{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,29]],"date-time":"2026-01-29T10:39:28Z","timestamp":1769683168650,"version":"3.49.0"},"reference-count":14,"publisher":"Georg Thieme Verlag KG","issue":"02","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rofo"],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Repeated whole-spine imaging in children and adolescents with scoliosis causes significant cumulative radiation exposure. Low-dose slot-scanning imaging can reduce radiation exposure. The aim of this study was to compare whole-spine imaging using the slot-scanning technique (SST) with conventional stitched radiography (SR) with regard to image quality and radiation dose.<\/jats:p>\n                  <jats:p>We recruited 30 patients with a clinical indication for whole-spine imaging by SST, who had prior whole-spine imaging by SR available. 41 images acquired using both techniques were analyzed. The dose area product (DAP) and patient age, weight, height, and body-mass index were recorded. Image quality was assessed for 28 anatomical landmarks on a 4-point Likert scale by 4 raters. Group-wise comparisons were performed using paired t-tests. Interrater rating reliability was assessed using the interrater correlation coefficient.<\/jats:p>\n                  <jats:p>The mean DAP was significantly lower for SST than for SR (SST 8.0 \u00b1 5.7 cGy \u00b7 cm\u00b2, SR 32.5 \u00b1 34.5 cGy \u00b7 cm\u00b2, p &lt; 0.001). The image quality was rated good for both modalities (means: SST 2.8 \u00b1 0.6, SR 2.7 \u00b1 0.5, p = 0.38). There was no significant difference in image quality ratings between both modalities. The inter-rater reliability was excellent with an inter-rater correlation coefficient of 0.86. Orthopedic surgeons rated the image quality of SST significantly better than that of SR.<\/jats:p>\n                  <jats:p>This study shows a significant reduction in radiation exposure for slot-scanning whole-spine imaging compared to stitched radiography with equal image quality, which facilitates the reduction of radiation exposure for repeated whole-spine imaging in children and adolescents to 25%.<\/jats:p>","DOI":"10.1055\/a-2564-0580","type":"journal-article","created":{"date-parts":[[2025,4,25]],"date-time":"2025-04-25T19:14:43Z","timestamp":1745608483000},"page":"219-227","source":"Crossref","is-referenced-by-count":0,"title":["Equal image quality and reduced radiation exposure in whole-spine X-ray imaging with slot-scanning technique compared with stitched radiography"],"prefix":"10.1055","volume":"198","author":[{"given":"Hendrik","family":"Liebscher","sequence":"additional","affiliation":[{"name":"Institute and Polyclinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus at the Technische Universit\u00e4t Dresden, Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mechthild","family":"Scherzer","sequence":"additional","affiliation":[{"name":"Institute and Polyclinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus at the Technische Universit\u00e4t Dresden, Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph","family":"Mei\u00dfner","sequence":"additional","affiliation":[{"name":"Institute and Polyclinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus at the Technische Universit\u00e4t Dresden, Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Zwingenberger","sequence":"additional","affiliation":[{"name":"University Centre for Orthopaedics, Traumatology and Plastic Surgery, University Hospital Carl Gustav Carus at the Technische Universit\u00e4t Dresden, Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Uwe","family":"Platz","sequence":"additional","affiliation":[{"name":"University Centre for Orthopaedics, Traumatology and Plastic Surgery, University Hospital Carl Gustav Carus at the Technische Universit\u00e4t Dresden, Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patricia","family":"Hahlbohm","sequence":"additional","affiliation":[{"name":"Institute and Polyclinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus at the Technische Universit\u00e4t Dresden, Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Felix","family":"Sch\u00f6n","sequence":"additional","affiliation":[{"name":"Institute and Polyclinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus at the Technische Universit\u00e4t Dresden, Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jens-Peter","family":"K\u00fchn","sequence":"additional","affiliation":[{"name":"Institute and Polyclinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus at the Technische Universit\u00e4t Dresden, Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ralf-Thorsten","family":"Hoffmann","sequence":"additional","affiliation":[{"name":"Institute and Polyclinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus at the Technische Universit\u00e4t Dresden, Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7096-5199","authenticated-orcid":false,"given":"Sophia Freya