Prea","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"4317","DOI":"10.3390\/jcm11154317","article-title":"Test Reliability and Compliance to a Twelve-Month Visual Field Telemedicine Study in Glaucoma Patients","volume":"11","author":"S M Prea","year":"2022","journal-title":"J Clin Med"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"33","DOI":"10.18502\/jovr.v17i1.10168","article-title":"Diagnostic Performance of the PalmScan VF2000 Virtual Reality Visual Field Analyzer for Identification and Classification of Glaucoma","volume":"17","author":"V Shetty","year":"2022","journal-title":"J Ophthalmic Vis Res"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1097\/OPX.0000000000001889","article-title":"Evaluation of the Melbourne Rapid Fields Test Procedure","volume":"99","author":"P A Harris","year":"2022","journal-title":"Optom Vis Sci"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1167\/tvst.5.6.2","article-title":"A Comparison of Perimetric Results from a Tablet Perimeter and Humphrey Field Analyzer in Glaucoma Patients","volume":"5","author":"Y X Kong","year":"2016","journal-title":"Transl Vis Sci Technol"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"8384509","DOI":"10.1155\/2020\/8384509","article-title":"Comparison of Perimetric Outcomes from Melbourne Rapid Fields Tablet Perimeter Software and Humphrey Field Analyzer in Glaucoma Patients","volume":"2020","author":"H Kumar","year":"2020","journal-title":"J Ophthalmol"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.ogla.2021.09.002","article-title":"Glaucoma Screening Using an iPad-Based Visual Field Test in a West African Population","volume":"5","author":"J Prince","year":"2022","journal-title":"Ophthalmol Glaucoma"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1097\/IJG.0000000000002296","article-title":"Participant Experience Using Novel Perimetry Tests to Monitor Glaucoma Progression","volume":"32","author":"S E Freeman","year":"2023","journal-title":"J Glaucoma"}],"container-title":["Klinische Monatsbl\u00e4tter f\u00fcr Augenheilkunde"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2511-4087.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T23:41:50Z","timestamp":1759362110000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2511-4087"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,7]]},"references-count":19,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2025,3,24]]},"published-print":{"date-parts":[[2025,3]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2511-4087","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0023-2165","1439-3999"],"issn-type":[{"value":"0023-2165","type":"print"},{"value":"1439-3999","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2025,1,7]]},"published":{"date-parts":[[2025,1,7]]}}}