{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T23:52:14Z","timestamp":1791417134187,"version":"4.3.3"},"reference-count":25,"publisher":"Georg Thieme Verlag KG","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Knee Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Conventional intraoperative gap assessment is performed in standardized reference positions that do not replicate many functional postures patients assume during daily activities. Physiologic lateral compartment opening becomes most apparent in postures combining flexion, hip external rotation, and relative varus alignment, such as sitting cross-legged, and shoe or sock application. The figure-of-4 position reproduces this combination intraoperatively. The purpose of this study was to describe the figure-of-4 maneuver as an intraoperative positional assessment during robotic total knee arthroplasty (rTKA) and quantitatively characterize compartment behavior during its execution using standardized robotic measurements. Eighty-three consecutive primary rTKAs performed by a single surgeon were retrospectively analyzed. After bone preparation and balancing, with trial components in situ, each knee underwent conventional and figure-of-4 assessment. The VELYS standardized robotic measurement framework was used for both conditions; only limb posture differed. Compartment behavior was expressed as the medial-to-lateral gap difference (\u0394ML; medial minus lateral) in flexion and extension. Conventional and figure-of-4 \u0394ML were compared within each knee using paired t-tests and Wilcoxon signed-rank tests. Preoperative hip-knee-ankle (HKA) angle was correlated with the change in \u0394ML using Pearson and Spearman coefficients. Figure-of-4 assessment produced consistently more negative flexion \u0394ML than conventional assessment (mean difference \u2212\u20092.181\u2009mm; 95% CI: \u2212\u20092.414 to \u2212\u20091.947; p\u2009&lt;\u20090.001; Cohen's d\u2009=\u20092.039). Extension \u0394ML did not differ significantly (mean difference 0.080\u2009mm; 95% CI: \u2212\u20090.019 to 0.178; p\u2009=\u20090.113). Preoperative HKA angle did not correlate with the change in flexion \u0394ML (r\u2009=\u20090.091, p\u2009=\u20090.416) or extension \u0394ML (r\u2009=\u2009\u2212\u20090.111, p\u2009=\u20090.318). Figure-of-4 assessment consistently demonstrated greater lateral compartment opening in flexion than conventional assessment, while extension measurements remained essentially unchanged. The standardized robotic measurement framework enabled objective quantification of compartment behavior in a positional condition not evaluated during routine assessment. The maneuver characterizes behavior of the prepared knee in a posture associated with common activities of daily living and provides information complementary to conventional assessment.<\/jats:p>","DOI":"10.1055\/a-2968-6106","type":"journal-article","created":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T23:16:57Z","timestamp":1790378217000},"source":"Crossref","is-referenced-by-count":0,"title":["The Figure-of-4 Maneuver: Quantitative Characterization of Lateral Compartment Behavior During Robotic Total Knee Arthroplasty"],"prefix":"10.1055","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-3079-2416","authenticated-orcid":false,"given":"Ravi C.","family":"Vattipalli","sequence":"additional","affiliation":[{"name":"CARE Hospitals, Andhra Pradesh, India","place":["Visakhapatnam"],"department":["Department of Orthopaedics"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-6931-7202","authenticated-orcid":false,"given":"Varoon C.","family":"Palakodety","sequence":"additional","affiliation":[{"name":"CARE Hospitals, Andhra Pradesh, India","place":["Visakhapatnam"],"department":["Department of Orthopaedics"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2026,10,7]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.arth.2006.02.084","article-title":"Gap balancing in total knee arthroplasty","volume":"21","author":"J Bottros","year":"2006","journal-title":"J Arthroplasty"},{"issue":"380","key":"ref2","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1097\/00003086-200011000-00007","article-title":"Functional medial ligament balancing in total knee arthroplasty","author":"L A Whiteside","year":"2000","journal-title":"Clin Orthop Relat Res"},{"issue":"01","key":"ref3","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1007\/s11999-012-2407-3","article-title":"Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA","volume":"471","author":"E K Song","year":"2013","journal-title":"Clin Orthop Relat Res"},{"issue":"03","key":"ref4","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1302\/0301-620X.101B3.BJJ-2018-0544.R1","article-title":"Medial and lateral gap laxity differential in computer-assisted kinematic total knee arthroplasty","volume":"101-B","author":"P McEwen","year":"2019","journal-title":"Bone Joint J"},{"issue":"04","key":"ref5","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1016\/j.arth.2021.12.035","article-title":"Image-free robotic-assisted total knee arthroplasty improves implant alignment accuracy: a cadaveric study","volume":"37","author":"G W Doan","year":"2022","journal-title":"J Arthroplasty"},{"issue":"03","key":"ref6","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1055\/s-0038-1641729","article-title":"Robotic-arm assisted total knee arthroplasty demonstrated greater accuracy and precision to plan compared with manual techniques","volume":"32","author":"E L Hampp","year":"2019","journal-title":"J Knee Surg"},{"issue":"04","key":"ref7","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1002\/jor.20114","article-title":"Hip, knee, and ankle kinematics of high range of motion activities of daily living","volume":"24","author":"A Hemmerich","year":"2006","journal-title":"J Orthop Res"},{"issue":"03","key":"ref8","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1097\/00004356-200109000-00004","article-title":"Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants","volume":"24","author":"S J