{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T23:07:02Z","timestamp":1775516822109,"version":"3.50.1"},"reference-count":47,"publisher":"Georg Thieme Verlag KG","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Colon Rectal Surg"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Colorectal cancer incidence and mortality have declined over time, due in part to high-quality screening and surveillance colonoscopy. Nevertheless, postcolonoscopy colorectal cancer (PCCRC) occurs in up to 7% of cases and is inversely related to examination quality. Artificial intelligence-assisted colonoscopy aims to improve performance metrics and, ultimately, patient outcomes. Multiple randomized trials show that computer-aided polyp detection (CADe) increases adenoma detection, predominantly for diminutive lesions (\u22645\u2009mm). Computer-aided polyp characterization (CADx) enables real-time optical diagnosis, potentially shifting management of diminutive polyps by supporting resect-and-discard and diagnose-and-leave in situ strategies. Computer-aided quality assessment (CAQ) systems monitor key metrics\u2014including cecal intubation rate, withdrawal time, speed, and mucosal exposure. Whether CADe alone leads to a reduction in PCCRC or cancer-related mortality remains to be determined; in the near term, a combined approach using CADe, CADx, and CAQ is most likely to deliver the greatest improvements in patient outcomes.<\/jats:p>","DOI":"10.1055\/a-2769-1233","type":"journal-article","created":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T23:55:31Z","timestamp":1767830131000},"page":"209-214","source":"Crossref","is-referenced-by-count":0,"title":["Artificial Intelligence and Its Role in Endoscopic Adenoma and Cancer Detection"],"prefix":"10.1055","volume":"39","author":[{"given":"Hannah R.","family":"Phillips","sequence":"additional","affiliation":[{"name":"Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wilfor J.","family":"Diaz Fernandez","sequence":"additional","affiliation":[{"name":"Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cadman L.","family":"Leggett","sequence":"additional","affiliation":[{"name":"Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2026,1,7]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"g2467","DOI":"10.1136\/bmj.g2467","article-title":"Effect of screening sigmoidoscopy and screening colonoscopy on colorectal cancer incidence and mortality: systematic review and meta-analysis of randomised controlled trials and observational studies","volume":"348","author":"H Brenner","year":"2014","journal-title":"BMJ"},{"issue":"03","key":"ref2","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1053\/j.gastro.2018.05.038","article-title":"World Endoscopy Organization consensus statements on post-colonoscopy and post-imaging colorectal cancer","volume":"155","author":"M D Rutter","year":"2018","journal-title":"Gastroenterology"},{"issue":"06","key":"ref3","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1136\/gutjnl-2012-303796","article-title":"Colorectal cancers soon after colonoscopy: a pooled multicohort analysis","volume":"63","author":"D J Robertson","year":"2014","journal-title":"Gut"},{"issue":"14","key":"ref4","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1056\/NEJMoa1309086","article-title":"Adenoma detection rate and risk of colorectal cancer and death","volume":"370","author":"D A Corley","year":"2014","journal-title":"N Engl J Med"},{"issue":"09","key":"ref5","doi-asserted-by":"crossref","first-page":"1754","DOI":"10.14309\/ajg.0000000000002972","article-title":"Quality indicators for colonoscopy","volume":"119","author":"D K Rex","year":"2024","journal-title":"Am J Gastroenterol"},{"issue":"12","key":"ref6","doi-asserted-by":"crossref","first-page":"1652","DOI":"10.7326\/ANNALS-24-00981","article-title":"Artificial intelligence-assisted colonoscopy for polyp detection: a systematic review and meta-analysis","volume":"177","author":"S Soleymanjahi","year":"2024","journal-title":"Ann Intern Med"},{"issue":"01","key":"ref7","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.gie.2024.08.033","article-title":"Use of artificial intelligence improves colonoscopy performance in adenoma detection: a systematic review and meta-analysis","volume":"101","author":"J Makar","year":"2025","journal-title":"Gastrointest Endosc"},{"issue":"02","key":"ref8","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/S0169-2607(02)00007-X","article-title":"CoLD: