{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T00:52:56Z","timestamp":1773708776086,"version":"3.50.1"},"reference-count":31,"publisher":"Georg Thieme Verlag KG","issue":"01","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Handchir Mikrochir Plast Chir"],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title>\n                  <jats:p>Schmerzen und Bewegungseinschr\u00e4nkungen der Fingergrundgelenke f\u00fchren zu einem erheblichen Funktionsverlust des betroffenen Fingers sowie der gesamten Hand. Besonders relevant ist dies bei rheumatisch bedingten Gelenkdestruktionen, aber auch bei den selteneren Arthrosen der Fingergrundgelenke. Zur Wiederherstellung der Gelenkfunktion wurden zahlreiche Endoprothesen aus unterschiedlichen Materialien entwickelt, um einen alloplastischen Ersatz dieser Gelenke zu erm\u00f6glichen. Aufgrund vieler Komplikationen ist der gr\u00f6\u00dfte Teil dieser Prothesen schnell wieder vom Markt genommen worden.<\/jats:p>\n                  <jats:p>Langfristig hat sich das Silikonimplantat in den verschiedenen Prothesengeometrien als Referenzstandard f\u00fcr den Gelenkersatz am Fingergrundgelenk etabliert. Die Weiterentwicklung neuer Endoprothesen sollte daher das Ziel verfolgen, eine l\u00e4ngere Haltbarkeit bei gleichzeitig verbesserter Funktionalit\u00e4t zu erreichen. Ma\u00dfgeblicher Vergleichsma\u00dfstab bleiben dabei die mit dem Silikonimplantat erzielbaren Ergebnisse, mit in der Regel guter Prothesenfunktionen und meist sehr guter Schmerzreduktion. F\u00fcr den Erfolg der Fingergrundgelenkendoprothetik sind eine pr\u00e4zise operative Technik sowie eine intensive, individuell angepasste Nachbehandlung von entscheidender Bedeutung.<\/jats:p>","DOI":"10.1055\/a-2799-4534","type":"journal-article","created":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T23:30:24Z","timestamp":1773703824000},"page":"36-47","source":"Crossref","is-referenced-by-count":0,"title":["Stellenwert der Endoprothetik am Fingergrundgelenk"],"prefix":"10.1055","volume":"58","author":[{"given":"Martin","family":"Lautenbach","sequence":"additional","affiliation":[{"name":"Abteilung Handchirurgie, obere Extremit\u00e4t und Fu\u00dfchirurgie, Zentrum f\u00fcr Orthop\u00e4die und Unfallchirurgie, Rheumatologie, Rheumaorthop\u00e4die, Krankenhaus Waldfriede Berlin, Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arne","family":"Tenbrock","sequence":"additional","affiliation":[{"name":"Abteilung Handchirurgie, obere Extremit\u00e4t und Fu\u00dfchirurgie, Zentrum f\u00fcr Orthop\u00e4die und Unfallchirurgie, Rheumatologie, Rheumaorthop\u00e4die, Krankenhaus Waldfriede Berlin, Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2026,3,16]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1177\/028418517701800415","article-title":"Radiographic evaluation of rheumatoid arthritis and related conditions by standard reference films","volume":"18","author":"A Larsen","year":"1977","journal-title":"Acta Radiol Diagn (Stockh)"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"206","DOI":"10.2106\/00004623-198668020-00005","article-title":"Silicone-rubber implant arthroplasty of the metacarpophalangeal joints for rheumatoid arthritis","volume":"68","author":"E J Bieber","year":"1986","journal-title":"J Bone Joint Surg Am"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"1292","DOI":"10.1002\/acr.21705","article-title":"Long-Term followup for rheumatoid arthritis patients in a multicenter outcomes study of silicon metacarpophalangeal joint arthroplasty","volume":"64","author":"K C Chung","year":"2012","journal-title":"Arthritis Care Res (Hoboken)"},{"key":"ref4","first-page":"1395","article-title":"Patient outcomes following Swanson silastic metacarpophalangeal joint arthroplasty in the rheumatoid hand: a systematic overview","volume":"27","author":"K C Chung","year":"2000","journal-title":"J Rheumatol"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1055\/s-2007-965229","article-title":"Die vaskularisierte Gelenktransplantation zum Fingergelenkersatz","volume":"39","author":"R Hierner","year":"2007","journal-title":"Handchir Mikrochir Plast Chir"},{"key":"ref6","first-page":"105","volume-title":"Arthroplasties des m\u00e9tacarpophalangeiennes dans la main rheumatoide. In:","author":"D V Egloff","year":"1996"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1055\/s-2002-33689","article-title":"Die Denervierung von Fingergelenken als Alternative zur Arthrodese und Endoprothese","volume":"34","author":"R Mark","year":"2002","journal-title":"Handchir Mikrochir Plast Chir"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.jhsa.2009.09.020","article-title":"NeuFlex and Swanson metacarpophalangeal implants for rheumatoid arthritis: prospective randomized, controlled clinical trial","volume":"35","author":"B G Escott","year":"2010","journal-title":"J Hand Surg Am"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/S0363-5023(05)80104-2","article-title":"Swanson silicone finger joint implants: a review of the literature regarding long-term complications","volume":"20","author":"D E Foliart","year":"1995","journal-title":"J Hand Surg Am"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1055\/a-1759-3416","article-title":"Differentialtherapeutische Zug\u00e4nge bei der prothetischen Versorgung von Fingergelenken","volume":"54","author":"R Lab\u00e8r","year":"2022","journal-title":"Handchir Mikrochir Plast Chir"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1055\/a-1348-9094","article-title":"Endoprothetik der Fingergrundgelenke. Teil 1: Grundlagen und Indikationen","volume":"12","author":"M Lautenbach","year":"2023","journal-title":"Handchirurgie Scan"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1055\/a-2021-4158","article-title":"Endoprothetik der Fingergrundgelenke. Teil 2: Operationstechnik, Nachbehandlung und Ergebnisse","volume":"12","author":"M Lautenbach","year":"2023","journal-title":"Handchirurgie