{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T23:04:12Z","timestamp":1784588652602,"version":"3.55.0"},"reference-count":128,"publisher":"Georg Thieme Verlag KG","issue":"04","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Semin Musculoskelet Radiol"],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Computed tomography remains essential in musculoskeletal imaging, offering superior spatial resolution and contrast for detailed assessment of bone anatomy and fractures, as well as for evaluation in the pre- and postoperative settings. Decades of technological progress\u2014from helical to advanced high-resolution, dose-efficient systems\u2014have reinforced the central role of computed tomography in bone imaging.<\/jats:p>\n                  <jats:p>Expanding beyond static skeletal assessment, spectral computed tomography enables characterization of crystal deposits, marrow edema, and metal artifact reduction; weight-bearing cone-beam computed tomography assesses joint alignment; computed tomography arthrography offers a radiation-based alternative to magnetic resonance imaging to assess internal joint disorders; and dynamic computed tomography provides insight into joint motion.<\/jats:p>\n                  <jats:p>Emerging technologies such as photon-counting computed tomography promise unprecedented spatial and spectral performance with reduced dose. Synthetic computed tomography derived from magnetic resonance imaging data integrates osseous detail without radiation exposure.<\/jats:p>\n                  <jats:p>This 30-year perspective reviews major technological advances, highlights current clinical applications, and explores future directions shaping the role of computed tomography in musculoskeletal imaging.<\/jats:p>","DOI":"10.1055\/a-2826-6432","type":"journal-article","created":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T22:35:41Z","timestamp":1780612541000},"page":"397-413","source":"Crossref","is-referenced-by-count":0,"title":["Musculoskeletal Computed Tomography Imaging: A 30-Year Perspective"],"prefix":"10.1055","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3251-3666","authenticated-orcid":false,"given":"Patrick","family":"Omoumi","sequence":"additional","affiliation":[{"name":"Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maxime","family":"Pastor","sequence":"additional","affiliation":[{"name":"Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shadpour","family":"Demehri","sequence":"additional","affiliation":[{"name":"Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed","family":"Jarraya","sequence":"additional","affiliation":[{"name":"Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edwin","family":"Oei","sequence":"additional","affiliation":[{"name":"Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro","family":"Teixeira","sequence":"additional","affiliation":[{"name":"Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruno","family":"Vande Berg","sequence":"additional","affiliation":[{"name":"Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joel","family":"Greffier","sequence":"additional","affiliation":[{"name":"Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2026,6,4]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"S16","DOI":"10.1002\/jmrs.811","article-title":"Demonstrating the use of population level data to investigate trends in the rate, radiation dose and cost of computed tomography across clinical groups: are there any areas of concern?","volume":"72","author":"S Kamarova","year":"2025","journal-title":"J Med Radiat Sci"},{"issue":"02","key":"ref2","doi-asserted-by":"crossref","first-page":"e230344","DOI":"10.1148\/radiol.230344","article-title":"Musculoskeletal CT imaging: state-of-the-art advancements and future directions","volume":"308","author":"S Demehri","year":"2023","journal-title":"Radiology"},{"issue":"11","key":"ref3","doi-asserted-by":"crossref","first-page":"1742","DOI":"10.2967\/jnumed.117.205567","article-title":"Cost-effectiveness of bone SPECT\/CT in painful total knee arthroplasty","volume":"59","author":"T Van den Wyngaert","year":"2018","journal-title":"J Nucl Med"},{"issue":"04","key":"ref4","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1016\/j.arth.2014.11.019","article-title":"Clinical usefulness of SPECT-CT in patients with an unexplained pain in metal on metal (MOM) total hip arthroplasty","volume":"30","author":"R Berber","year":"2015","journal-title":"J Arthroplasty"},{"issue":"01","key":"ref5","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.fas.2011.01.009","article-title":"SPECT-CT imaging of obscure foot and ankle pain","volume":"18","author":"T Williams","year":"2012","journal-title":"Foot Ankle Surg"},{"issue":"04","key":"ref6","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1177\/1947603519855776","article-title":"The value of SPECT\/CT for knee osteoarthritis: a systematic review","volume":"12","author":"D Zarringam","year":"2021","journal-title":"Cartilage"},{"issue":"01","key":"ref7","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1148\/radiol.2020192498","article-title":"State of the art: imaging of osteoarthritis\u2014revisited 2020","volume":"296","author":"F W Roemer","year":"2020","journal-title":"Radiology"},{"issue":"04","key":"ref8","first-page":"e25","article-title":"Rating the efficacy of diagnostic imaging studies conducted for the workup of musculoskeletal tumors","volume":"9","author":"W T Li","year":"2025","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"issue":"09","key":"ref9","doi-asserted-by":"crossref","first-page":"1889","DOI":"10.1007\/s00256-024-04622-6","article-title":"Chances