a versatile detection system for colorectal lesions in endoscopy video-frames","volume":"70","author":"D E Maroulis","year":"2003","journal-title":"Comput Methods Programs Biomed"},{"issue":"04","key":"ref9","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1053\/j.gastro.2018.06.037","article-title":"Deep learning localizes and identifies polyps in real time with 96% accuracy in screening colonoscopy","volume":"155","author":"G Urban","year":"2018","journal-title":"Gastroenterology"},{"issue":"10","key":"ref10","doi-asserted-by":"crossref","first-page":"1813","DOI":"10.1136\/gutjnl-2018-317500","article-title":"Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study","volume":"68","author":"P Wang","year":"2019","journal-title":"Gut"},{"issue":"02","key":"ref11","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1053\/j.gastro.2020.04.062","article-title":"Efficacy of real-time computer-aided detection of colorectal neoplasia in a randomized trial","volume":"159","author":"A Repici","year":"2020","journal-title":"Gastroenterology"},{"issue":"05","key":"ref12","doi-asserted-by":"crossref","first-page":"797","DOI":"10.3390\/cancers17050797","article-title":"AI and polyp detection during colonoscopy","volume":"17","author":"M Spadaccini","year":"2025","journal-title":"Cancers (Basel)"},{"issue":"10","key":"ref13","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1055\/a-1770-7353","article-title":"The influence of computer-aided polyp detection systems on reaction time for polyp detection and eye gaze","volume":"54","author":"J Troya","year":"2022","journal-title":"Endoscopy"},{"issue":"10","key":"ref14","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1038\/s41551-018-0301-3","article-title":"Development and validation of a deep-learning algorithm for the detection of polyps during colonoscopy","volume":"2","author":"P Wang","year":"2018","journal-title":"Nat Biomed Eng"},{"issue":"04","key":"ref15","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/S2468-1253(19)30411-X","article-title":"Effect of a deep-learning computer-aided detection system on adenoma detection during colonoscopy (CADe-DB trial): a double-blind randomised study","volume":"5","author":"P Wang","year":"2020","journal-title":"Lancet Gastroenterol Hepatol"},{"issue":"07","key":"ref16","doi-asserted-by":"crossref","first-page":"1499","DOI":"10.1016\/j.cgh.2021.09.009","article-title":"Deep learning computer-aided polyp detection reduces adenoma miss rate: a United States multi-center randomized tandem colonoscopy study (CADeT-CS Trial)","volume":"20","author":"J R Glissen Brown","year":"2022","journal-title":"Clin Gastroenterol Hepatol"},{"issue":"10","key":"ref17","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1016\/S2468-1253(24)00161-4","article-title":"Polyp detection with colonoscopy assisted by the GI Genius artificial intelligence endoscopy module compared with standard colonoscopy in routine colonoscopy practice (COLO-DETECT): a multicentre, open-label, parallel-arm, pragmatic randomised controlled trial","volume":"9","author":"A Seager","year":"2024","journal-title":"Lancet Gastroenterol Hepatol"},{"issue":"12","key":"ref18","doi-asserted-by":"crossref","first-page":"1974","DOI":"10.1136\/gutjnl-2024-331943","article-title":"Clinical consequences of computer-aided colorectal polyp detection","volume":"73","author":"P Sinonquel","year":"2024","journal-title":"Gut"},{"issue":"01","key":"ref19","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.gie.2020.06.059","article-title":"Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis","volume":"93","author":"C Hassan","year":"2021","journal-title":"Gastrointest Endosc"},{"issue":"09","key":"ref20","doi-asserted-by":"crossref","first-page":"1209","DOI":"10.7326\/M22-3678","article-title":"Real-time computer-aided detection of colorectal neoplasia during colonoscopy: a systematic review and meta-analysis","volume":"176","author":"C Hassan","year":"2023","journal-title":"Ann Intern Med"},{"issue":"01","key":"ref21","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.dld.2024.09.003","article-title":"Effectiveness of artificial intelligence assisted colonoscopy on adenoma and polyp miss rate: a meta-analysis of tandem RCTs","volume":"57","author":"M Maida","year":"2025","journal-title":"Dig Liver Dis"},{"issue":"06","key":"ref22","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1016\/j.dld.2025.01.192","article-title":"Variability