Mulholland","year":"2001","journal-title":"Int J Rehabil Res"},{"issue":"01","key":"ref9","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1093\/ptj\/52.1.34","article-title":"A quantitative analysis of knee motion during activities of daily living","volume":"52","author":"K N Laubenthal","year":"1972","journal-title":"Phys Ther"},{"issue":"02","key":"ref10","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/j.arth.2010.08.003","article-title":"Knee kinematics of high-flexion activities of daily living performed by male Muslims in the Middle East","volume":"26","author":"S M Acker","year":"2011","journal-title":"J Arthroplasty"},{"issue":"01","key":"ref11","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1186\/s12891-021-04369-4","article-title":"A high degree of knee flexion after TKA promotes the ability to perform high-flexion activities and patient satisfaction in Asian population","volume":"22","author":"H S Han","year":"2021","journal-title":"BMC Musculoskelet Disord"},{"issue":"07","key":"ref12","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1302\/0301-620X.89B7.19091","article-title":"The role of pain and function in determining patient satisfaction after total knee replacement","volume":"89","author":"P N Baker","year":"2007","journal-title":"J Bone Joint Surg Br"},{"issue":"11","key":"ref13","doi-asserted-by":"crossref","first-page":"3614","DOI":"10.1007\/s00167-019-05474-7","article-title":"Mid-flexion laxity in the asymptomatic native knee is predominantly present on the lateral side","volume":"27","author":"M EM Te Molder","year":"2019","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"03","key":"ref14","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1007\/s00776-006-1009-x","article-title":"Asymmetry of mediolateral laxity of the normal knee","volume":"11","author":"K Okazaki","year":"2006","journal-title":"J Orthop Sci"},{"issue":"20","key":"ref15","doi-asserted-by":"crossref","first-page":"1678","DOI":"10.2106\/JBJS.N.01256","article-title":"Native knee laxities at 0\u00b0, 45\u00b0, and 90\u00b0 of flexion and their relationship to the goal of the gap-balancing alignment method of total knee arthroplasty","volume":"97","author":"J D Roth","year":"2015","journal-title":"J Bone Joint Surg Am"},{"issue":"08","key":"ref16","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1302\/0301-620X.86B8.15246","article-title":"The flexion gap in normal knees. An MRI study","volume":"86","author":"Y Tokuhara","year":"2004","journal-title":"J Bone Joint Surg Br"},{"issue":"07","key":"ref17","doi-asserted-by":"crossref","first-page":"1695","DOI":"10.1177\/0363546503262694","article-title":"Force measurements on the fibular collateral ligament, popliteofibular ligament, and popliteus tendon to applied loads","volume":"32","author":"R F LaPrade","year":"2004","journal-title":"Am J Sports Med"},{"issue":"11","key":"ref18","doi-asserted-by":"crossref","first-page":"3426","DOI":"10.1007\/s11999-014-3865-6","article-title":"Collateral ligament laxity in knees: what is normal?","volume":"472","author":"K Deep","year":"2014","journal-title":"Clin Orthop Relat Res"},{"issue":"06","key":"ref19","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1177\/03635465030310062101","article-title":"The posterolateral attachments of the knee: a qualitative and quantitative morphologic analysis of the fibular collateral ligament, popliteus tendon, popliteofibular ligament, and lateral gastrocnemius tendon","volume":"31","author":"R F LaPrade","year":"2003","journal-title":"Am J Sports Med"},{"issue":"08","key":"ref20","doi-asserted-by":"crossref","first-page":"1189","DOI":"10.1302\/0301-620X.82B8.0821189","article-title":"Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee","volume":"82","author":"H Iwaki","year":"2000","journal-title":"J Bone Joint Surg Br"},{"issue":"05","key":"ref21","doi-asserted-by":"crossref","first-page":"1563","DOI":"10.1111\/os.12949","article-title":"Posteromedial corner release with the knee in figure-of-four position vs conventional position for varus knee arthroplasty","volume":"13","author":"Q B Ji","year":"2021","journal-title":"Orthop Surg"},{"issue":"08","key":"ref22","doi-asserted-by":"crossref","first-page":"1604","DOI":"10.1097\/CORR.0000000000002184","article-title":"Arthroplasty surgeons differ in their intraoperative soft tissue assessments: a study in human cadavers to quantify surgical decision-making in TKA","volume":"480","author":"S S Elmasry","year":"2022","journal-title":"Clin Orthop Relat Res"},{"issue":"01","key":"ref23","doi-asserted-by":"crossref","first-page":"e70107","DOI":"10.1002\/jeo2.70107","article-title":"Navigated instrumentation and ligament tensioning device enhances initial gap acquisition during total knee arthroplasty procedure: a cadaveric study","volume":"12","author":"F Boux de Casson","year":"2025","journal-title":"J Exp Orthop"},{"issue":"02","key":"ref24","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.jbiomech.2004.02.006","article-title":"The movement of the normal tibio-femoral joint","volume":"38","author":"M AR Freeman","year":"2005","journal-title":"J Biomech"},{"issue":"04","key":"ref25","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1016\/j.knee.2014.03.007","article-title":"Patient satisfaction after posterior-stabilized total knee arthroplasty: a functional specific analysis","volume":"21","author":"H Du","year":"2014","journal-title":"Knee"}],"container-title":["The Journal of Knee Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/a-2968-6106.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T23:31:51Z","timestamp":1791415911000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/a-2968-6106"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,25]]},"references-count":25,"URL":"https:\/\/doi.org\/10.1055\/a-2968-6106","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["1538-8506","1938-2480"],"issn-type":[{"value":"1538-8506","type":"print"},{"value":"1938-2480","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,9,25]]},"published":{"date-parts":[[2026,9,25]]}}}