{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T19:11:50Z","timestamp":1790795510466,"version":"4.1.0"},"reference-count":27,"publisher":"Georg Thieme Verlag KG","issue":"04","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Neurol Surg A Cent Eur Neurosurg"],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The anchor at C2 often serves as a key stabilizer in cervical spine fusion surgery. Although the pedicle screw is considered the standard fixation method at C2, the laminar screw is also a widely used alternative due to its biomechanical stability, comparable to that of C2 PS. However, malpositioning of C2 LS carries a risk of neural injury and compromised fixation stability, and the use of surgical assistance has been reported to improve placement accuracy. The robotic system is a relatively new technology for PS placement, and its application has recently expanded to the cervical spine. The present study aimed to investigate the accuracy of C2 laminar screw placement with robot assistance.<\/jats:p>\n                  <jats:p>This prospective study evaluated 11 C2 laminar screws in 11 patients who underwent cervical fusion surgery with the robot assistance between March 2024 and June 2025.<\/jats:p>\n                  <jats:p>All 11 C2 laminar screws were successfully placed with no cortical breaches and no screw-related complications. The mean deviations at both the entry point and at a depth of 20\u2009mm were less than 1.0\u2009mm in both the axial and sagittal planes.<\/jats:p>\n                  <jats:p>The results of this study suggest that the robotic system is a potential tool to facilitate accurate C2 laminar screw placement in clinical settings.<\/jats:p>","DOI":"10.1055\/a-2840-7567","type":"journal-article","created":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T00:08:22Z","timestamp":1774483702000},"page":"287-293","source":"Crossref","is-referenced-by-count":1,"title":["Robotic-Assisted C2 Laminar Screw Placement: Initial Experience and Accuracy Evaluation"],"prefix":"10.1055","volume":"87","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-8072-9507","authenticated-orcid":false,"given":"Yuki","family":"Yamamoto","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Fujishiro","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fumiya","family":"Adachi","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuya","family":"Obo","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sachio","family":"Hayama","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masashi","family":"Neo","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuhei","family":"Otsuki","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2026,4,24]]},"reference":[{"issue":"14","key":"ref1","doi-asserted-by":"crossref","first-page":"E936","DOI":"10.1097\/BRS.0b013e3181fdaf06","article-title":"Posterior C2 instrumentation: accuracy and complications associated with four techniques","volume":"36","author":"R J Bransford","year":"2011","journal-title":"Spine"},{"issue":"01","key":"ref2","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/00002517-199407010-00003","article-title":"Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report","volume":"7","author":"K Abumi","year":"1994","journal-title":"J Spinal Disord"},{"issue":"09","key":"ref3","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1097\/00007632-199705010-00009","article-title":"Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison","volume":"22","author":"E L Jones","year":"1997","journal-title":"Spine"},{"issue":"06","key":"ref4","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.spinee.2006.03.019","article-title":"Cervical pedicle screws vs. lateral mass screws: uniplanar fatigue analysis and residual pullout strengths","volume":"6","author":"T L Johnston","year":"2006","journal-title":"Spine J"},{"issue":"02","key":"ref5","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1097\/00024720-200404000-00014","article-title":"Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note","volume":"17","author":"N M Wright","year":"2004","journal-title":"J Spinal Disord Tech"},{"issue":"13","key":"ref6","doi-asserted-by":"crossref","first-page":"1513","DOI":"10.1097\/01.brs.0000167827.84020.49","article-title":"Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation","volume":"30","author":"J Gorek","year":"2005","journal-title":"Spine"},{"issue":"03","key":"ref7","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1227\/01.NEU.0000197222.05299.31","article-title":"Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws","volume":"58","author":"S B Lapsiwala","year":"2006","journal-title":"Neurosurgery"},{"issue":"04","key":"ref8","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1007\/s00590-013-1349-0","article-title":"The reinforcement of a C2 laminar screw by a C2 laminar hook as an anchor of occipito-C2 fusion","volume":"24","author":"M Neo","year":"2014","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"24","key":"ref9","doi-asserted-by":"crossref","first-page":"2800","DOI":"10.1097\/01.brs.0000192297.07709.5d","article-title":"The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae","volume":"30","author":"M Neo","year":"2005","journal-title":"Spine"},{"issue":"07","key":"ref10","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1097\/01.BRS.0000051919.14927.57","article-title":"Atlantoaxial transarticular screw fixation for a high-riding vertebral artery","volume":"28","author":"M Neo","year":"2003","journal-title":"Spine"},{"issue":"05","key":"ref11","doi-asserted-by":"crossref","first-page":"888","DOI":"10.31616\/asj.2023.0233","article-title":"The feasibility