{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T23:16:06Z","timestamp":1788477366666,"version":"build-2803163510"},"reference-count":19,"publisher":"Georg Thieme Verlag KG","issue":"09","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Laryngorhinootologie"],"published-print":{"date-parts":[[2026,9]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title>\n                  <jats:p>Das piezoelektrische OSIA ist ein etabliertes aktives transkutanes Knochenleitungsh\u00f6rsystem. Die Studie analysiert retrospektiv die H\u00f6rergebnisse und den subjektiven Gewinn durch die Versorgung mit OSIA bei den in unserer Klinik implantierten Personen und betrachtet gesondert die Patienten mit mittel- und hochgradiger kombinierter Schwerh\u00f6rigkeit.<\/jats:p>\n                  <jats:p>21 Patienten im Alter zwischen 9 und 83 Jahren wurden zwischen 2022 und 2024 f\u00fcr eine OSIA-Implantation vorgesehen. Pr\u00e4operativ (k0) sowie nach 3 (k1) und 6 Monaten (k2) mit OSIA wurden H\u00f6rtests und Lebensqualit\u00e4tsbefragungen durchgef\u00fchrt.<\/jats:p>\n                  <jats:p>Die k0-PTA4-Luftleitungsschwelle betrug 68,2dB (\u00b116,7). Die PTA4-Freifeldh\u00f6rschwelle mit OSIA zu k1 betrug 32,0dB (\u00b114,1). Der Gewinn ist substanzielle 36,2dB. Das Freiburger Einsilberverstehen in Ruhe bei 65dB mit dem OSIA zu k1 war um 16,4% besser als die k0-H\u00f6rleistung mit dem BAHA 6 Max. Die postoperative Freiburger-Einsilbertest-H\u00f6rleistung bei 65dB war statistisch signifikant besser mit OSIA als ohne. Es wurde eine signifikante negative Korrelation zwischen pr\u00e4- und postoperativen APHAB- und NCIQ-Antworten festgestellt (Korrelationskoeffizient \u20130,87). Die postoperativen Tinnitusresultate korrelierten mit den APHAB- und den NCIQ-Ergebnissen (Korrelationskoeffizient 0,72 bzw. \u20130,81).<\/jats:p>\n                  <jats:p>Insgesamt konnten wir eine signifikante Verbesserung der H\u00f6rschwellen, des Sprachverstehens und der subjektiven Lebensqualit\u00e4t bei den mit OSIA implantierten Patienten feststellen. Auch in der Untergruppe der mittel- bis hochgradig kombiniert schwerh\u00f6rigen Patienten wurden im zeitlichen Verlauf eine stetige Verbesserung des Sprachverstehens und eine gute Lebensqualit\u00e4t und hohe Zufriedenheit mit dem System gesehen.<\/jats:p>","DOI":"10.1055\/a-2883-5095","type":"journal-article","created":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T23:02:26Z","timestamp":1782428546000},"page":"567-579","source":"Crossref","is-referenced-by-count":0,"title":["H\u00f6rergebnisse und Lebensqualit\u00e4t bei OSIA-Tr\u00e4gern \u2013 eine retrospektive monozentrische Studie"],"prefix":"10.1055","volume":"105","author":[{"given":"Ioana","family":"Brill","sequence":"additional","affiliation":[{"name":"Ruhr-Universit\u00e4t Bochum, Germany","place":["Bochum"],"department":["HNO-Universit\u00e4tsklinik Bochum"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Dazert","sequence":"additional","affiliation":[{"name":"Ruhr-Universit\u00e4t Bochum, Germany","place":["Bochum"],"department":["HNO-Universit\u00e4tsklinik Bochum"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2026,6,25]]},"reference":[{"issue":"09","key":"ref1","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1097\/MAO.0000000000002794","article-title":"Multicenter Clinical Investigation of a New Active Osseointegrated Steady-State Implant System","volume":"41","author":"EA Mylanus","year":"2020","journal-title":"Otol Neurotol"},{"issue":"05","key":"ref4","doi-asserted-by":"publisher","first-page":"2217","DOI":"10.1007\/s00405-022-07715-x","article-title":"A comparative study of audiological outcomes and compliance between the Osia system and other bone conductive hearing implants","volume":"280","author":"Y Kim","year":"2022","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"02","key":"ref5","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1097\/00003446-199504000-0005","article-title":"The abbreviated profile of hearing aid benefit","volume":"16","author":"RM Cox","year":"1995","journal-title":"Ear Hear"},{"issue":"06","key":"ref6","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1067\/mhn.2000.108203","article-title":"Development and application of a health-related quality-of-life instrument for adults with cochlear implants: the Nijmegen cochlear implant questionnaire","volume":"123","author":"JB Hinderink","year":"2000","journal-title":"Otolaryngol Heas Neck Surg"},{"issue":"02","key":"ref7","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1067\/mhn.2000.108203","article-title":"Corrigendum for [6]","volume":"156","year":"2017","journal-title":"Otolaryngol Head Neck Surg"},{"issue":"02","key":"ref9","doi-asserted-by":"publisher","first-page":"2767","DOI":"10.1007\/s00405-025-09202-5","article-title":"How