and challenges of photon-counting CT in musculoskeletal imaging","volume":"53","author":"C Mourad","year":"2024","journal-title":"Skeletal Radiol"},{"key":"ref10","first-page":"S2211","article-title":"A review of current applications of photon-counting CT in musculoskeletal imaging","author":"V Bousson","year":"2026","journal-title":"Diagn Interv Imaging"},{"issue":"04","key":"ref11","doi-asserted-by":"crossref","first-page":"551","DOI":"10.2214\/AJR.22.28418","article-title":"Photon-counting detector CT for musculoskeletal imaging: a clinical perspective","volume":"220","author":"F I Baffour","year":"2023","journal-title":"AJR Am J Roentgenol"},{"issue":"04","key":"ref12","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1055\/s-0043-1768451","article-title":"Computed tomography bone imaging: pushing the boundaries in clinical practice","volume":"27","author":"R Gillet","year":"2023","journal-title":"Semin Musculoskelet Radiol"},{"issue":"06","key":"ref13","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.diii.2024.02.001","article-title":"Ultra-high-resolution CT of the temporal bone: comparison between deep learning reconstruction and hybrid and model-based iterative reconstruction","volume":"105","author":"A Beysang","year":"2024","journal-title":"Diagn Interv Imaging"},{"key":"ref14","first-page":"113171E","article-title":"Application of a novel ultra-high resolution multi-detector CT in quantitative imaging of trabecular microstructure","volume":"11317","author":"G Shi","year":"2020","journal-title":"Proc SPIE Int Soc Opt Eng"},{"issue":"02","key":"ref15","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.diii.2024.09.002","article-title":"Photon-counting CT systems: a technical review of current clinical possibilities","volume":"106","author":"J Greffier","year":"2025","journal-title":"Diagn Interv Imaging"},{"issue":"04","key":"ref16","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.diii.2022.11.003","article-title":"Spectral CT imaging: technical principles of dual-energy CT and multi-energy photon-counting CT","volume":"104","author":"J Greffier","year":"2023","journal-title":"Diagn Interv Imaging"},{"issue":"05","key":"ref17","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1055\/s-0035-1569254","article-title":"Optimization of radiation dose and image quality in musculoskeletal CT: emphasis on iterative reconstruction techniques (Part 2)","volume":"19","author":"P Omoumi","year":"2015","journal-title":"Semin Musculoskelet Radiol"},{"issue":"05","key":"ref18","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1055\/s-0035-1569255","article-title":"Optimization of radiation dose and image quality in musculoskeletal CT: emphasis on iterative reconstruction techniques (Part 1)","volume":"19","author":"P Omoumi","year":"2015","journal-title":"Semin Musculoskelet Radiol"},{"issue":"01","key":"ref19","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.diii.2024.09.004","article-title":"Comparison between artificial intelligence solution and radiologist for the detection of pelvic, hip and extremity fractures on radiographs in adult using CT as standard of reference","volume":"106","author":"M Pastor","year":"2025","journal-title":"Diagn Interv Imaging"},{"issue":"04","key":"ref20","doi-asserted-by":"crossref","first-page":"2621","DOI":"10.1007\/s00330-020-07304-8","article-title":"Ultra-low-dose CT versus radiographs for minor spine and pelvis trauma: a Bayesian analysis of accuracy","volume":"31","author":"A Hamard","year":"2021","journal-title":"Eur Radiol"},{"issue":"08","key":"ref21","doi-asserted-by":"crossref","first-page":"4248","DOI":"10.21037\/qims-21-848","article-title":"Early results of ultra-low-dose CT-scan for extremity traumas in emergency room","volume":"12","author":"T E Addala","year":"2022","journal-title":"Quant Imaging Med Surg"},{"issue":"02","key":"ref22","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.diii.2019.01.007","article-title":"Low and ultra-low dose radiation in CT: opportunities and limitations","volume":"100","author":"J P Beregi","year":"2019","journal-title":"Diagn Interv Imaging"},{"issue":"02","key":"ref23","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1007\/s00330-019-06425-z","article-title":"Optimization of radiation dose for CT detection of lytic and sclerotic bone lesions: a phantom study","volume":"30","author":"J Greffier","year":"2020","journal-title":"Eur Radiol"},{"issue":"03","key":"ref24","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1177\/0284185113494981","article-title":"Low-dose multidetector computed tomography of the cervical spine: optimization of iterative reconstruction strength levels","volume":"55","author":"P Omoumi","year":"2014","journal-title":"Acta Radiol"},{"issue":"11","key":"ref25","doi-asserted-by":"crossref","first-page":"1850","DOI":"10.3348\/kjr.2021.0140","article-title":"Deep learning algorithm for simultaneous noise reduction and edge sharpening in low-dose CT images: a pilot study using lumbar spine CT","volume":"22","author":"H Yeoh","year":"2021","journal-title":"Korean J Radiol"},{"issue":"01","key":"ref26","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1007\/s00256-021-03828-2","article-title":"Clinical evaluation of a phantom-based deep convolutional neural network for whole-body-low-dose and ultra-low-dose CT skeletal surveys","volume":"51","author":"N Huber","year":"2022","journal-title":"Skeletal Radiol"},{"issue":"05","key":"ref27","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.diii.2018.12.007","article-title":"Influence