{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T01:02:51Z","timestamp":1784941371688,"version":"3.55.0"},"reference-count":23,"publisher":"Georg Thieme Verlag KG","issue":"CP","license":[{"start":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T00:00:00Z","timestamp":1783468800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Endosc Int Open"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Background Colorectal cancer is the third leading cause of cancer death worldwide. Colonoscopy can prevent this complication but is imperfect because of missed adenoma. A device involving a variable-rigidity balloon has been developed: G-EYE colonoscopy (GEYEC). Only a few prospective studies on GEYEC are available. We compared GEYEC to standard colonoscopy (SC) during screening colonoscopy.<\/jats:p>\n                  <jats:p>Methods We performed a single-center back-to-back colonoscopy tandem randomized clinical trial. Patients older than 50 years were referred for screening colonoscopy, among whom one-third with a positive fecal immunochemical test were included. In Arm A, patients underwent SC followed by GEYEC; in Arm B, the opposite occurred. The primary objective was to assess and compare adenoma miss rate (AMR) between arms. The secondary objectives were to compare advanced AMRs (aAMRs), adverse events for each colonoscope and withdrawal stability rates for GEYEC.<\/jats:p>\n                  <jats:p>Results One hundred ninety-five patients were included between January 2020 and June 2023. A total of 164 patients (83 women, 51%) completed the two procedures, performed by six experienced operators. The mean AMRs were 0.438 in Arm A and 0.393 in Arm B (p = 0.713). The mean aAMRs were 0.176 in Arm A and 0.036 in Arm B (p = 0.76). The rate of significant adverse events (\u2265AGREE II) was 1.8%, and none were attributed to the GEYEC balloon. In 79% of cases, operators felt that GEYEC provided more stability during withdrawal.<\/jats:p>\n                  <jats:p>Conclusion Although it is reliable and safe, compared with SC, GEYEC does not reduce AMR or aAMR. However, it increases the comfort of scope withdrawal during screening.<\/jats:p>","DOI":"10.1055\/a-2901-5859","type":"journal-article","created":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T23:27:01Z","timestamp":1783553221000},"source":"Crossref","is-referenced-by-count":0,"special_numbering":"S","title":["A Balloon-assisted Colonoscope does not Increase the Adenoma Miss Rate: Outcomes of a Single-center Tandem Randomized Clinical Trial"],"prefix":"10.1055","volume":"14","clinical-trial-number":[{"clinical-trial-number":"nct03961893","registry":"10.18810\/clinical-trials-gov"}],"author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3490-4249","authenticated-orcid":false,"given":"Jean-Philippe","family":"Ratone","sequence":"additional","affiliation":[{"name":"Paoli-Calmettes Institute, Provence-Alpes-C\u00f4te d\u2019Azur, France","place":["Marseille"],"department":["Endoscopy Unit"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanis","family":"Dahel","sequence":"additional","affiliation":[{"name":"Paoli-Calmettes Institute, Provence-Alpes-C\u00f4te d\u2019Azur, France","place":["Marseille"],"department":["Endoscopy Unit"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristophe","family":"Zemmour","sequence":"additional","affiliation":[{"name":"Paoli-Calmettes Institute, Provence-Alpes-C\u00f4te d\u2019Azur, France","place":["Marseille"],"department":["Clinical & Innovation Research Direction, Biostastistics & Methodology Unit"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sol\u00e8ne","family":"Hoibian","sequence":"additional","affiliation":[{"name":"Paoli-Calmettes Institute, Provence-Alpes-C\u00f4te d\u2019Azur, France","place":["Marseille"],"department":["Endoscopy Unit"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Pesenti","sequence":"additional","affiliation":[{"name":"Paoli-Calmettes Institute, Provence-Alpes-C\u00f4te d\u2019Azur, France","place":["Marseille"],"department":["Endoscopy Unit"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florat","family":"Poizat","sequence":"additional","affiliation":[{"name":"Paoli-Calmettes