{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T23:05:37Z","timestamp":1779491137044,"version":"3.53.1"},"reference-count":37,"publisher":"Georg Thieme Verlag KG","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Semin Musculoskelet Radiol"],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Spine magnetic resonance imaging is among the most frequently performed examinations in clinical radiology and places substantial demands on workflow efficiency and image quality. Over the past 20 years, acquisition times have been markedly reduced through a combination of optimized sequence parameters, advanced acceleration techniques, and modern image reconstruction methods.<\/jats:p>\n                  <jats:p>This article provides an overview of contemporary strategies for accelerating two-dimensional spine magnetic resonance imaging, with a focus on techniques that are robust and feasible in routine clinical practice. Classical parameter optimization, parallel imaging, compressed sensing, simultaneous multislice acquisition, and image reconstruction based on artificial intelligence are discussed with regard to their technical principles, advantages, and limitations.<\/jats:p>\n                  <jats:p>Particular emphasis is placed on practical protocol integration and a \u201chow we do it\u201d approach, illustrating how these methods can be combined to achieve substantial time savings while preserving diagnostic confidence. When applied judiciously, modern acceleration and reconstruction techniques enable efficient, high-quality spine magnetic resonance imaging and are particularly well suited for this high-volume clinical application.<\/jats:p>","DOI":"10.1055\/a-2800-8484","type":"journal-article","created":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T00:24:39Z","timestamp":1773102279000},"page":"339-349","source":"Crossref","is-referenced-by-count":0,"title":["Accelerated Spine Magnetic Resonance Imaging: Techniques and Practical Implementation for Routine Clinical Imaging"],"prefix":"10.1055","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8733-131X","authenticated-orcid":false,"given":"Benjamin","family":"Fritz","sequence":"additional","affiliation":[{"name":"Department of Radiology, Balgrist University Hospital, Zurich, Switzerland"},{"name":"Faculty of Medicine, University of Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2026,3,9]]},"reference":[{"issue":"22","key":"ref1","doi-asserted-by":"crossref","first-page":"2400","DOI":"10.1001\/jama.2012.5960","article-title":"Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996-2010","volume":"307","author":"R Smith-Bindman","year":"2012","journal-title":"JAMA"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"S361","DOI":"10.1016\/j.jacr.2021.08.002","article-title":"ACR Appropriateness Criteria\u00ae Low Back Pain: 2021 Update","volume":"18","author":"T A Hutchins","year":"2021","journal-title":"J Am Coll Radiol"},{"issue":"02","key":"ref3","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1007\/s00586-016-4724-9","article-title":"Radiographic assessment of degenerative lumbar spinal stenosis: is MRI superior to CT?","volume":"26","author":"K Alsaleh","year":"2017","journal-title":"Eur Spine J"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1186\/s12891-016-1169-6","article-title":"Role of magnetic resonance imaging in acute spinal trauma: a pictorial review","volume":"17","author":"Y Kumar","year":"2016","journal-title":"BMC Musculoskelet Disord"},{"issue":"08","key":"ref5","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1007\/s003300050276","article-title":"Fast spin echo vs conventional spin echo in cervical spine imaging","volume":"7","author":"A R Gillams","year":"1997","journal-title":"Eur Radiol"},{"issue":"02","key":"ref6","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1148\/radiology.180.2.2068326","article-title":"T2-weighted spin-echo pulse sequence with variable repetition and echo times for reduction of MR image acquisition time","volume":"180","author":"R K Butts","year":"1991","journal-title":"Radiology"},{"issue":"03","key":"ref7","doi-asserted-by":"crossref","first-page":"704","DOI":"10.2214\/AJR.20.22901","article-title":"Rapid musculoskeletal MRI in 2021: value and optimized use of widely accessible techniques","volume":"216","author":"F Del Grande","year":"2021","journal-title":"AJR Am J Roentgenol"},{"issue":"03","key":"ref8","doi-asserted-by":"crossref","first-page":"718","DOI":"10.2214\/AJR.20.22902","article-title":"Rapid musculoskeletal MRI in 2021: clinical application of advanced accelerated techniques","volume":"216","author":"J Fritz","year":"2021","journal-title":"AJR