of iterative reconstruction and dose levels on metallic artifact reduction: a phantom study within four CT systems","volume":"100","author":"J Greffier","year":"2019","journal-title":"Diagn Interv Imaging"},{"issue":"05","key":"ref28","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1055\/s-0035-1569253","article-title":"Dual-energy CT: basic principles, technical approaches, and applications in musculoskeletal imaging (Part 1)","volume":"19","author":"P Omoumi","year":"2015","journal-title":"Semin Musculoskelet Radiol"},{"issue":"05","key":"ref29","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1055\/s-0035-1569252","article-title":"Dual-energy CT: basic principles, technical approaches, and applications in musculoskeletal imaging (Part 2)","volume":"19","author":"P Omoumi","year":"2015","journal-title":"Semin Musculoskelet Radiol"},{"key":"ref30","first-page":"124","article-title":"Gout, yesterday and today","volume":"44","author":"J Malghem","year":"2004","journal-title":"Feuillets de Radiologie"},{"issue":"08","key":"ref31","doi-asserted-by":"crossref","first-page":"1406","DOI":"10.1002\/art.1780390820","article-title":"Computed tomography of the knee joint as an indicator of intraarticular tophi in gout","volume":"39","author":"J C Gerster","year":"1996","journal-title":"Arthritis Rheum"},{"issue":"01","key":"ref32","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1136\/ard.61.1.52","article-title":"Imaging of tophaceous gout: computed tomography provides specific images compared with magnetic resonance imaging and ultrasonography","volume":"61","author":"J C Gerster","year":"2002","journal-title":"Ann Rheum Dis"},{"issue":"04","key":"ref33","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/j.rdc.2016.07.005","article-title":"Imaging in gout and other crystal-related arthropathies","volume":"42","author":"P Omoumi","year":"2016","journal-title":"Rheum Dis Clin North Am"},{"issue":"06","key":"ref34","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1136\/annrheumdis-2013-205095","article-title":"Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study","volume":"74","author":"T Bongartz","year":"2015","journal-title":"Ann Rheum Dis"},{"issue":"09","key":"ref35","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1111\/1756-185X.12874","article-title":"Dual energy computed tomography: a novel technique for diagnosis of gout","volume":"19","author":"Z Ahmad","year":"2016","journal-title":"Int J Rheum Dis"},{"issue":"02","key":"ref36","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1148\/radiol.11102485","article-title":"Identification of intraarticular and periarticular uric acid crystals with dual-energy CT: initial evaluation","volume":"261","author":"K N Glazebrook","year":"2011","journal-title":"Radiology"},{"issue":"10","key":"ref37","doi-asserted-by":"crossref","first-page":"4861","DOI":"10.1093\/rheumatology\/keaa923","article-title":"Dual-energy computed tomography vs ultrasound, alone or combined, for the diagnosis of gout: a prospective study of accuracy","volume":"60","author":"J A Singh","year":"2021","journal-title":"Rheumatology (Oxford)"},{"issue":"10","key":"ref38","doi-asserted-by":"crossref","first-page":"2557","DOI":"10.1002\/art.39254","article-title":"2015 Gout Classification Criteria: an American College of Rheumatology\/European League Against Rheumatism collaborative initiative","volume":"67","author":"T Neogi","year":"2015","journal-title":"Arthritis Rheumatol"},{"issue":"05","key":"ref39","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.2214\/AJR.15.15356","article-title":"Dual-energy CT of urate deposits in costal cartilage and intervertebral disks of patients with tophaceous gout and age-matched controls","volume":"206","author":"A Carr","year":"2016","journal-title":"AJR Am J Roentgenol"},{"issue":"01","key":"ref40","doi-asserted-by":"crossref","first-page":"W103-9","DOI":"10.2214\/AJR.13.11396","article-title":"Artifacts in dual-energy CT gout protocol: a review of 50 suspected cases with an artifact identification guide","volume":"203","author":"P I Mallinson","year":"2014","journal-title":"AJR Am J Roentgenol"},{"issue":"17","key":"ref41","doi-asserted-by":"crossref","first-page":"5249","DOI":"10.3390\/jcm11175249","article-title":"The clinical utility of dual-energy computed tomography in the diagnosis of gout-a cross-sectional study","volume":"11","author":"M Sotniczuk","year":"2022","journal-title":"J Clin Med"},{"issue":"06","key":"ref42","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.2214\/AJR.19.21404","article-title":"Impact of dual-energy CT postprocessing protocol for the detection of gouty arthritis and quantification of tophi in patients presenting with podagra: comparison with ultrasound","volume":"213","author":"S Strobl","year":"2019","journal-title":"AJR Am J Roentgenol"},{"issue":"09","key":"ref43","doi-asserted-by":"crossref","first-page":"1309","DOI":"10.1016\/j.joca.2019.05.007","article-title":"Dual-energy computed tomography in calcium pyrophosphate deposition: initial clinical experience","volume":"27","author":"T Pascart","year":"2019","journal-title":"Osteoarthritis Cartilage"},{"issue":"07","key":"ref44","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1097\/RLI.0000000000000756","article-title":"Dual-energy computed tomography for detection and characterization of monosodium urate, calcium pyrophosphate, and hydroxyapatite: a phantom study on diagnostic performance","volume":"56","author":"A