{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T03:08:25Z","timestamp":1773889705652,"version":"3.50.1"},"reference-count":16,"publisher":"Georg Thieme Verlag KG","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Klin Monbl Augenheilkd"],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Background Visual field testing is essential for glaucoma diagnostics; however, patient cooperation can affect the reliability of the results. The COMPASS perimeter (COM; CentreVue-iCare, Padua, Italy) offers an innovative approach to enhance test quality by compensating for fixation losses and automatically adjusting light stimuli. Additionally, it enables simultaneous fundus photography during perimetry. In this prospective study, we compare the COM perimeter with the Humphrey Field Analyzer (HFA) in glaucoma patients and healthy subjects in terms of visual field parameters, reproducibility, and patient satisfaction. The aim is to evaluate the clinical applicability and potential added value of the COM perimeter.<\/jats:p>\n                  <jats:p>Materials and Methods 113 eyes (67 glaucoma, 46 healthy) were tested using both COM (24\u200a\u2013\u200a2 ZEST) and HFA (24\u200a\u2013\u200a2 SITA-Standard). Mean deviation (MD), pattern standard deviation (PSD), test duration (TD), and subjective patient experiences were recorded. Reproducibility was assessed by analysing repeated measurements in ten healthy subjects.<\/jats:p>\n                  <jats:p>Results In the overall cohort, the COM measured a mean deviation (MD) of \u2212\u20092.8\u2009\u00b1\u20095.7\u2009dB and a pattern standard deviation (PSD) of 4.3\u2009\u00b1\u20093.5\u2009dB. In comparison, the HFA showed an MD of \u2212\u20094.4\u2009\u00b1\u20095.6\u2009dB and a PSD of 3.2\u2009\u00b1\u20093.1\u2009dB. The average test duration was 412\u2009\u00b1\u200994 seconds for COM and 341\u2009\u00b1\u200972 seconds for HFA. Subjective patient satisfaction was significantly higher with COM (p\u2009&lt;\u20090.00\u200a001) than with HFA. Both tests demonstrated high reproducibility with no significant differences in repeated measurements.<\/jats:p>\n                  <jats:p>Conclusions The COM perimeter and the HFA Field Analyser demonstrated significant differences in the parameters MD, PSD, and test duration. Higher patient satisfaction and potentially better diagnostic specificity suggest that COM is a promising method for detecting visual field defects in glaucoma patients. The observed higher specificity of the COM perimeter may be attributed to its integrated eye-tracking system. The use and further refinement of this technology could enable greater precision in glaucoma diagnostics in clinical practice.<\/jats:p>","DOI":"10.1055\/a-2729-7463","type":"journal-article","created":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T22:48:10Z","timestamp":1761173290000},"page":"220-228","source":"Crossref","is-referenced-by-count":0,"title":["Humphrey vs. Compass: A Comparative Study of Two Perimetry Devices"],"prefix":"10.1055","volume":"243","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-9080-4084","authenticated-orcid":false,"given":"Antoine","family":"Capucci","sequence":"additional","affiliation":[{"name":"Augenzentrum am St.\u00a0Franziskus-Hospital M\u00fcnster, M\u00fcnster, Deutschland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4288-8795","authenticated-orcid":false,"given":"Kai","family":"Rothaus","sequence":"additional","affiliation":[{"name":"Augenzentrum am St.\u00a0Franziskus-Hospital M\u00fcnster, M\u00fcnster, Deutschland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefanie","family":"M\u00fcller","sequence":"additional","affiliation":[{"name":"Augenzentrum am St.\u00a0Franziskus-Hospital M\u00fcnster, M\u00fcnster, Deutschland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9358-249X","authenticated-orcid":false,"given":"Claudia","family":"Lommatzsch","sequence":"additional","affiliation":[{"name":"Augenzentrum am St.\u00a0Franziskus-Hospital M\u00fcnster, M\u00fcnster, Deutschland"},{"name":"Universit\u00e4ts-Augenklinik L\u00fcbeck, UKSH, L\u00fcbeck, Deutschland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2026,1,26]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.ajo.2016.11.010","article-title":"Estimating Optical Coherence Tomography Structural Measurement Floors to Improve Detection of Progression in Advanced Glaucoma","volume":"175","author":"C Bowd","year":"2017","journal-title":"Am J Ophthalmol"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1136\/bjophthalmol-2017-310309","article-title":"The association between ocular surface measurements with visual field reliability indices and gaze tracking results in preperimetric