Am J Roentgenol"},{"issue":"05","key":"ref9","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","article-title":"SENSE: sensitivity encoding for fast MRI","volume":"42","author":"K P Pruessmann","year":"1999","journal-title":"Magn Reson Med"},{"issue":"06","key":"ref10","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1002\/mrm.10171","article-title":"Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)","volume":"47","author":"M A Griswold","year":"2002","journal-title":"Magn Reson Med"},{"issue":"01","key":"ref11","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1002\/mrm.27355","article-title":"Assessment of the generalization of learned image reconstruction and the potential for transfer learning","volume":"81","author":"F Knoll","year":"2019","journal-title":"Magn Reson Med"},{"issue":"06","key":"ref12","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1002\/mrm.1910030602","article-title":"RARE imaging: a fast imaging method for clinical MR","volume":"3","author":"J Hennig","year":"1986","journal-title":"Magn Reson Med"},{"issue":"01","key":"ref13","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1002\/mrm.1910140112","article-title":"Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging","volume":"14","author":"F Farzaneh","year":"1990","journal-title":"Magn Reson Med"},{"issue":"02","key":"ref14","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/0730-725X(88)90444-4","article-title":"Correction of spatially dependent phase shifts for partial Fourier imaging","volume":"6","author":"J R MacFall","year":"1988","journal-title":"Magn Reson Imaging"},{"issue":"01","key":"ref15","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1002\/mrm.1910300109","article-title":"Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI","volume":"30","author":"G McGibney","year":"1993","journal-title":"Magn Reson Med"},{"issue":"S 01","key":"ref17","doi-asserted-by":"crossref","first-page":"S81","DOI":"10.1093\/pm\/pnac130","article-title":"Magnetic resonance imaging of the lumbar spine: recommendations for acquisition and image evaluation from the BACPAC Spine Imaging Working Group","volume":"24","author":"N Sollmann","year":"2023","journal-title":"Pain Med"},{"issue":"09","key":"ref18","doi-asserted-by":"crossref","first-page":"1799","DOI":"10.1007\/s00256-024-04634-2","article-title":"Modern acceleration in musculoskeletal MRI: applications, implications, and challenges","volume":"53","author":"J Vosshenrich","year":"2024","journal-title":"Skeletal Radiol"},{"issue":"01","key":"ref19","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1002\/jmri.23639","article-title":"Parallel MR imaging","volume":"36","author":"A Deshmane","year":"2012","journal-title":"J Magn Reson Imaging"},{"issue":"04","key":"ref20","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1097\/01.rmr.0000136558.09801.dd","article-title":"SMASH, SENSE, PILS, GRAPPA: how to choose the optimal method","volume":"15","author":"M Blaimer","year":"2004","journal-title":"Top Magn Reson Imaging"},{"issue":"01","key":"ref21","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1007\/s00256-017-2780-9","article-title":"Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol: a multi-institutional multi-reader study","volume":"47","author":"E F Alaia","year":"2018","journal-title":"Skeletal Radiol"},{"issue":"04","key":"ref22","doi-asserted-by":"crossref","first-page":"W146","DOI":"10.2214\/AJR.16.17041","article-title":"Comparison of a fast 5-minute shoulder MRI protocol with a standard shoulder MRI protocol: a multiinstitutional multireader study","volume":"208","author":"N Subhas","year":"2017","journal-title":"AJR Am J Roentgenol"},{"issue":"02","key":"ref23","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1002\/1522-2586(200102)13:2<313::AID-JMRI1045>3.0.CO;2-W","article-title":"Use of multicoil arrays for separation of signal from multiple slices simultaneously excited","volume":"13","author":"D J Larkman","year":"2001","journal-title":"J Magn Reson Imaging"},{"issue":"01","key":"ref24","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1002\/mrm.25897","article-title":"Simultaneous multislice (SMS) imaging techniques","volume":"75","author":"M Barth","year":"2016","journal-title":"Magn Reson Med"},{"issue":"05","key":"ref25","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1111\/jon.12453","article-title":"Simultaneous multislice-based 5-minute lumbar spine MRI protocol: initial experience in a clinical setting","volume":"27","author":"M G Longo","year":"2017","journal-title":"J Neuroimaging"},{"issue":"09","key":"ref26","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1097\/RLI.0000000000000376","article-title":"Simultaneous