{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T23:35:24Z","timestamp":1779406524225,"version":"3.53.1"},"reference-count":17,"publisher":"Georg Thieme Verlag KG","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Wrist Surg"],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Extensor carpi ulnaris (ECU) instability can be treated with subsheath reconstruction using the extensor retinaculum (ER). This cadaveric study studied two described techniques of radial- (RBR) and ulnar-based (UBR) extensor retinaculum reconstruction of the ECU subsheath.<\/jats:p>\n                  <jats:p>The ECU subsheath and ER were exposed on 12 fresh frozen arms. Transverse and oblique RBR and UBR based on the ulnar aspect of the fifth dorsal compartment were created and measured. The transverse RBR and UBR were elevated from the ulnar aspect of the ulnar styloid and Lister's tubercle, respectively. The oblique RBR and UBR were elevated from the insertion of the retinaculum onto the flexor carpi ulnaris and the radial border of the second dorsal compartment, respectively.<\/jats:p>\n                  <jats:p>The mean styloid to styloid width for the ER was 50.3\u2009\u00b1\u20091.8\u2009mm. Mean proximal to distal retinacular height was found to be 30.6\u2009\u00b1\u20092.0\u2009mm. The mean transverse UBR (26.1\u2009mm) was longer than the mean transverse RBR (18.3\u2009mm), and the mean oblique UBR (36.0\u2009mm) was longer than the mean oblique RBR (21.6\u2009mm). All reconstructions were long enough to wrap around the ECU tendon and prevent the tendon from subluxating palmarly with wrist supination, ulnar deviation, and flexion.<\/jats:p>\n                  <jats:p>In this cadaveric model, UBR and RBR of the ECU subsheath were sufficient to stabilize the ECU tendon, but UBR were significantly longer than RBR. Both reconstructions pull the ECU radially in pronation.<\/jats:p>","DOI":"10.1055\/a-2622-5102","type":"journal-article","created":{"date-parts":[[2025,6,23]],"date-time":"2025-06-23T19:09:56Z","timestamp":1750705796000},"page":"216-222","source":"Crossref","is-referenced-by-count":0,"title":["Radial- versus Ulnar-Based Extensor Retinaculum Reconstruction for Extensor Carpi Ulnaris Instability: A Cadaveric Study"],"prefix":"10.1055","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1270-4200","authenticated-orcid":false,"given":"Daniel Y.","family":"Hong","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Columbia University Medical Center, New York City, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taylor L.","family":"Paskey","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Columbia University Medical Center, New York City, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Varun","family":"Arvind","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Columbia University Medical Center, New York City, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert J.","family":"Strauch","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Columbia University Medical Center, New York City, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2025,6,23]]},"reference":[{"issue":"04","key":"ref1","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1016\/j.hcl.2021.06.005","article-title":"Extensor carpi ulnaris subluxation","volume":"37","author":"J N Byrd","year":"2021","journal-title":"Hand Clin"},{"issue":"06","key":"ref2","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1054\/jhsb.2001.0615","article-title":"Surgical treatment for recurrent dislocation of the extensor carpi ulnaris tendon","volume":"26","author":"G Inoue","year":"2001","journal-title":"J Hand Surg [Br]"},{"issue":"02","key":"ref3","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1136\/bjsm.32.2.172","article-title":"Recurrent dislocation of the extensor carpi ulnaris tendon","volume":"32","author":"G Inoue","year":"1998","journal-title":"Br J Sports Med"},{"issue":"02","key":"ref4","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.jhsa.2015.10.024","article-title":"Relative contribution of the subsheath to extensor carpi ulnaris tendon stability: implications for surgical reconstruction and rehabilitation","volume":"41","author":"A C Ghatan","year":"2016","journal-title":"J Hand Surg Am"},{"issue":"10","key":"ref5","doi-asserted-by":"crossref","first-page":"837.e1","DOI":"10.1016\/j.jhsa.2017.06.007","article-title":"A