in computer-aided detection effect on adenoma detection rate in randomized controlled trials: a meta-regression analysis","volume":"57","author":"M Spadaccini","year":"2025","journal-title":"Dig Liver Dis"},{"issue":"11","key":"ref23","doi-asserted-by":"crossref","first-page":"1871","DOI":"10.14309\/ajg.0000000000001970","article-title":"Artificial intelligence-aided colonoscopy does not increase adenoma detection rate in routine clinical practice","volume":"117","author":"I Levy","year":"2022","journal-title":"Am J Gastroenterol"},{"issue":"03","key":"ref24","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1053\/j.gastro.2022.12.004","article-title":"Computer-aided detection of polyps does not improve colonoscopist performance in a pragmatic implementation trial","volume":"164","author":"U Ladabaum","year":"2023","journal-title":"Gastroenterology"},{"issue":"05","key":"ref25","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1016\/j.cgh.2023.11.029","article-title":"Lack of effectiveness of computer aided detection for colorectal neoplasia: a systematic review and meta-analysis of nonrandomized studies","volume":"22","author":"H K Patel","year":"2024","journal-title":"Clin Gastroenterol Hepatol"},{"issue":"04","key":"ref26","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1053\/j.gastro.2025.01.002","article-title":"AGA living clinical practice guideline on computer-aided detection-assisted colonoscopy","volume":"168","author":"S Sultan","year":"2025","journal-title":"Gastroenterology"},{"issue":"05","key":"ref27","doi-asserted-by":"crossref","first-page":"638","DOI":"10.5946\/ce.2025.022","article-title":"Clinical significance of computer-aided quality assessment systems in colonoscopy: a comprehensive review","volume":"58","author":"W P Lwin","year":"2025","journal-title":"Clin Endosc"},{"issue":"19","key":"ref28","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1056\/NEJMoa0907667","article-title":"Quality indicators for colonoscopy and the risk of interval cancer","volume":"362","author":"M F Kaminski","year":"2010","journal-title":"N Engl J Med"},{"issue":"03","key":"ref29","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1016\/j.gie.2024.04.2905","article-title":"Quality indicators for colonoscopy","volume":"100","author":"D K Rex","year":"2024","journal-title":"Gastrointest Endosc"},{"issue":"04","key":"ref30","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1016\/S2468-1253(19)30413-3","article-title":"Detection of colorectal adenomas with a real-time computer-aided system (ENDOANGEL): a randomised controlled study","volume":"5","author":"D Gong","year":"2020","journal-title":"Lancet Gastroenterol Hepatol"},{"issue":"02","key":"ref31","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1016\/j.gie.2024.09.019","article-title":"Effect of a novel artificial intelligence-based cecum recognition system on adenoma detection metrics in a screening colonoscopy setting","volume":"101","author":"W F Hsu","year":"2025","journal-title":"Gastrointest Endosc"},{"issue":"04","key":"ref32","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1016\/j.gie.2010.06.068","article-title":"Comprehensive validation of the Boston Bowel Preparation Scale","volume":"72","author":"A H Calderwood","year":"2010","journal-title":"Gastrointest Endosc"},{"issue":"02","key":"ref33","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/j.gie.2019.11.026","article-title":"A novel artificial intelligence system for the assessment of bowel preparation (with video)","volume":"91","author":"J Zhou","year":"2020","journal-title":"Gastrointest Endosc"},{"issue":"05","key":"ref34","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1053\/j.gastro.2019.12.035","article-title":"Use of artificial intelligence-based analytics from live colonoscopies to optimize the quality of the colonoscopy examination in real time: proof of concept","volume":"158","author":"S Thakkar","year":"2020","journal-title":"Gastroenterology"},{"issue":"03","key":"ref35","doi-asserted-by":"crossref","first-page":"502.e1","DOI":"10.1016\/j.gie.2014.12.022","article-title":"ASGE Technology Committee systematic review and meta-analysis assessing the ASGE PIVI thresholds for adopting real-time endoscopic assessment of the histology of diminutive colorectal polyps","volume":"81","author":"B K Abu Dayyeh","year":"2015","journal-title":"Gastrointest Endosc"},{"issue":"05","key":"ref36","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1002\/ueg2.12108","article-title":"Current