{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T22:47:32Z","timestamp":1776725252275,"version":"3.51.2"},"reference-count":24,"publisher":"Georg Thieme Verlag KG","issue":"04","license":[{"start":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T00:00:00Z","timestamp":1771804800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Klin Monbl Augenheilkd"],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Background Accurate ocular biometry is essential for achieving optimal refractive outcomes in cataract surgery. In patients with prior myopic LASIK, however, biometric calculations remain particularly challenging due to altered corneal anatomy.<\/jats:p>\n                  <jats:p>Purpose This study aims to compare preoperative biometric measurements obtained from the Zeiss IOL Master 700 and the CSO Ray-Tracing MS-39 in patients with a history of myopic LASIK. The goal is to assess the consistency and clinical relevance of these measurements to support intraocular lens (IOL) power selection in this complex patient group.<\/jats:p>\n                  <jats:p>Setting Longitudinal, monocentric, retrospective study, conducted at the Ophthalmology Department of the University Hospital of Modena.<\/jats:p>\n                  <jats:p>Methods Patients over 18 years of age scheduled for cataract surgery with a history of myopic LASIK and available preoperative biometry from both the IOL Master 700 and MS-39 were included. Exclusion criteria were incomplete clinical records, prior intraocular surgery, or significant ocular pathologies affecting measurement accuracy. The primary outcomes were differences in calculated emmetropic IOL power and predicted postoperative refraction. Secondary outcomes included comparisons of anterior chamber depth (ACD), central corneal thickness (CCT), average keratometry (K-avg), total corneal power (total keratometry [TK] from IOL Master 700 vs. mean pupil power [MMP] from MS-39), and predicted post-operative spherical equivalent (SE) by using the same IOL power, calculated from the IOL Master 700.<\/jats:p>\n                  <jats:p>Results Seventy-six eyes from 41 patients (mean age 46.54\u2009\u00b1\u200912.70 years; 60.98% female) were analysed. The average axial length was 25.93\u2009\u00b1\u20091.55\u2009mm. An IOL constant of 119.0 was used uniformly across both devices. Statistically significant differences were found in all biometric parameters: ACD (p\u2009=\u20090.00\u200a001), CCT (p\u2009=\u20090.0189), K-avg (p\u2009=\u20090.00\u200a009), and total keratometry (p\u2009=\u20090.00\u200a001). However, no significant differences were observed in the selected IOL power for emmetropia (p\u2009=\u20090.72\u200a527), the predicted postoperative SE of the IOL Master 700 vs. the MS-39 (p\u2009=\u20090.81\u200a642), or the predicted postoperative SE by using the same IOL power, calculated from the IOL Master 700, (p\u2009=\u20090.38\u200a938).<\/jats:p>\n                  <jats:p>Conclusions Despite statistically significant differences in individual biometric parameters between the IOL Master 700 and MS-39, these did not impact final IOL power selection or predicted refraction in post-myopic LASIK patients. Utilizing multiple biometry devices may still enhance confidence and accuracy in surgical planning for this complex group of patients.<\/jats:p>","DOI":"10.1055\/a-2763-7114","type":"journal-article","created":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T23:53:24Z","timestamp":1771890804000},"page":"353-358","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of Biometric Measurements Between IOL Master 700 and MS-39 in Post-LASIK Myopic Eyes: Implications for IOL Selection in Cataract Surgery"],"prefix":"10.1055","volume":"243","author":[{"given":"Giacomo Edoardo","family":"Bravetti","sequence":"first","affiliation":[{"name":"Ophthalmology Department, University Hospital Modena, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4756-8715","authenticated-orcid":false,"given":"Giorgio Enrico","family":"Bravetti","sequence":"first","affiliation":[{"name":"Ophthalmology Department, Geneva University Hospitals, Geneva, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7884-329X","authenticated-orcid":false,"given":"Emmanouil","family":"Blavakis","sequence":"additional","affiliation":[{"name":"Ophthalmology Department, Geneva University Hospitals, Geneva, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giacomo","family":"Savini","sequence":"additional","affiliation":[{"name":"Ophthalmology Department, G.\u200aB. Bietti Foundation I.\u200aR.\u200aC.\u200aC.\u200aS., Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gian Maria","family":"Cavallini","sequence":"additional","affiliation":[{"name":"Ophthalmology Department, University Hospital Modena, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2026,2,23]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s40662-018-0110-5","article-title":"Intraocular lens power calculation in eyes with previous corneal refractive surgery","volume":"5","author":"G Savini","year":"2018","journal-title":"Eye Vis (Lond)"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.1016\/j.jcrs.2010.03.044","article-title":"Evaluation of intraocular lens power prediction methods using the American Society of Cataract and Refractive Surgeons Post-Keratorefractive Intraocular Lens Power Calculator","volume":"36","author":"L Wang","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"22","DOI":"10.4103\/tjo.tjo_38_21","article-title":"Intraocular lens power calculations in eyes with previous corneal refractive surgery: Challenges, approaches, and outcomes","volume":"12","author":"L Wang","year":"2022","journal-title":"Taiwan J Ophthalmol"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.sjopt.2011.11.007","article-title":"Challenges and approaches in modern biometry and IOL calculation","volume":"26","author":"W Haigis","year":"2012","journal-title":"Saudi J