biomechanical comparison of extensor carpi ulnaris subsheath reconstruction techniques","volume":"42","author":"S K Puri","year":"2017","journal-title":"J Hand Surg Am"},{"issue":"06","key":"ref6","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1177\/15589447231151433","article-title":"Radially based extensor retinacular sling reconstruction for extensor carpi ulnaris subsheath injuries in elite athletes","volume":"19","author":"M A Mastroianni","year":"2024","journal-title":"Hand (N Y)"},{"issue":"01","key":"ref7","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1097\/BTH.0000000000000257","article-title":"Long-term outcomes after extensor carpi ulnaris subsheath reconstruction with extensor retinaculum","volume":"24","author":"S HWL Verhiel","year":"2020","journal-title":"Tech Hand Up Extrem Surg"},{"issue":"11","key":"ref8","doi-asserted-by":"crossref","first-page":"e433","DOI":"10.1016\/j.jhsa.2016.08.009","article-title":"Extensor carpi ulnaris subsheath reconstruction","volume":"41","author":"D E Ruchelsman","year":"2016","journal-title":"J Hand Surg Am"},{"issue":"03","key":"ref9","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1177\/15589447221105539","article-title":"An analysis of extensor carpi ulnaris groove morphology and tendon instability","volume":"19","author":"S C Shoap","year":"2024","journal-title":"Hand (N Y)"},{"issue":"02","key":"ref10","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1142\/S0218810404002212","article-title":"Extensor carpi ulnaris subluxation or dislocation? Ultrasound measurement of tendon excursion and normal values","volume":"9","author":"R K Pratt","year":"2004","journal-title":"Hand Surg"},{"issue":"03","key":"ref11","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1177\/03635465030310032301","article-title":"Extensor carpi ulnaris tendon rupture in an ice hockey player: a case report","volume":"31","author":"C Wang","year":"2003","journal-title":"Am J Sports Med"},{"issue":"04","key":"ref12","first-page":"399","article-title":"Non rheumatoid closed rupture of extensor carpi ulnaris tendon. Report of a case in a professional athlete","volume":"68","author":"K C Xarchas","year":"2002","journal-title":"Acta Orthop Belg"},{"issue":"68","key":"ref13","first-page":"124","article-title":"Extensor carpi ulnaris. Its relationship to the stability of the distal radio-ulnar joint","volume":"68","author":"M Spinner","year":"1970","journal-title":"Clin Orthop Relat Res"},{"issue":"06","key":"ref14","doi-asserted-by":"crossref","first-page":"896","DOI":"10.1016\/j.jhsa.2006.02.026","article-title":"An anatomic and biomechanic study of the wrist extensor retinaculum septa and tendon compartments","volume":"31","author":"A Iwamoto","year":"2006","journal-title":"J Hand Surg Am"},{"issue":"03","key":"ref15","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1159\/000145999","article-title":"The attachments of the lateral and medial ends of the extensor retinaculum of the human wrist","volume":"122","author":"S S Salman","year":"1985","journal-title":"Acta Anat (Basel)"},{"issue":"04","key":"ref16","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/S0363-5023(84)80100-8","article-title":"The extensor retinaculum of the wrist","volume":"9","author":"J Taleisnik","year":"1984","journal-title":"J Hand Surg Am"},{"issue":"02","key":"ref17","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/S0363-5023(05)80030-9","article-title":"Ligamentous and tendinous support of the pisiform, anatomic and biomechanical study","volume":"20","author":"T Pevny","year":"1995","journal-title":"J Hand Surg Am"}],"container-title":["Journal of Wrist Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2622-5102.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T22:55:15Z","timestamp":1779404115000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2622-5102"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,23]]},"references-count":17,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2026,5,21]]},"published-print":{"date-parts":[[2026,6]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2622-5102","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["2163-3916","2163-3924"],"issn-type":[{"value":"2163-3916","type":"print"},{"value":"2163-3924","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,23]]}}}