{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T22:47:25Z","timestamp":1776725245815,"version":"3.51.2"},"reference-count":16,"publisher":"Georg Thieme Verlag KG","issue":"04","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Klin Monbl Augenheilkd"],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Background The Tecnis Eyhance Toric intraocular lens (IOL) model DIU00 (Johnson &amp; Johnson) is a monofocal IOL with a slightly enhanced depth of focus, designed to improve intermediate vision while correcting corneal astigmatism in cataract surgery. While its optical concept has been validated in clinical trials, evidence from routine practice is still limited. The purpose of this study was to evaluate real-world visual and refractive outcomes, postoperative astigmatism, and patient satisfaction following implantation of the Eyhance Toric IOL.<\/jats:p>\n                  <jats:p>Methods A total of 160 eyes from 97 consecutive patients were analysed, including 63 patients who underwent a bilateral procedure and 34 who had unilateral surgery with Eyhance Toric implantation. Preoperative biometry comprised axial length, anterior chamber depth, lens thickness, sulcus-to-sulcus distance, and keratometry values. At 1 month, monocular and binocular visual acuities (uncorrected [UDVA], corrected [CDVA], uncorrected intermediate [UIVA], distance-corrected intermediate [DCIVA], uncorrected near [UNVA], distance-corrected near [DCNVA]), manifest refraction, and keratometry were evaluated.<\/jats:p>\n                  <jats:p>Results At 1 month, mean monocular UDVA, CDVA, UIVA, DCIVA, and UNVA were 0.12, 0.05, 0.06, 0.07, and 0.29\u2009logMAR, respectively. Binocular UDVA, UIVA, and UNVA were 0.04, 0.03, and 0.24\u2009logMAR, respectively. Mean corneal astigmatism decreased from \u2212\u20091.70\u2009\u00b1\u20090.91\u2009D to a postoperative refractive astigmatism of 0.31\u2009\u00b1\u20090.24\u2009D (p\u2009&lt;\u20090.0001). No\u2009IOL rotations were required. Spectacle independence was achieved in 13 patients (20.64%), while 50 (79.36%) required reading glasses. Among those targeted for bilateral emmetropia, 35 (87.5%) of 40 needed reading spectacles, compared with 15 (65%) of 23 patients with a mini-monovision refractive targe (p\u2009=\u20090.048). No disturbing dysphotopsias such as halos or glare were reported.<\/jats:p>\n                  <jats:p>Conclusion The Tecnis Eyhance Toric IOL demonstrated favourable outcomes for distance and intermediate vision, reliable astigmatism correction, and high patient satisfaction.<\/jats:p>","DOI":"10.1055\/a-2778-8543","type":"journal-article","created":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T00:17:54Z","timestamp":1770855474000},"page":"330-334","source":"Crossref","is-referenced-by-count":0,"title":["Clinical Outcomes after Implantation of the Toric Tecnis Eyhance Intraocular Lens: a Retrospective Analysis"],"prefix":"10.1055","volume":"243","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-6293-7366","authenticated-orcid":false,"given":"Rafael","family":"Lucena","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Pallas Kliniken AG, Olten, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6907-1112","authenticated-orcid":false,"given":"Christoph","family":"Tappeiner","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Pallas Kliniken AG, Olten, Switzerland"},{"name":"Department of Ophthalmology, University Hospital Essen, University Duisburg-Essen, Essen, Germany"},{"name":"Medical Faculty, University of Bern, Bern, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marco","family":"Langenegger","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Pallas Kliniken AG, Olten, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2119-1710","authenticated-orcid":false,"given":"David","family":"Goldblum","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Pallas Kliniken AG, Olten, Switzerland"},{"name":"Medical Faculty, University of Basel, Basel, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tamer","family":"Tandogan","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Pallas Kliniken AG, Olten, Switzerland"},{"name":"Department of Ophthalmology, University Hospital, Heidelberg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2026,2,11]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"e888","DOI":"10.1016\/S2214-109X(17)30293-0","article-title":"Magnitude, temporal trends, and projections of the global prevalence of blindness and distance and near vision impairment: a systematic review and meta-analysis","volume":"5","author":"R Bourne","year":"2017","journal-title":"Lancet Glob Health"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"1140533","DOI":"10.3389\/fpubh.2023.1140533","article-title":"Time trends and heterogeneity in the disease burden of visual impairment due to cataract, 