D\u00f8ssing","year":"2021","journal-title":"Invest Radiol"},{"issue":"01","key":"ref45","doi-asserted-by":"crossref","first-page":"100436","DOI":"10.1016\/j.ocarto.2024.100436","article-title":"Dual energy computed tomography cannot effectively differentiate between calcium pyrophosphate and basic calcium phosphate diseases in the clinical setting","volume":"6","author":"M Jarraya","year":"2024","journal-title":"Osteoarthr Cartil Open"},{"issue":"01","key":"ref46","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.crad.2020.08.006","article-title":"Dual-energy CT in musculoskeletal trauma","volume":"76","author":"A JN Wong","year":"2021","journal-title":"Clin Radiol"},{"key":"ref47","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.ejrad.2016.12.008","article-title":"Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures: a prospective feasibility study on a single- source volume CT scanner","volume":"87","author":"T Diekhoff","year":"2017","journal-title":"Eur J Radiol"},{"issue":"01","key":"ref48","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1148\/radiol.2021203624","article-title":"DECT in detection of vertebral fracture-associated bone marrow edema: a systematic review and meta-analysis with emphasis on technical and imaging interpretation parameters","volume":"300","author":"F Ghazi Sherbaf","year":"2021","journal-title":"Radiology"},{"issue":"10","key":"ref49","doi-asserted-by":"crossref","first-page":"2977","DOI":"10.1007\/s00234-025-03763-2","article-title":"Diagnostic accuracy of dual-energy CT in detecting traumatic vertebral bone marrow edema: a prospective comparative study with MRI in the context of a level I trauma center","volume":"67","author":"T Beyer","year":"2025","journal-title":"Neuroradiology"},{"issue":"01","key":"ref50","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1007\/s10140-014-1249-6","article-title":"Detection of occult, undisplaced hip fractures with a dual-energy CT algorithm targeted to detection of bone marrow edema","volume":"22","author":"T Reddy","year":"2015","journal-title":"Emerg Radiol"},{"issue":"03","key":"ref51","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1148\/radiol.2017161063","article-title":"Detection of bone marrow edema in nondisplaced hip fractures: utility of a virtual noncalcium dual-energy CT application","volume":"284","author":"T T Kellock","year":"2017","journal-title":"Radiology"},{"issue":"02","key":"ref52","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1148\/radiol.10091230","article-title":"Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions\u2014feasibility study","volume":"256","author":"G Pache","year":"2010","journal-title":"Radiology"},{"issue":"03","key":"ref53","doi-asserted-by":"crossref","first-page":"493","DOI":"10.2214\/AJR.19.21095","article-title":"Dual-energy CT in musculoskeletal imaging: what is the role beyond gout?","volume":"213","author":"P Rajiah","year":"2019","journal-title":"AJR Am J Roentgenol"},{"issue":"01","key":"ref54","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s00256-020-03528-3","article-title":"Benefits of iterative metal artifact reduction and dual-energy CT towards mitigating artifact in the setting of total shoulder prostheses","volume":"50","author":"P Mohammadinejad","year":"2021","journal-title":"Skeletal Radiol"},{"issue":"02","key":"ref55","doi-asserted-by":"crossref","first-page":"395","DOI":"10.2214\/AJR.18.19757","article-title":"Clinical assessment of metal artifact reduction methods in dual-energy CT examinations of instrumented spines","volume":"212","author":"Z Long","year":"2019","journal-title":"AJR Am J Roentgenol"},{"issue":"08","key":"ref56","doi-asserted-by":"crossref","first-page":"1783","DOI":"10.1007\/s00586-019-05984-5","article-title":"Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation","volume":"28","author":"Y Zeng","year":"2019","journal-title":"Eur Spine J"},{"issue":"05","key":"ref57","doi-asserted-by":"crossref","first-page":"e67","DOI":"10.1016\/j.acra.2018.06.008","article-title":"Optimization of monoenergetic extrapolations in dual-energy CT for metal artifact reduction in different body regions and orthopedic implants","volume":"26","author":"L Horat","year":"2019","journal-title":"Acad Radiol"},{"issue":"11","key":"ref58","doi-asserted-by":"crossref","first-page":"4524","DOI":"10.1007\/s00330-018-5414-2","article-title":"CT metal artifacts in patients with total hip replacements: for artifact reduction monoenergetic reconstructions and post-processing algorithms are both efficient but not similar","volume":"28","author":"K R Laukamp","year":"2018","journal-title":"Eur Radiol"},{"issue":"03","key":"ref59","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1097\/RCT.0000000000000850","article-title":"Dual-energy computed tomography in loosening of revision hip prosthesis: a comparison between MARS and non-MARS images","volume":"43","author":"M Guzi\u0144ski","year":"2019","journal-title":"J Comput Assist Tomogr"},{"key":"ref60","doi-asserted-by":"crossref","first-page":"115100","DOI":"10.1016\/j.bone.2019.115100","article-title":"Dual-energy estimates of volumetric bone mineral densities in the lumbar spine using quantitative computed tomography better correlate with fracture properties when compared to single-energy BMD outcomes","volume":"130","author":"S Cata\u00f1o Jimenez","year":"2020","journal-title":"Bone"},{"key":"ref61","doi-asserted-by":"crossref","first-page":"109321","DOI":"10.1016\/j.ejrad.2020.109321","article-title":"Diagnostic accuracy of quantitative dual-energy CT-based bone mineral density assessment