multislice accelerated turbo spin echo magnetic resonance imaging: comparison and combination with in-plane parallel imaging acceleration for high-resolution magnetic resonance imaging of the knee","volume":"52","author":"J Fritz","year":"2017","journal-title":"Invest Radiol"},{"issue":"01","key":"ref27","doi-asserted-by":"crossref","first-page":"e241249","DOI":"10.1148\/radiol.241249","article-title":"Deep learning superresolution for simultaneous multislice parallel imaging-accelerated knee MRI using arthroscopy validation","volume":"314","author":"S S Walter","year":"2025","journal-title":"Radiology"},{"issue":"06","key":"ref28","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1002\/mrm.21391","article-title":"Sparse MRI: the application of compressed sensing for rapid MR imaging","volume":"58","author":"M Lustig","year":"2007","journal-title":"Magn Reson Med"},{"issue":"04","key":"ref29","doi-asserted-by":"crossref","first-page":"966","DOI":"10.1002\/jmri.25547","article-title":"Compressed sensing for body MRI","volume":"45","author":"L Feng","year":"2017","journal-title":"J Magn Reson Imaging"},{"issue":"03","key":"ref30","doi-asserted-by":"crossref","first-page":"254","DOI":"10.2463\/mrms.tn.2019-0095","article-title":"Compressed sensing MR imaging (CS-MRI) of the knee: assessment of quality, inter-reader agreement, and acquisition time","volume":"19","author":"G R Matcuk","year":"2020","journal-title":"Magn Reson Med Sci"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.ejrad.2019.06.006","article-title":"Accelerating anatomical 2D turbo spin echo imaging of the ankle using compressed sensing","volume":"118","author":"A S Gersing","year":"2019","journal-title":"Eur J Radiol"},{"issue":"09","key":"ref32","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1097\/RLI.0b013e31828a012d","article-title":"Clinical image quality assessment of accelerated magnetic resonance neuroimaging using compressed sensing","volume":"48","author":"S D Sharma","year":"2013","journal-title":"Invest Radiol"},{"issue":"21","key":"ref33","doi-asserted-by":"crossref","first-page":"9802","DOI":"10.3390\/app11219802","article-title":"Artifact reduction in compressed sensing averaging techniques for high-resolution magnetic resonance images","volume":"11","author":"J-M Shim","year":"2021","journal-title":"Appl Sci (Basel)"},{"issue":"01","key":"ref34","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1055\/s-0039-3400265","article-title":"Improving the speed of MRI with artificial intelligence","volume":"24","author":"P M Johnson","year":"2020","journal-title":"Semin Musculoskelet Radiol"},{"issue":"06","key":"ref35","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.2214\/AJR.20.23313","article-title":"Using deep learning to accelerate knee MRI at 3 T: results of an interchangeability study","volume":"215","author":"M P Recht","year":"2020","journal-title":"AJR Am J Roentgenol"},{"issue":"03","key":"ref36","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1007\/s11547-024-01787-x","article-title":"Deep learning-accelerated image reconstruction in back pain-MRI imaging: reduction of acquisition time and improvement of image quality","volume":"129","author":"A Estler","year":"2024","journal-title":"Radiol Med"},{"issue":"01","key":"ref37","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/RLI.0000000000000928","article-title":"Artificial intelligence-driven ultra-fast superresolution MRI: 10-fold accelerated musculoskeletal turbo spin echo MRI within reach","volume":"58","author":"D J Lin","year":"2023","journal-title":"Invest Radiol"},{"issue":"12","key":"ref38","doi-asserted-by":"crossref","first-page":"e70178","DOI":"10.1002\/mp.70178","article-title":"An end-to-end deep learning method for reconstructing SMS-PI accelerated musculoskeletal MRI","volume":"52","author":"M Mostapha","year":"2025","journal-title":"Med Phys"}],"container-title":["Seminars in Musculoskeletal Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2800-8484.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T22:32:43Z","timestamp":1779489163000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2800-8484"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,9]]},"references-count":37,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2026,5,22]]},"published-print":{"date-parts":[[2026,6]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2800-8484","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["1089-7860","1098-898X"],"issn-type":[{"value":"1089-7860","type":"print"},{"value":"1098-898X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,9]]}}}