Ophthalmol"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"331","DOI":"10.3928\/1081597X-20180214-02","article-title":"Measurement of Posterior Corneal Astigmatism by the IOLMaster 700","volume":"34","author":"B R LaHood","year":"2018","journal-title":"J Refract Surg"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1016\/j.jcrs.2011.11.037","article-title":"Accuracy of corneal power measurements by a new Scheimpflug camera combined with Placido-disk corneal topography for intraocular lens power calculation in unoperated eyes","volume":"38","author":"G Savini","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1016\/j.jcrs.2008.01.012","article-title":"Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery","volume":"34","author":"G Savini","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1016\/j.jcrs.2016.01.038","article-title":"Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device","volume":"42","author":"M Kurian","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1016\/j.ophtha.2016.01.006","article-title":"Global Prevalence of Myopia and High Myopia and Temporal Trends from 2000 through 2050","volume":"123","author":"B A Holden","year":"2016","journal-title":"Ophthalmology"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"2358","DOI":"10.1016\/j.jcrs.2015.04.034","article-title":"Cataract surgery outcomes in corneal refractive surgery eyes: Study from the European Registry of Quality Outcomes for Cataract and Refractive Surgery","volume":"41","author":"S Manning","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1097\/ICU.0000000000001006","article-title":"Cataract surgery after corneal refractive surgery: preoperative considerations and management","volume":"35","author":"D Ting","year":"2024","journal-title":"Curr Opin Ophthalmol"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"75","DOI":"10.3928\/1081-597X-20060101-15","article-title":"Intraocular lens power calculation following LASIK: determination of the new effective index of refraction","volume":"22","author":"E F Jarade","year":"2006","journal-title":"J Refract Surg"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1097\/ICU.0000000000000330","article-title":"Intraocular lens calculations after laser vision correction","volume":"28","author":"C E Perez-Straziota","year":"2017","journal-title":"Curr Opin Ophthalmol"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"1416","DOI":"10.1016\/j.jcrs.2019.05.020","article-title":"Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery","volume":"45","author":"L Wang","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1016\/j.jcrs.2018.02.015","article-title":"Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras","volume":"44","author":"G Savini","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1038\/s41433-020-01245-8","article-title":"Repeatability of total Keratometry and standard Keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging","volume":"35","author":"G Savini","year":"2021","journal-title":"Eye (Lond)"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"4010","DOI":"10.3390\/jcm14114010","article-title":"IOL Power Calculation After Laser-Based Refractive Surgery: Measured vs. Predicted Posterior Corneal Astigmatism Using the Barrett True-K Formula","volume":"14","author":"G De Rosa","year":"2025","journal-title":"J Clin Med"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"e121","DOI":"10.1016\/j.ophtha.2020.06.054","article-title":"Intraocular Lens Power Calculations in Eyes with Previous Corneal Refractive Surgery: Review and Expert Opinion","volume":"128","author":"L Wang","year":"2021","journal-title":"Ophthalmology"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.ajo.2023.05.005","article-title":"A Simplified Method to Minimize Systematic Bias of Single-Optimized Intraocular Lens Power Calculation Formulas","volume":"253","author":"D Gatinel","year":"2023","journal-title":"Am J Ophthalmol"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"7357","DOI":"10.1038\/s41598-022-11462-8","article-title":"Intraoperative aberrometry compared to preoperative Barrett True-K formula for intraocular lens power selection in eyes with prior refractive surgery","volume":"12","author":"S A Gasparian","year":"2022","journal-title":"Sci Rep"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1007\/s004170000188","article-title":"Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis","volume":"238","author":"W Haigis","year":"2000","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.ajo.2013.08.006","article-title":"Intraocular lens power calculation by ray-tracing after myopic excimer laser surgery","volume":"157","author":"G Savini","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1097\/APO.0000000000000394","article-title":"Artificial Intelligence in Cornea, Refractive Surgery, and Cataract: Basic Principles, Clinical Applications, and Future Directions","volume":"10","author":"R Rampat","year":"2021","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"e936","DOI":"10.3928\/1081597X-20250707-02","article-title":"Accuracy of PEARL-DGS Formula for Intraocular Lens Power Calculation in Patients With Previous Myopic Laser Vision Correction","volume":"41","author":"P Zollet","year":"2025","journal-title":"J Refract Surg"}],"container-title":["Klinische Monatsbl\u00e4tter f\u00fcr Augenheilkunde"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2763-7114.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T22:35:04Z","timestamp":1776724504000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2763-7114"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,23]]},"references-count":24,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2026,4,20]]},"published-print":{"date-parts":[[2026,4]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2763-7114","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0023-2165","1439-3999"],"issn-type":[{"value":"0023-2165","type":"print"},{"value":"1439-3999","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,23]]}}}