1990\u20132019: A global analysis","volume":"11","author":"X Han","year":"2023","journal-title":"Front Public Health"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1097\/j.jcrs.0000000000001209","article-title":"Two point four million cataract surgeries: 30 years with the Swedish National Cataract Register, 1992\u20132021","volume":"49","author":"T Bro","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"P1","DOI":"10.1016\/j.ophtha.2021.10.006","article-title":"Cataract in the Adult Eye Preferred Practice Pattern","volume":"129","author":"K M Miller","year":"2022","journal-title":"Ophthalmology"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.survophthal.2019.02.012","article-title":"Multifocal versus monofocal intraocular lenses for age-related cataract patients: a system review and meta-analysis based on randomized controlled trials","volume":"64","author":"K Cao","year":"2019","journal-title":"Surv Ophthalmol"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"6699","DOI":"10.1038\/s41598-021-86222-1","article-title":"Comparison of trifocal or hybrid multifocal-extended depth of focus intraocular lenses: a systematic review and meta-analysis","volume":"11","author":"Y Zhong","year":"2021","journal-title":"Sci Rep"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.ajo.2023.01.024","article-title":"Extended Depth of Focus Versus Trifocal for Intraocular Lens Implantation: An Updated Systematic Review and Meta-Analysis","volume":"251","author":"M Karam","year":"2023","journal-title":"Am J Ophthalmol"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1097\/j.jcrs.0000000000001123","article-title":"Vision and patient-reported outcomes with nondiffractive EDOF or neutral aspheric monofocal intraocular lenses","volume":"49","author":"S M Pantanelli","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"902","DOI":"10.1097\/j.jcrs.0000000000000215","article-title":"Surface profiles of new-generation IOLs with improved intermediate vision","volume":"46","author":"D Tognetto","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"520","DOI":"10.3928\/1081597X-20200612-01","article-title":"Enhancing the Intermediate Vision of Monofocal Intraocular Lenses Using a Higher Order Aspheric Optic","volume":"36","author":"A Alarcon","year":"2020","journal-title":"J Refract Surg"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"1202","DOI":"10.1016\/j.ophtha.2025.06.011","article-title":"Comparison of Surgical Methods for the Correction of Low Amounts of Corneal Astigmatism during Cataract Surgery","volume":"132","author":"S C Schallhorn","year":"2025","journal-title":"Ophthalmology"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.2147\/OPTH.S456332","article-title":"Comparative Analysis of Clinical and Patient-Reported Outcomes of a New Enhanced Monofocal IOL and a Conventional Monofocal IOL","volume":"18","author":"S J Dell","year":"2024","journal-title":"Clin Ophthalmol"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"3693","DOI":"10.2147\/OPTH.S442752","article-title":"Comparing Visual Performance and Subjective Outcomes with an Enhanced Monofocal Intraocular Lens When Targeted for Emmetropia or Monovision","volume":"17","author":"H P Sandoval","year":"2023","journal-title":"Clin Ophthalmol"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"5831","DOI":"10.3390\/jcm14165831","article-title":"Long-Term Effectiveness of a Monofocal Intraocular Lens (IOL) Enhanced for Intermediate Vision: A 5-Year Follow-Up Study","volume":"14","author":"R Mencucci","year":"2025","journal-title":"J Clin Med"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1097\/j.jcrs.0000000000001158","article-title":"Rotational stability of a new toric intraocular lens with an advanced optical profile","volume":"49","author":"J Zeilinger","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1097\/j.jcrs.0000000000000399","article-title":"Clinical evaluation of a new monofocal IOL with enhanced intermediate function in patients with cataract","volume":"47","author":"G U Auffarth","year":"2021","journal-title":"J Cataract Refract Surg"}],"container-title":["Klinische Monatsbl\u00e4tter f\u00fcr Augenheilkunde"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2778-8543.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T22:35:33Z","timestamp":1776724533000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2778-8543"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,11]]},"references-count":16,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2026,4,20]]},"published-print":{"date-parts":[[2026,4]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2778-8543","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0023-2165","1439-3999"],"issn-type":[{"value":"0023-2165","type":"print"},{"value":"1439-3999","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,11]]}}}