Institute, Provence-Alpes-C\u00f4te d\u2019Azur, France","place":["Marseille"],"department":["Pathology Unit"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Giovannini","sequence":"additional","affiliation":[{"name":"Paoli-Calmettes Institute, Provence-Alpes-C\u00f4te d\u2019Azur, France","place":["Marseille"],"department":["Endoscopy Unit"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabrice","family":"Caillol","sequence":"additional","affiliation":[{"name":"Paoli-Calmettes Institute, Provence-Alpes-C\u00f4te d\u2019Azur, France","place":["Marseille"],"department":["Endoscopy Unit"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2026,7,24]]},"reference":[{"issue":"03","key":"ref1","first-page":"209","article-title":"Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries","volume":"71","author":"H Sung","year":"2021","journal-title":"CA Cancer J Clin"},{"issue":"08","key":"ref2","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1056\/NEJMoa1100370","article-title":"Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths","volume":"366","author":"A G Zauber","year":"2012","journal-title":"N Engl J Med"},{"issue":"12","key":"ref3","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1056\/NEJMoa1301969","article-title":"Long-term colorectal-cancer incidence and mortality after lower endoscopy","volume":"369","author":"R Nishihara","year":"2013","journal-title":"N Engl J Med"},{"issue":"14","key":"ref4","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1056\/NEJMoa1309086","article-title":"Adenoma detection rate and risk of colorectal cancer and death","volume":"370","author":"D A Corley","year":"2014","journal-title":"N Engl J Med"},{"issue":"01","key":"ref5","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.gie.2014.07.058","article-title":"Quality indicators for colonoscopy","volume":"81","author":"D K Rex","year":"2015","journal-title":"Gastrointest Endosc"},{"issue":"11","key":"ref6","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1080\/17474124.2023.2273990","article-title":"Adenoma detection rate in colonoscopy: how can it be improved?","volume":"17","author":"M Spadaccini","year":"2023","journal-title":"Expert Rev Gastroenterol Hepatol"},{"issue":"12","key":"ref7","doi-asserted-by":"crossref","first-page":"2066","DOI":"10.1111\/jgh.15155","article-title":"Endocuff-assisted colonoscopy versus cap-assisted colonoscopy for adenoma detection rate: a meta-analysis of randomized controlled trials","volume":"35","author":"A Li","year":"2020","journal-title":"J Gastroenterol Hepatol"},{"issue":"03","key":"ref8","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/S1470-2045(14)70020-8","article-title":"Standard forward-viewing colonoscopy versus full-spectrum endoscopy: an international, multicentre, randomised, tandem colonoscopy trial","volume":"15","author":"I M Gralnek","year":"2014","journal-title":"Lancet Oncol"},{"issue":"05","key":"ref9","first-page":"512","article-title":"Impact of full Spectrum endoscopy(R) (Fuse(R), EndoChoice(R)) on adenoma detection: a prospective French pilot study","volume":"30","author":"J P Ratone","year":"2017","journal-title":"Ann Gastroenterol"},{"issue":"10","key":"ref10","doi-asserted-by":"crossref","first-page":"1841","DOI":"10.14309\/ajg.0000000000002239","article-title":"Evaluation of computer-aided detection during colonoscopy in the community (AI-SEE): a Multicenter randomized clinical trial","volume":"118","author":"M T Wei","year":"2023","journal-title":"Am J Gastroenterol"},{"issue":"08","key":"ref11","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1016\/S2468-1253(23)00104-8","article-title":"Effect of real-time computer-aided detection of colorectal adenoma in routine colonoscopy (COLO-GENIUS): a single-Centre randomised controlled trial","volume":"8","author":"D Karsenti","year":"2023","journal-title":"Lancet Gastroenterol Hepatol"},{"issue":"03","key":"ref12","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.gie.2018.09.028","article-title":"G-EYE colonoscopy is superior to standard colonoscopy for increasing adenoma detection rate: an international randomized controlled trial (with videos)","volume":"89","author":"H