glaucoma","volume":"102","author":"T Arai","year":"2018","journal-title":"Br J Ophthalmol"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1001\/jamaophthalmol.2017.1279","article-title":"Association Between Neurocognitive Decline and Visual Field Variability in Glaucoma","volume":"135","author":"A Diniz-Filho","year":"2017","journal-title":"JAMA Ophthalmol"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1167\/tvst.11.8.3","article-title":"Long- and Short-Term Variability of Perimetry in Glaucoma","volume":"11","author":"S K Gardiner","year":"2022","journal-title":"Transl Vis Sci Technol"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1016\/j.ophtha.2018.08.010","article-title":"A Comparison between the Compass Fundus Perimeter and the Humphrey Field Analyzer","volume":"126","author":"G Montesano","year":"2019","journal-title":"Ophthalmology"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1016\/s0166-4328(01)00297-2","article-title":"Controlling the false discovery rate in behavior genetics research","volume":"125","author":"Y Benjamini","year":"2001","journal-title":"Behav Brain Res"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"4414","DOI":"10.3390\/jcm10194414","article-title":"Global glaucoma staging system (GGSS): A new method to simultaneously assess the severity of both functional and structural damage in glaucoma","volume":"10","author":"P Brusini","year":"2021","journal-title":"J Clin Med"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"598","DOI":"10.5301\/ejo.5000821","article-title":"Comparison of Compass and Humphrey perimeters in detecting glaucomatous defects","volume":"26","author":"P Fogagnolo","year":"2016","journal-title":"Eur J Ophthalmol"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"e0122157","DOI":"10.1371\/journal.pone.0122157","article-title":"Compass: Clinical evaluation of a new instrument for the diagnosis of glaucoma","volume":"10","author":"L Rossetti","year":"2015","journal-title":"PLoS One"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.ajo.2005.07.044","article-title":"Categorizing the stage of glaucoma from pre-diagnosis to end-stage disease","volume":"141","author":"R P Mills","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"4787","DOI":"10.1167\/iovs.03-0023","article-title":"Properties of Perimetric Threshold Estimates from Full Threshold, ZEST, and SITA-like Strategies, as Determined by Computer Simulation","volume":"44","author":"A Turpin","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1001\/archopht.1996.01100130017003","article-title":"The effect of perimetric experience in patients with glaucoma","volume":"114","author":"A Heijl","year":"1996","journal-title":"Arch Ophthalmol"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1097\/IJG.0000000000000609","article-title":"Comparing the performance of compass perimetry with Humphrey field analyzer in eyes with glaucoma","volume":"26","author":"H L Rao","year":"2017","journal-title":"J Glaucoma"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.ogla.2022.08.017","article-title":"Comparison of 10\u20132 and 24-2 Perimetry to Diagnose Glaucoma Using OCT as an Independent Reference Standard","volume":"6","author":"N AE Onyekaba","year":"2023","journal-title":"Ophthalmol Glaucoma"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1167\/tvst.13.6.19","article-title":"A Practical Framework for the Integration of Structural Data Into Perimetric Examinations","volume":"13","author":"J C Evans","year":"2024","journal-title":"Transl Vis Sci Technol"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"1850","DOI":"10.1177\/1120672120945052","article-title":"Comparison between Fundus Automated Perimetry and Humphrey Field Analyzer: Performance and usability of the Fundus Automated Perimetry and Humphrey Field Analyzer in healthy, ocular hypertensive, and glaucomatous patients","volume":"31","author":"R Morbio","year":"2021","journal-title":"Eur J Ophthalmol"}],"container-title":["Klinische Monatsbl\u00e4tter f\u00fcr Augenheilkunde"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2729-7463.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T23:32:24Z","timestamp":1773876744000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2729-7463"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,22]]},"references-count":16,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2026,3,18]]},"published-print":{"date-parts":[[2026,3]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2729-7463","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0023-2165","1439-3999"],"issn-type":[{"value":"0023-2165","type":"print"},{"value":"1439-3999","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2025,10,22]]},"published":{"date-parts":[[2025,10,22]]}}}