in comparison to Hounsfield unit measurements using dual x-ray absorptiometry as standard of reference","volume":"132","author":"C Booz","year":"2020","journal-title":"Eur J Radiol"},{"issue":"05","key":"ref62","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1007\/s00256-014-1817-6","article-title":"Visualization of joint and bone using dual-energy CT arthrography with contrast subtraction: in vitro feasibility study using porcine joints","volume":"43","author":"J W Chai","year":"2014","journal-title":"Skeletal Radiol"},{"issue":"10","key":"ref63","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1007\/s00256-010-0932-2","article-title":"CT arthrography: in vitro evaluation of single and dual energy for optimization of technique","volume":"39","author":"N Subhas","year":"2010","journal-title":"Skeletal Radiol"},{"key":"ref64","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.ejmp.2020.10.030","article-title":"Photon-counting CT review","volume":"79","author":"T Flohr","year":"2020","journal-title":"Phys Med"},{"key":"ref65","doi-asserted-by":"crossref","first-page":"112189","DOI":"10.1016\/j.ejrad.2025.112189","article-title":"Photon-counting CT: an updated review of clinical results","volume":"190","author":"J van der Bie","year":"2025","journal-title":"Eur J Radiol"},{"issue":"03","key":"ref67","doi-asserted-by":"crossref","first-page":"03TR01","DOI":"10.1088\/1361-6560\/abc5a5","article-title":"Photon-counting x-ray detectors for CT","volume":"66","author":"M Danielsson","year":"2021","journal-title":"Phys Med Biol"},{"issue":"1175","key":"ref68","doi-asserted-by":"crossref","first-page":"1859","DOI":"10.1093\/bjr\/tqaf124","article-title":"Photon-counting detector CT in musculoskeletal imaging: benefits and outlook","volume":"98","author":"A O El Sadaney","year":"2025","journal-title":"Br J Radiol"},{"issue":"01","key":"ref69","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1186\/s41747-025-00616-8","article-title":"The emerging role of photon-counting detector CT: primary experience on the integrated assessment of acute knee injuries","volume":"9","author":"F M Zijta","year":"2025","journal-title":"Eur Radiol Exp"},{"key":"ref70","doi-asserted-by":"crossref","first-page":"111383","DOI":"10.1016\/j.ejrad.2024.111383","article-title":"A comparative study of image quality and diagnostic confidence in diagnosis and follow-up of scaphoid fractures using photon-counting detector CT and energy-integrating detector CT","volume":"173","author":"N K\u00e4mmerling","year":"2024","journal-title":"Eur J Radiol"},{"issue":"01","key":"ref71","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1148\/radiol.220311","article-title":"Photon-counting detector CT with deep learning noise reduction to detect multiple myeloma","volume":"306","author":"F I Baffour","year":"2023","journal-title":"Radiology"},{"issue":"04","key":"ref72","doi-asserted-by":"crossref","first-page":"2415","DOI":"10.1007\/s00330-022-09225-0","article-title":"Myeloma bone disease imaging on a 1st-generation clinical photon-counting detector CT vs. 2nd-generation dual-source dual-energy CT","volume":"33","author":"M T Winkelmann","year":"2023","journal-title":"Eur Radiol"},{"key":"ref73","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.bone.2015.06.006","article-title":"Human trabecular bone microarchitecture can be assessed independently of density with second generation HR-pQCT","volume":"79","author":"S L Manske","year":"2015","journal-title":"Bone"},{"key":"ref74","doi-asserted-by":"crossref","first-page":"117443","DOI":"10.1016\/j.bone.2025.117443","article-title":"Accuracy and precision of segmentation and quantification of wrist bone microarchitecture using photon-counting computed tomography ex vivo","volume":"194","author":"J Quintiens","year":"2025","journal-title":"Bone"},{"issue":"03","key":"ref75","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1007\/s00256-024-04770-9","article-title":"Quantitative metrics of bone quality determined at the distal radius using photon-counting CT","volume":"54","author":"A Dutta","year":"2025","journal-title":"Skeletal Radiol"},{"key":"ref76","doi-asserted-by":"crossref","first-page":"100646","DOI":"10.1016\/j.ejro.2025.100646","article-title":"Assessment of bone-implant interface image quality for in-vivo acetabular cup implants using photon-counting detector CT: impact of tin pre-filtration","volume":"14","author":"R Booij","year":"2025","journal-title":"Eur J Radiol Open"},{"issue":"01","key":"ref77","doi-asserted-by":"crossref","first-page":"8955","DOI":"10.1038\/s41598-023-35989-6","article-title":"Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT","volume":"13","author":"Y C Layer","year":"2023","journal-title":"Sci Rep"},{"issue":"12","key":"ref78","doi-asserted-by":"crossref","first-page":"9286","DOI":"10.1007\/s00330-023-09879-4","article-title":"Metal artifact reduction in patients with total hip replacements: evaluation of clinical photon counting CT using virtual monoenergetic images","volume":"33","author":"J Schreck","year":"2023","journal-title":"Eur Radiol"},{"issue":"08","key":"ref79","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1097\/RLI.0000000000001058","article-title":"Photon-counting detector CT: clinical utility of virtual monoenergetic imaging combined with tin prefiltration to reduce metal artifacts in the postoperative ankle","volume":"59","author":"A A Marth","year":"2024","journal-title":"Invest Radiol"},{"issue":"06","key":"ref80","doi-asserted-by":"crossref","first-page":"890","DOI":"10.1007\/s11547-024-01822-x","article-title":"Photon-counting