of multiple fixation points in C2","volume":"17","author":"Q N Ngoc","year":"2023","journal-title":"Asian Spine J"},{"issue":"12","key":"ref12","doi-asserted-by":"crossref","first-page":"2771","DOI":"10.1007\/s00586-015-4165-x","article-title":"Use of intraoperative fluoroscopy for the safe placement of C2 laminar screws: technical note","volume":"24","author":"J A Engler","year":"2015","journal-title":"Eur Spine J"},{"issue":"26","key":"ref13","doi-asserted-by":"crossref","first-page":"3036","DOI":"10.1097\/BRS.0b013e31815cdab9","article-title":"Accuracy of intraoperative plain radiographs to detect violations of intralaminar screws placed into the C2 vertebrae: a reliability study","volume":"32","author":"R A Lehman Jr","year":"2007","journal-title":"Spine"},{"issue":"05","key":"ref14","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1007\/s00586-021-06739-x","article-title":"3D-printed drill guide template, a promising tool to improve pedicle screw placement accuracy in spinal deformity surgery: A systematic review and meta-analysis","volume":"30","author":"W Liang","year":"2021","journal-title":"Eur Spine J"},{"issue":"02","key":"ref15","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","article-title":"Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques","volume":"21","author":"I D Gelalis","year":"2012","journal-title":"Eur Spine J"},{"issue":"04","key":"ref16","doi-asserted-by":"crossref","first-page":"614","DOI":"10.3390\/tomography7040052","article-title":"Cervical spine pedicle screw accuracy in fluoroscopic, navigated and template guided systems-a systematic review","volume":"7","author":"A Mahmoud","year":"2021","journal-title":"Tomography"},{"issue":"04","key":"ref17","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1007\/s00586-007-0557-x","article-title":"Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance","volume":"17","author":"E W Nottmeier","year":"2008","journal-title":"Eur Spine J"},{"issue":"09","key":"ref18","doi-asserted-by":"crossref","first-page":"1379","DOI":"10.1007\/s00586-009-1051-4","article-title":"A novel computer-assisted drill guide template for placement of C2 laminar screws","volume":"18","author":"S Lu","year":"2009","journal-title":"Eur Spine J"},{"issue":"02","key":"ref19","doi-asserted-by":"crossref","first-page":"231","DOI":"10.3171\/2014.3.SPINE13730","article-title":"A novel screw guiding method with a screw guide template system for posterior C-2 fixation: clinical article","volume":"21","author":"S Kaneyama","year":"2014","journal-title":"J Neurosurg Spine"},{"issue":"02","key":"ref20","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.spinee.2022.10.006","article-title":"Robotic and navigated pedicle screws are safer and more accurate than fluoroscopic freehand screws: a systematic review and meta-analysis","volume":"23","author":"A V Matur","year":"2023","journal-title":"Spine J"},{"issue":"01","key":"ref21","doi-asserted-by":"crossref","first-page":"66","DOI":"10.3171\/2022.7.SPINE22473","article-title":"Spinal robotics in cervical spine surgery: a systematic review with key concepts and technical considerations","volume":"38","author":"R S Beyer","year":"2022","journal-title":"J Neurosurg Spine"},{"issue":"10","key":"ref22","doi-asserted-by":"crossref","first-page":"E424","DOI":"10.1097\/BSD.0000000000001616","article-title":"Comparison of cervical pedicle screw placement accuracy with robotic guidance system versus image guidance system using propensity score matching","volume":"37","author":"Y Yamamoto","year":"2024","journal-title":"Clin Spine Surg"},{"issue":"03","key":"ref23","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1007\/s00586-022-07110-4","article-title":"Robotic-guided placement of cervical pedicle screws: feasibility and accuracy","volume":"31","author":"S Kisinde","year":"2022","journal-title":"Eur Spine J"},{"issue":"06","key":"ref24","doi-asserted-by":"crossref","first-page":"E13","DOI":"10.3171\/2024.9.FOCUS24431","article-title":"Accuracy of cervical pedicle screw placement with a robotic guidance system via the open midline approach","volume":"57","author":"Y Yamamoto","year":"2024","journal-title":"Neurosurg Focus"},{"issue":"07","key":"ref25","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/nmeth.2089","article-title":"NIH Image to ImageJ: 25 years of image analysis","volume":"9","author":"C A Schneider","year":"2012","journal-title":"Nat Methods"},{"issue":"01","key":"ref26","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"J R Landis","year":"1977","journal-title":"Biometrics"},{"issue":"24","key":"ref27","doi-asserted-by":"crossref","first-page":"1882","DOI":"10.1097\/BRS.0000000000001099","article-title":"Accuracy of pedicle screw placement with robotic guidance system: a cadaveric study","volume":"40","author":"T Fujishiro","year":"2015","journal-title":"Spine"}],"container-title":["Journal of Neurological Surgery Part A: Central European Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2840-7567.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T22:38:04Z","timestamp":1781217484000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2840-7567"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,25]]},"references-count":27,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2026,6,11]]},"published-print":{"date-parts":[[2026,7]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2840-7567","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["2193-6315","2193-6323"],"issn-type":[{"value":"2193-6315","type":"print"},{"value":"2193-6323","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,3,25]]},"published":{"date-parts":[[2026,3,25]]}}}