status and limitations of artificial intelligence in colonoscopy","volume":"9","author":"A Hann","year":"2021","journal-title":"United European Gastroenterol J"},{"issue":"06","key":"ref37","doi-asserted-by":"crossref","first-page":"357","DOI":"10.7326\/M18-0249","article-title":"Real-time use of artificial intelligence in identification of diminutive polyps during colonoscopy: a prospective study","volume":"169","author":"Y Mori","year":"2018","journal-title":"Ann Intern Med"},{"issue":"06","key":"ref38","doi-asserted-by":"crossref","first-page":"a2200003","DOI":"10.1056\/EVIDoa2200003","article-title":"Real-time artificial intelligence\u2013based optical diagnosis of neoplastic polyps during colonoscopy","volume":"1","author":"I Barua","year":"2022","journal-title":"NEJM Evid"},{"issue":"09","key":"ref39","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1080\/00365521.2018.1501092","article-title":"Optical classification of neoplastic colorectal polyps - a computer-assisted approach (the COACH study)","volume":"53","author":"J Renner","year":"2018","journal-title":"Scand J Gastroenterol"},{"issue":"07","key":"ref40","doi-asserted-by":"crossref","first-page":"e27370","DOI":"10.2196\/27370","article-title":"Diagnostic accuracy of artificial intelligence and computer-aided diagnosis for the detection and characterization of colorectal polyps: systematic review and meta-analysis","volume":"23","author":"S Nazarian","year":"2021","journal-title":"J Med Internet Res"},{"issue":"04","key":"ref41","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1016\/j.cgh.2024.08.021","article-title":"Accuracy of computer-aided diagnosis in colonoscopy varies according to polyp location: a systematic review and meta-analysis","volume":"23","author":"T Rizkala","year":"2025","journal-title":"Clin Gastroenterol Hepatol"},{"issue":"02","key":"ref42","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1055\/a-1372-0419","article-title":"Performance of a new integrated computer-assisted system (CADe\/CADx) for detection and characterization of colorectal neoplasia","volume":"54","author":"J Weigt","year":"2022","journal-title":"Endoscopy"},{"issue":"01","key":"ref43","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1038\/s41746-022-00633-6","article-title":"A novel AI device for real-time optical characterization of colorectal polyps","volume":"5","author":"C Biffi","year":"2022","journal-title":"NPJ Digit Med"},{"issue":"03","key":"ref44","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1016\/j.gie.2021.03.936","article-title":"Artificial intelligence-enhanced white-light colonoscopy with attention guidance predicts colorectal cancer invasion depth","volume":"94","author":"X Luo","year":"2021","journal-title":"Gastrointest Endosc"},{"key":"ref45","first-page":"113","article-title":"Deskilling of endoscopists caused by implementation of artificial intelligence in colonoscopy: a multicenter observational study","volume":"12","author":"K Budzyn","year":"2024","journal-title":"United Eur Gastroenterol"},{"issue":"06","key":"ref46","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1016\/j.gie.2024.06.029","article-title":"Appropriate trust in artificial intelligence for the optical diagnosis of colorectal polyps: the role of human\/artificial intelligence interaction","volume":"100","author":"Q EW van der Zander","year":"2024","journal-title":"Gastrointest Endosc"},{"issue":"05","key":"ref47","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1159\/000544030","article-title":"Artificial intelligence in colonoscopy: where are we now in 2024?","volume":"106","author":"W Y Lai","year":"2025","journal-title":"Digestion"}],"container-title":["Clinics in Colon and Rectal Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2769-1233.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T22:39:40Z","timestamp":1775515180000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2769-1233"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,7]]},"references-count":47,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2026,4,6]]},"published-print":{"date-parts":[[2026,5]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2769-1233","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["1531-0043","1530-9681"],"issn-type":[{"value":"1531-0043","type":"print"},{"value":"1530-9681","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,7]]}}}