detector computed tomography for metal artifact reduction: a comparative study of different artifact reduction techniques in patients with orthopedic implants","volume":"129","author":"F B Pallasch","year":"2024","journal-title":"Radiol Med"},{"issue":"01","key":"ref81","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s41747-023-00335-y","article-title":"Improved visualization of the bone-implant interface and osseointegration in ex vivo acetabular cup implants using photon-counting detector CT","volume":"7","author":"M Woisetschl\u00e4ger","year":"2023","journal-title":"Eur Radiol Exp"},{"issue":"01","key":"ref82","first-page":"tzae015","article-title":"Unlocking the potential of photon counting detector CT for paediatric imaging: a pictorial essay","volume":"6","author":"I Aliukonyte","year":"2024","journal-title":"BJR Open"},{"issue":"01","key":"ref83","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1097\/RCT.0000000000001810","article-title":"Photon-counting CT in children: a literature review","volume":"50","author":"F L Pasadyn","year":"2026","journal-title":"J Comput Assist Tomogr"},{"issue":"01","key":"ref84","doi-asserted-by":"crossref","first-page":"e2431909","DOI":"10.2214\/AJR.24.31909","article-title":"Opportunistic bone mineral density measurement using photon-counting detector CT spectral localizer images: a prospective study","volume":"224","author":"A O El Sadaney","year":"2025","journal-title":"AJR Am J Roentgenol"},{"issue":"08","key":"ref85","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1097\/CORR.0000000000002171","article-title":"Can weightbearing cone-beam CT reliably differentiate between stable and unstable syndesmotic ankle injuries? A systematic review and meta-analysis","volume":"480","author":"F J Raheman","year":"2022","journal-title":"Clin Orthop Relat Res"},{"issue":"18","key":"ref86","doi-asserted-by":"crossref","first-page":"e98","DOI":"10.2106\/JBJS.16.01366","article-title":"Flexible adult acquired flatfoot deformity: comparison between weight-bearing and non-weight-bearing measurements using cone-beam computed tomography","volume":"99","author":"C de Cesar Netto","year":"2017","journal-title":"J Bone Joint Surg Am"},{"issue":"01","key":"ref87","doi-asserted-by":"crossref","first-page":"16139","DOI":"10.1038\/s41598-021-95708-x","article-title":"Angular and linear measurements of adult flexible flatfoot via weight-bearing CT scans and 3D bone reconstruction tools","volume":"11","author":"M Ortolani","year":"2021","journal-title":"Sci Rep"},{"key":"ref88","doi-asserted-by":"publisher","first-page":"5562","DOI":"10.3390\/app14135562","article-title":"Recent innovations brought about by weight-bearing CT imaging in the foot and ankle: a systematic review of the literature","volume":"14","author":"F Lintz","year":"2024","journal-title":"Appl Sci (Basel)"},{"issue":"12","key":"ref89","doi-asserted-by":"crossref","first-page":"2564","DOI":"10.1016\/j.ejrad.2015.09.003","article-title":"Extremity cone-beam CT for evaluation of medial tibiofemoral osteoarthritis: initial experience in imaging of the weight-bearing and non-weight-bearing knee","volume":"84","author":"G K Thawait","year":"2015","journal-title":"Eur J Radiol"},{"issue":"08","key":"ref90","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1016\/j.fas.2019.11.006","article-title":"A cone beam CT based 3D-assessment of bony forefoot geometry after modified Lapidus arthrodesis","volume":"26","author":"C B Scheele","year":"2020","journal-title":"Foot Ankle Surg"},{"issue":"02","key":"ref91","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/RLI.0000000000000603","article-title":"Development of upright computed tomography with area detector for whole-body scans: phantom study, efficacy on workflow, effect of gravity on human body, and potential clinical impact","volume":"55","author":"M Jinzaki","year":"2020","journal-title":"Invest Radiol"},{"issue":"1073","key":"ref92","doi-asserted-by":"crossref","first-page":"20160539","DOI":"10.1259\/bjr.20160539","article-title":"Image quality of cone beam computed tomography for evaluation of extremity fractures in the presence of metal hardware: visual grading characteristics analysis","volume":"90","author":"G M Osgood","year":"2017","journal-title":"Br J Radiol"},{"issue":"10","key":"ref93","doi-asserted-by":"crossref","first-page":"1997","DOI":"10.1007\/s00256-025-04947-w","article-title":"Cone beam CT in the imaging of musculoskeletal trauma: a scoping review","volume":"54","author":"J R Smith","year":"2025","journal-title":"Skeletal Radiol"},{"issue":"03","key":"ref94","doi-asserted-by":"crossref","first-page":"e230143","DOI":"10.1148\/rg.230143","article-title":"Cone-beam CT of the extremities in clinical practice","volume":"44","author":"M K Doan","year":"2024","journal-title":"Radiographics"},{"issue":"18","key":"ref95","doi-asserted-by":"crossref","first-page":"5519","DOI":"10.3390\/jcm13185519","article-title":"Trends in the use of weightbearing computed tomography","volume":"13","author":"A Bernasconi","year":"2024","journal-title":"J Clin Med"},{"issue":"04","key":"ref96","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/j.rcl.2009.04.005","article-title":"CT arthrography, MR arthrography, PET, and scintigraphy in osteoarthritis","volume":"47","author":"P Omoumi","year":"2009","journal-title":"Radiol Clin North Am"},{"issue":"03","key":"ref97","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1148\/radiol.2283020590","article-title":"Postoperative meniscus: assessment at dual-detector