Ulrike","family":"Blum","sequence":"additional","affiliation":[{"name":"Institute and Polyclinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus at the Technische Universit\u00e4t Dresden, Dresden, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2025,4,25]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"1527","DOI":"10.1016\/S0140-6736(08)60658-3","article-title":"Adolescent idiopathic scoliosis","volume":"371","author":"SL Weinstein","year":"2008","journal-title":"The Lancet"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"2052","DOI":"10.1097\/00007632-200008150-00009","article-title":"Breast Cancer Mortality After Diagnostic Radiography: Findings From the U.S. Scoliosis Cohort Study","volume":"25","author":"M Morin Doody","year":"2000","journal-title":"Spine"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1016\/j.ejrad.2015.12.032","article-title":"Cumulative radiation exposure and associated cancer risk estimates for scoliosis patients: Impact of repetitive full spine radiography","volume":"85","author":"M Law","year":"2016","journal-title":"Eur J Radiol"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"3123","DOI":"10.1007\/s00586-020-06573-7","article-title":"Cancer and mortality risks of patients with scoliosis from radiation exposure: a systematic review and meta-analysis","volume":"29","author":"FJ Luan","year":"2020","journal-title":"Eur Spine J"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1007\/s00247-011-2293-y","article-title":"Diagnostic errors from digital stitching of scoliosis images \u2013 the importance of evaluating the source images prior to making a final diagnosis","volume":"42","author":"N Supakul","year":"2012","journal-title":"Pediatr Radiol"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1097\/BRS.0b013e3181bdcaa4","article-title":"Diagnostic Imaging of Spinal Deformities: Reducing Patients Radiation Dose With a New Slot-Scanning X-ray Imager","volume":"35","author":"S Desch\u00eanes","year":"2010","journal-title":"Spine"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1186\/s13013-016-0106-7","article-title":"Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD \u201cJohn Sevastic Award\u201d Winner in Imaging Research","volume":"11","author":"SCN Hui","year":"2016","journal-title":"Scoliosis Spinal Disord"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.1007\/s00586-018-5464-9","article-title":"Dose, image quality and spine modeling assessment of biplanar EOS micro-dose radiographs for the follow-up of in-brace adolescent idiopathic scoliosis patients","volume":"27","author":"B Morel","year":"2018","journal-title":"Eur Spine J"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1016\/j.diii.2015.06.018","article-title":"Radiography of scoliosis: Comparative dose levels and image quality between a dynamic flat-panel detector and a slot-scanning device (EOS system)","volume":"96","author":"M Yvert","year":"2015","journal-title":"Diagn Interv Imaging"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1037\/1040-3590.6.4.284","article-title":"Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology","volume":"6","author":"DV Cicchetti","year":"1994","journal-title":"Psychol Assess"},{"key":"ref13","volume-title":"R: A Language and Environment for Statistical Computing","author":"R Core Team","year":"2024"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.1007\/s00586-018-5561-9","article-title":"Lowered dose full-spine radiography in pediatric patients with idiopathic scoliosis","volume":"27","author":"C Ernst","year":"2018","journal-title":"Eur Spine J"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/j.ejrad.2009.05.060","article-title":"Digital radiography: The balance between image quality and required radiation dose","volume":"72","author":"M Uffmann","year":"2009","journal-title":"Eur J Radiol"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"mp.14680","DOI":"10.1002\/mp.14680","article-title":"A phantom study on dose efficiency for orthopedic applications: Comparing slot-scanning radiography using ultra-small-angle tomosynthesis to conventional radiography","author":"C Luckner","year":"2020","journal-title":"Med Phys"}],"container-title":["R\u00f6Fo - Fortschritte auf dem Gebiet der R\u00f6ntgenstrahlen und der bildgebenden Verfahren"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2564-0580.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T23:49:43Z","timestamp":1769644183000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2564-0580"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,25]]},"references-count":14,"journal-issue":{"issue":"02","published-online":{"date-parts":[[2026,1,28]]},"published-print":{"date-parts":[[2026,2]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2564-0580","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["1438-9029","1438-9010"],"issn-type":[{"value":"1438-9029","type":"print"},{"value":"1438-9010","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,25]]}}}