{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T23:23:52Z","timestamp":1792452232300,"version":"4.5.0"},"reference-count":7,"publisher":"Georg Thieme Verlag KG","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neuropediatrics"],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Magnetic resonance imaging (MRI) is the imaging of choice to diagnose brain injury and prognosticate long-term neurodevelopmental outcomes in infants with hypoxic\u2013ischemic encephalopathy (HIE). Independent scoring from Neuroradiology and Neonatology fellows was obtained for 97 brain MRIs for HIE after teaching. Analysis for reliability was compared against a gold standard of an experienced Neuroradiologist. There was good (intraclass correlation coefficient: 0.87) reliability for the Neonatology fellow and excellent (intraclass correlation coefficient: 0.94) reliability for the Neuroradiology fellow compared with the Neuroradiologist. This suggests that the scoring system used has good interobserver reliability between less experienced readers compared with an experienced reader.<\/jats:p>","DOI":"10.1055\/a-2844-7341","type":"journal-article","created":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T22:53:08Z","timestamp":1774911188000},"page":"223-225","source":"Crossref","is-referenced-by-count":1,"title":["The Weeke Score Is an Easy-to-Teach and Reliable System for Hypoxic\u2013Ischemic Encephalopathy Brain Magnetic Resonance Imaging Scoring"],"prefix":"10.1055","volume":"57","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-9903-1139","authenticated-orcid":false,"given":"Jun","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zarina","family":"Assis","sequence":"additional","affiliation":[{"name":"Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sujith Kumar Reddy Gurram","family":"Venkata","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Section of Newborn Critical Care, University of Calgary Cumming School of Medicine, Calgary, Alberta, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Scott","sequence":"additional","affiliation":[{"name":"Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mao","family":"Ding","sequence":"additional","affiliation":[{"name":"University of Calgary Cumming School of Medicine, Calgary, Alberta, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lara","family":"Leijser","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Section of Newborn Critical Care, University of Calgary Cumming School of Medicine, Calgary, Alberta, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hussein","family":"Zein","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Section of Newborn Critical Care, University of Calgary Cumming School of Medicine, Calgary, Alberta, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khorshid","family":"Mohammad","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Section of Newborn Critical Care, University of Calgary Cumming School of Medicine, Calgary, Alberta, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2026,4,9]]},"reference":[{"issue":"06","key":"ref1","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/j.earlhumdev.2010.05.010","article-title":"Epidemiology of neonatal encephalopathy and hypoxic-ischaemic encephalopathy","volume":"86","author":"J J Kurinczuk","year":"2010","journal-title":"Early Hum Dev"},{"issue":"01","key":"ref2","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1542\/peds.2012-1297","article-title":"Prognostic tests in term neonates with hypoxic-ischemic encephalopathy: a systematic review","volume":"131","author":"H van Laerhoven","year":"2013","journal-title":"Pediatrics"},{"issue":"01","key":"ref3","first-page":"143","article-title":"Prediction of neuromotor outcome in perinatal asphyxia: evaluation of MR scoring systems","volume":"19","author":"A J Barkovich","year":"1998","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.jpeds.2017.09.043","article-title":"A novel magnetic resonance imaging score predicts neurodevelopmental outcome after perinatal asphyxia and therapeutic hypothermia","volume":"192","author":"L C Weeke","year":"2018","journal-title":"J Pediatr"},{"issue":"03","key":"ref5","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1159\/000522629","article-title":"Outcome prediction and inter-rater comparison of four brain magnetic resonance imaging scoring systems of infants with perinatal asphyxia and therapeutic hypothermia","volume":"119","author":"J F Langeslag","year":"2022","journal-title":"Neonatology"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.pediatrneurol.2021.10.005","article-title":"Relationship between MRI scoring systems and neurodevelopmental outcome at two years in infants with neonatal encephalopathy","volume":"126","author":"M N\u00ed Bhroin","year":"2022","journal-title":"Pediatr Neurol"},{"issue":"08","key":"ref7","first-page":"1295","article-title":"Correlation of different MRI scoring systems with long-term cognitive outcome in cooled asphyxiated newborns","volume":"10","author":"O H Kang","year":"2023","journal-title":"Children (Basel)"}],"container-title":["Neuropediatrics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2844-7341.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T22:39:28Z","timestamp":1780526368000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2844-7341"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,30]]},"references-count":7,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2026,6,3]]},"published-print":{"date-parts":[[2026,6]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2844-7341","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0174-304X","1439-1899"],"issn-type":[{"value":"0174-304X","type":"print"},{"value":"1439-1899","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,3,30]]},"published":{"date-parts":[[2026,3,30]]}}}