I do it: Modified operation technique for MR Conditional OSIA 3: anterior based flap for covering the implant","volume":"282","author":"IT Brill","year":"2025","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"10","key":"ref11","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1080\/14992020400050077","article-title":"Rapid assessment of tinnitus-related psychological distress using the Mini-TQ","volume":"43","author":"W Hiller","year":"2004","journal-title":"Int J Audiol"},{"issue":"03","key":"ref12","first-page":"166","article-title":"The tinnitus questionnaire. A standard instrument for grading the degree of tinnitus. Results from a multicenter study wuth the tinnitus questionnaire","volume":"42","author":"G Goebel","year":"1994","journal-title":"HNO"},{"issue":"11","key":"ref13","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1007\/s00106-023-01365-z","article-title":"Itemanalyse der Kurzformen des Tinnitusfragebogens: Mini-TF-12 und Mini-TF-15","volume":"71","author":"P Bruggemann","year":"2023","journal-title":"HNO"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-24277-4","volume-title":"ggplot2: Elegant Graphics for Data Analysis","author":"H Wickham","year":"2016"},{"issue":"06","key":"ref16","doi-asserted-by":"publisher","first-page":"11","DOI":"10.5604\/01.3001.0014.9342","article-title":"Piezoelectric bone conduction hearing implant Osia \u2013 audiological and quality of life benefits","volume":"75","author":"J Marszal","year":"2021","journal-title":"Otolaryngol Pol"},{"issue":"07","key":"ref18","doi-asserted-by":"publisher","first-page":"e905","DOI":"10.1097\/MAO.0000000000003116","article-title":"Clinical Performance Assessment of a New Active Osseointegrated Implant System in Mixed Hearing Loss: Results From a Prospective Clinical Investigation Otol Neurotol","volume":"42","author":"I Pla-Gil","year":"2021"},{"issue":"09","key":"ref19","doi-asserted-by":"publisher","first-page":"4279","DOI":"10.1007\/s00405-021-07167-9","article-title":"Long-term data of the new transcoutaneous partially implantable bone conduction hearing system Eur Arch Otorhinolaryngol","volume":"279","author":"AK Rauch","year":"2022"},{"issue":"02","key":"ref20","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1097\/MAO.0000000000003426.","article-title":"Early Outcomes of a New Active Transcutaneous Bone Conduction Implant in Pediatric Patients","volume":"43","author":"P You","year":"2022","journal-title":"Otol Neurotol"},{"issue":"04","key":"ref21","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1002\/lary.31053","article-title":"Systemic Review and Meta-Analysis of a New Active Transcoutaneous Bone Conduction Implant","volume":"134","author":"S Key","year":"2024","journal-title":"Laryngoscope"},{"issue":"11","key":"ref22","doi-asserted-by":"publisher","first-page":"2995","DOI":"10.1007\/s00405-020-06022-7.","article-title":"First United Kingdom experience of the novel Osia active transcutaneous piezoelectric bone conduction implant","volume":"277","author":"K Lau","year":"2020","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"03","key":"ref23","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1080\/00016489.2019.1691744.","article-title":"Clinical performance of the Osia system, a new active osseointegrated implant system. Results from a prospective clinical investigation","volume":"140","author":"M Goycoolea","year":"2020","journal-title":"Acta Otolaryngol"},{"issue":"02","key":"ref24","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1097\/MAO.0000000000000208.","article-title":"Preliminary functional results and quality of life after implantation of a new bone conduction hearing device in patients with conductive and mixed hearing loss","volume":"35","author":"F Ihler","year":"2014","journal-title":"Otol Neurotol"},{"issue":"01","key":"ref25","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1159\/000515489.","article-title":"A New Active Osseointegrated Implant System in Patients with Single-Sided Deafness","volume":"27","author":"K Willenborg","year":"2022","journal-title":"Audiol Neurootol"}],"container-title":["Laryngo-Rhino-Otologie"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2883-5095.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T22:30:43Z","timestamp":1788474643000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2883-5095"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,25]]},"references-count":19,"journal-issue":{"issue":"09","published-online":{"date-parts":[[2026,9,3]]},"published-print":{"date-parts":[[2026,9]]}},"URL":"https:\/\/doi.org\/10.1055\/a-2883-5095","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0935-8943","1438-8685"],"issn-type":[{"value":"0935-8943","type":"print"},{"value":"1438-8685","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,25]]}}}