row spiral CT arthrography of the knee","volume":"228","author":"C Mutschler","year":"2003","journal-title":"Radiology"},{"issue":"02","key":"ref98","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1148\/radiol.2222010597","article-title":"Assessment of knee cartilage in cadavers with dual-detector spiral CT arthrography and MR imaging","volume":"222","author":"B C Vande Berg","year":"2002","journal-title":"Radiology"},{"issue":"03","key":"ref99","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1148\/radiology.216.3.r00au08851","article-title":"Dual-detector spiral CT arthrography of the knee: accuracy for detection of meniscal abnormalities and unstable meniscal tears","volume":"216","author":"B C Vande Berg","year":"2000","journal-title":"Radiology"},{"issue":"04","key":"ref100","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1007\/s00330-014-3469-2","article-title":"Diagnostic performance of CT-arthrography and 1.5T MR-arthrography for the assessment of glenohumeral joint cartilage: a comparative study with arthroscopic correlation","volume":"25","author":"P Omoumi","year":"2015","journal-title":"Eur Radiol"},{"issue":"03","key":"ref101","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1148\/radiol.12112062","article-title":"Evaluation of rotator cuff tendon tears: comparison of multidetector CT arthrography and 1.5-T MR arthrography","volume":"264","author":"P Omoumi","year":"2012","journal-title":"Radiology"},{"issue":"02","key":"ref102","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1148\/radiol.2232011024","article-title":"Anterior cruciate ligament tears and associated meniscal lesions: assessment at dual-detector spiral CT arthrography","volume":"223","author":"B C Vande Berg","year":"2002","journal-title":"Radiology"},{"issue":"07","key":"ref103","doi-asserted-by":"crossref","first-page":"1800","DOI":"10.1007\/s00330-002-1491-2","article-title":"Spiral CT arthrography of the knee: technique and value in the assessment of internal derangement of the knee","volume":"12","author":"B C Vande Berg","year":"2002","journal-title":"Eur Radiol"},{"issue":"06","key":"ref104","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.2214\/ajr.170.6.9609177","article-title":"Ganglion cysts of the knee: articular communication revealed by delayed radiography and CT after arthrography","volume":"170","author":"J Malghem","year":"1998","journal-title":"AJR Am J Roentgenol"},{"issue":"04","key":"ref105","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1007\/s00256-009-0864-x","article-title":"Value of computed tomography arthrography with delayed acquisitions in the work-up of ganglion cysts of the tarsal tunnel: report of three cases","volume":"39","author":"P Omoumi","year":"2010","journal-title":"Skeletal Radiol"},{"issue":"11","key":"ref106","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1016\/j.diii.2020.09.008","article-title":"3D reconstructions, 4D imaging and postprocessing with CT in musculoskeletal disorders: past, present and future","volume":"101","author":"A Blum","year":"2020","journal-title":"Diagn Interv Imaging"},{"issue":"02","key":"ref108","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1007\/s00330-016-4362-y","article-title":"Evidence-based recommendations for musculoskeletal kinematic 4D-CT studies using wide area-detector scanners: a phantom study with cadaveric correlation","volume":"27","author":"P A Gondim Teixeira","year":"2017","journal-title":"Eur Radiol"},{"key":"ref109","doi-asserted-by":"crossref","first-page":"111544","DOI":"10.1016\/j.ejrad.2024.111544","article-title":"Post-processing of quantitative 4D-CT for initial evaluation of scapholunate instability: assessment of simplified approaches to data analysis","volume":"177","author":"B Ayoub","year":"2024","journal-title":"Eur J Radiol"},{"issue":"05","key":"ref110","doi-asserted-by":"crossref","first-page":"101762","DOI":"10.1016\/j.hansur.2024.101762","article-title":"Clinical, radiological and dynamic CT results of scapholunate intercarpal ligamentoplasty for scapholunate dissociation","volume":"43","author":"L Athlani","year":"2024","journal-title":"Hand Surg Rehabil"},{"issue":"03","key":"ref111","doi-asserted-by":"crossref","first-page":"e230193","DOI":"10.1148\/radiol.230193","article-title":"Assessment of scapholunate instability on 4D CT scans in patients with inconclusive conventional images","volume":"308","author":"S Orkut","year":"2023","journal-title":"Radiology"},{"key":"ref112","doi-asserted-by":"crossref","first-page":"112450","DOI":"10.1016\/j.ejrad.2025.112450","article-title":"Four-dimensional CT analysis of patellofemoral instability: a prospective cohort study","volume":"194","author":"M Lumia","year":"2026","journal-title":"Eur J Radiol"},{"key":"ref113","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.knee.2022.12.011","article-title":"Fully automatic extraction of knee kinematics from dynamic CT imaging; normative tibiofemoral and patellofemoral kinematics of 100 healthy volunteers","volume":"41","author":"H Dunning","year":"2023","journal-title":"Knee"},{"issue":"02","key":"ref114","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.jcct.2017.11.008","article-title":"Dynamic CT angiography for the diagnosis of patients with thoracic outlet syndrome: correlation with patient symptoms","volume":"12","author":"R Gillet","year":"2018","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"04","key":"ref115","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1097\/RCT.0000000000000410","article-title":"The use of a dynamic 4-dimensional