Scan"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/S0266-7681(05)80038-5","article-title":"Metacarpophalangeal joint prostheses: a review of the clinical results of past and current designs","volume":"20","author":"D M Lichtman","year":"1995","journal-title":"J Hand Surg Br"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"635","DOI":"10.2106\/00004623-199905000-00005","article-title":"Long-term follow-up of pyrolytic carbon metacarpophalangeal Implants","volume":"82","author":"S D Cook","year":"1999","journal-title":"J Bone Joint Surg Am"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"1956","DOI":"10.1016\/j.jhsa.2015.06.104","article-title":"Pyrocarbon metakarpophalangeal joint arthroplasty in noninflammatory arthritis: Minimum 5-year follow-up","volume":"40","author":"D R Dickson","year":"2015","journal-title":"J Hand Surg Am"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1177\/1558944720926631.","article-title":"Long-term Outcomes of MCP Surface Replacement Arthroplasty in Patients With Rheumatoid Arthritis","volume":"17","author":"M R Claxton","year":"2022","journal-title":"Hand (NY)"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.jhsa.2005.10.002","article-title":"Osseointegration and mechanical stability of pyrocarbon and titanium hand implants in a load-bearing in vivo model for small joint arthroplasty","volume":"31","author":"W Daecke","year":"2006","journal-title":"J Hand Surg Am"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1007\/s00132-019-03716-7","article-title":"Anatomie des Fingergrund- und mittelgelenks unter Ber\u00fccksichtigung der Endoprothetik","volume":"48","author":"B Hohendorff","year":"2019","journal-title":"Orthop\u00e4de"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1016\/j.jhsa.2007.09.005","article-title":"Preliminary results of nonconstrained pyrolytic carbon arthroplasty for metacarpophalangeal joint arthritis","volume":"32","author":"W L Parker","year":"2007","journal-title":"J Hand Surg Am"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"435","DOI":"10.2106\/00004623-197254030-00001","article-title":"Flexible implant arthroplasty of arthritic finger joints. Rationale, technique and results of treatment","volume":"54","author":"A B Swanson","year":"1972","journal-title":"J Bone Joint Surg Am"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1007\/s11552-012-9401-9","article-title":"Metallosis following silicone metacarpophalangeal joint arthroplasties with grommets: case report","volume":"7","author":"I K Choudhry","year":"2012","journal-title":"Hand (N Y)"},{"key":"ref22","volume-title":"Hand Arthroplasties","author":"B R Simmen","year":"2000"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"796","DOI":"10.1016\/j.jhsa.2004.04.023","article-title":"Metacarpophalangeal joint mechanics after 3 different silicone arthroplasties","volume":"30","author":"A P Weiss","year":"2004","journal-title":"J Hand Surg Am"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1055\/a-1024-7368","article-title":"Endoprothetik der Fingermittelgelenke","volume":"09","author":"S Schindele","year":"2020","journal-title":"Handchirurgie Scan"},{"key":"ref25","doi-asserted-by":"crossref","first-page":"289.e1","DOI":"10.1016\/j.jhsa.2017.10.001","article-title":"Outcomes following acute metacarpophalangeal joint arthroplasty dislocation: An analysis of 37 cases","volume":"43","author":"N Wanderman","year":"2018","journal-title":"J Hand Surg Am"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1302\/0301-620X.51B4.664","article-title":"The influence of wrist position on finger deviation in the rheumatoid hand","volume":"51","author":"J A Pahle","year":"1969","journal-title":"J Bone Joint Surg Am"},{"key":"ref27","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.jhsa.2017.10.010","article-title":"Silicone metacarpophalangeal arthroplasty for osteoarthritis: Long-term results","volume":"43","author":"N T Morrell","year":"2018","journal-title":"J Hand Surg Am"},{"key":"ref28","doi-asserted-by":"crossref","first-page":"2416","DOI":"10.1016\/j.jhsa.2015.09.012","article-title":"Metacarpophalangeal joint arthroplasty in the setting of trauma","volume":"40","author":"M T Houdek","year":"2015","journal-title":"J Hand Surg Am"},{"key":"ref29","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/S0749-0712(21)00813-1","article-title":"Treatment considerations in the complicated rheumatoid hand","volume":"5","author":"A Miller-Breslow","year":"1989","journal-title":"Hand Clin"},{"key":"ref30","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/j.jhsa.2004.08.013","article-title":"Use of volar plate for reconstructing the radial collateral ligament after metacarpophalangeal arthroplasty of fingers in rheumatoid arthritis: surgical technique","volume":"30","author":"H E Kleinert","year":"2005","journal-title":"J Hand Surg Am"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1080\/02844319950159163","article-title":"Ten-year follow up silicone arthroplasty of the metacarpophalangeal joints in rheumatoid hands","volume":"33","author":"K Schmidt","year":"1999","journal-title":"Scand J Plast Reconstr Hand Surg"}],"container-title":["Handchirurgie \u00b7 Mikrochirurgie \u00b7 Plastische Chirurgie"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2799-4534.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T23:30:56Z","timestamp":1773703856000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2799-4534"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3]]},"references-count":31,"journal-issue":{"issue":"01","published-online":{"date-parts":[[2026,3,16]]},"published-print":{"date-parts":[[2026,3]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2799-4534","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0722-1819","1439-3980"],"issn-type":[{"value":"0722-1819","type":"print"},{"value":"1439-3980","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3]]}}}