Shirin","year":"2019","journal-title":"Gastrointest Endosc"},{"issue":"03","key":"ref13","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1055\/s-0034-1391437","article-title":"Comparison of adenoma detection and miss rates between a novel balloon colonoscope and standard colonoscopy: a randomized tandem study","volume":"47","author":"Z Halpern","year":"2015","journal-title":"Endoscopy"},{"issue":"09","key":"ref14","doi-asserted-by":"crossref","first-page":"E920","DOI":"10.1055\/a-2005-6934","article-title":"Retrospective comparison of G-EYE balloon-colonoscopy with standard colonoscopy for increased adenoma detection rate and reduced polyp removal time","volume":"11","author":"R Kiesslich","year":"2023","journal-title":"Endosc Int Open"},{"issue":"03","key":"ref16","doi-asserted-by":"crossref","first-page":"458","DOI":"10.14309\/ajg.0000000000001122","article-title":"ACG clinical guidelines: colorectal cancer screening 2021","volume":"116","author":"A Shaukat","year":"2021","journal-title":"Am J Gastroenterol"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/j.gie.2008.05.057","article-title":"The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research","volume":"69","author":"E J Lai","year":"2009","journal-title":"Gastrointest Endosc"},{"issue":"03","key":"ref18","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1055\/s-0043-102569","article-title":"Colorectal polypectomy and endoscopic mucosal resection (EMR): European Society of Gastrointestinal Endoscopy (ESGE) clinical guideline","volume":"49","author":"M Ferlitsch","year":"2017","journal-title":"Endoscopy"},{"issue":"09","key":"ref19","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1055\/a-1547-2282","article-title":"Endoscopy in patients on antiplatelet or anticoagulant therapy: British Society of Gastroenterology (BSG) and European Society of Gastrointestinal Endoscopy (ESGE) guideline update","volume":"53","author":"A M Veitch","year":"2021","journal-title":"Endoscopy"},{"issue":"02","key":"ref20","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1111\/j.1572-0241.2006.00390.x","article-title":"Polyp miss rate determined by tandem colonoscopy: a systematic review","volume":"101","author":"J C van Rijn","year":"2006","journal-title":"Am J Gastroenterol"},{"issue":"04","key":"ref21","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1055\/s-2007-995618","article-title":"Miss rate for colorectal neoplastic polyps: a prospective multicenter study of back-to-back video colonoscopies","volume":"40","author":"D Heresbach","year":"2008","journal-title":"Endoscopy"},{"issue":"19","key":"ref22","doi-asserted-by":"crossref","first-page":"3535","DOI":"10.1002\/sim.2825","article-title":"A method for testing a prespecified subgroup in clinical trials","volume":"26","author":"Y Song","year":"2007","journal-title":"Stat Med"},{"issue":"06","key":"ref23","doi-asserted-by":"crossref","first-page":"1078","DOI":"10.1016\/j.gie.2021.11.038","article-title":"Novel classification for adverse events in GI endoscopy: the AGREE classification","volume":"95","author":"K J Nass","year":"2022","journal-title":"Gastrointest Endosc"},{"issue":"03","key":"ref24","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1016\/j.gie.2024.04.2905","article-title":"Quality indicators for colonoscopy","volume":"100","author":"D K Rex","year":"2024","journal-title":"Gastrointest Endosc"}],"container-title":["Endoscopy International Open"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2901-5859.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T00:47:55Z","timestamp":1784940475000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2901-5859"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,8]]},"references-count":23,"journal-issue":{"issue":"CP","published-online":{"date-parts":[[2026,1,13]]},"published-print":{"date-parts":[[2026]]}},"alternative-id":["a29015859"],"URL":"https:\/\/doi.org\/10.1055\/a-2901-5859","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["2364-3722","2196-9736"],"issn-type":[{"value":"2364-3722","type":"print"},{"value":"2196-9736","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,7,8]]},"published":{"date-parts":[[2026,7,8]]}}}