computed tomography scan in the diagnosis of atraumatic posterior sternoclavicular joint instability","volume":"40","author":"J L Hislop-Jambrich","year":"2016","journal-title":"J Comput Assist Tomogr"},{"key":"ref116","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.ejrad.2019.03.001","article-title":"Comparison between subtalar joint quantitative kinematic 4-D CT parameters in healthy volunteers and patients with joint stiffness or chronic ankle instability: a preliminary study","volume":"114","author":"P A Gondim Teixeira","year":"2019","journal-title":"Eur J Radiol"},{"issue":"04","key":"ref117","doi-asserted-by":"crossref","first-page":"e83","DOI":"10.1016\/j.jse.2014.09.020","article-title":"Four-dimensional computed tomography scans facilitate preoperative planning in snapping scapula syndrome","volume":"24","author":"S N Bell","year":"2015","journal-title":"J Shoulder Elbow Surg"},{"issue":"01","key":"ref118","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/RLI.0000000000000916","article-title":"Synthetic CT in musculoskeletal disorders: a systematic review","volume":"58","author":"A F Lombardi","year":"2023","journal-title":"Invest Radiol"},{"issue":"01","key":"ref119","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1097\/RLI.0000000000000917","article-title":"Synthetic contrasts in musculoskeletal MRI: a review","volume":"58","author":"T Hilbert","year":"2023","journal-title":"Invest Radiol"},{"key":"ref120","doi-asserted-by":"crossref","first-page":"109915","DOI":"10.1016\/j.ejrad.2021.109915","article-title":"3D MRI with CT-like bone contrast: an overview of current approaches and practical clinical implementation","volume":"143","author":"L R Chong","year":"2021","journal-title":"Eur J Radiol"},{"issue":"02","key":"ref121","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1148\/radiol.2020201537","article-title":"MRI-based synthetic CT in the detection of structural lesions in patients with suspected sacroiliitis: comparison with MRI","volume":"298","author":"L BO Jans","year":"2021","journal-title":"Radiology"},{"issue":"01","key":"ref122","doi-asserted-by":"crossref","first-page":"e231817","DOI":"10.1148\/radiol.231817","article-title":"MRI-based zero echo time and black bone pseudo-CT compared with whole-body CT to detect osteolytic lesions in multiple myeloma","volume":"313","author":"F E Lecouvet","year":"2024","journal-title":"Radiology"},{"issue":"01","key":"ref123","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1186\/s41747-025-00585-y","article-title":"MRI-based pseudo-CT sequences as a radiation-free alternative to CT for obstetric pelvimetry: a proof-of-concept study","volume":"9","author":"C Chabot","year":"2025","journal-title":"Eur Radiol Exp"},{"issue":"02","key":"ref124","doi-asserted-by":"crossref","first-page":"e2022061027","DOI":"10.1542\/peds.2022-061027","article-title":"Synthetic CT assessment of lesions in children with rare musculoskeletal diseases","volume":"152","author":"J Upadhyay","year":"2023","journal-title":"Pediatrics"},{"key":"ref125","doi-asserted-by":"crossref","first-page":"109870","DOI":"10.1016\/j.ejrad.2021.109870","article-title":"Orthopaedic surgeons do not consult radiology reports. Fact or fiction?","volume":"142","author":"R Donners","year":"2021","journal-title":"Eur J Radiol"},{"issue":"06","key":"ref126","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1136\/ijgc-2023-005264","article-title":"Patient satisfaction with ultrasound, whole-body CT and whole-body diffusion-weighted MRI for pre-operative ovarian cancer staging: a multicenter prospective cross-sectional survey","volume":"34","author":"P Pinto","year":"2024","journal-title":"Int J Gynecol Cancer"},{"key":"ref127","first-page":"23","article-title":"Patient satisfaction in outpatient radiology: effects of modality and patient demographic characteristics","volume":"8","author":"A A Ajam","year":"2021","journal-title":"J Patient Exp"},{"key":"ref128","doi-asserted-by":"crossref","first-page":"100251","DOI":"10.1016\/j.ostima.2024.100251","article-title":"Standardized maps \u2013 an emerging approach to leverage quantitative information in knee imaging","volume":"4","author":"P Margain","year":"2024","journal-title":"Osteoarthr Imaging"},{"issue":"04","key":"ref129","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1055\/s-0040-1710356","article-title":"The value of quantitative musculoskeletal imaging","volume":"24","author":"J J Visser","year":"2020","journal-title":"Semin Musculoskelet Radiol"},{"issue":"01","key":"ref130","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1055\/s-0039-3400268","article-title":"Quantification in musculoskeletal imaging using computational analysis and machine learning: segmentation and radiomics","volume":"24","author":"M Bach Cuadra","year":"2020","journal-title":"Semin Musculoskelet Radiol"}],"container-title":["Seminars in Musculoskeletal Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2826-6432.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T22:58:06Z","timestamp":1784588286000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2826-6432"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,4]]},"references-count":128,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2026,7,20]]},"published-print":{"date-parts":[[2026,8]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2826-6432","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["1089-7860","1098-898X"],"issn-type":[{"value":"1089-7860","type":"print"},{"value":"1098-898X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,4]]}}}