{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T07:36:08Z","timestamp":1790840168441,"version":"4.1.0"},"reference-count":0,"publisher":"Georg Thieme Verlag KG","issue":"06","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet Comp Orthop Traumatol"],"published-print":{"date-parts":[[2018,11]]},"abstract":"<jats:p>\n            Objectives\u2003The purpose was to compare the biomechanical properties of a 1.5\u2009mm locking compression plate (1.5 LCP) to the 1.5\u2009mm straight plate (1.5 P), 1.5\u2009mm straight plate stacked (1.5 PSt) and 2.0\u2009mm straight plate (2.0 P) in compression and torsion. We hypothesized that biomechanical properties of the 1.5 LCP would be equivalent to properties of the 1.5 P and would represent an alternative for the treatment of radial fractures in miniature breed dogs in which those plates would be used.<\/jats:p><jats:p>\n            Materials and Methods\u2003A 1\u2009mm fracture gap model was created with a bone surrogate stabilized with a six-hole plate. Sixteen constructs were built for each of the four plate configurations. Eight constructs from each group were tested in compression to failure and eight constructs were tested in torsion to failure.<\/jats:p><jats:p>\n            Results\u2003In compression testing, the 1.5 LCP was stiffer than the 1.5 P, and had similar stiffness than the 1.5 PSt and the 2.0 P. The load at yield of the 1.5 LCP was slightly lower than the 1.5 P. In torsion, the 1.5 LCP and 1.5 P had similar stiffness, but 1.5 LCP was slightly stronger than 1.5 P. The 1.5 PSt and 2.0 P were overall superior to the 1.5 LCP but only marginally so for the 1.5 PSt.<\/jats:p><jats:p>\n            Clinical Relevance\u2003The 1.5 LCP can be considered biomechanically equivalent to the 1.5 P under the present experimental conditions. The use of the 1.5 LCP can be considered as an option for radial fracture repair in dogs in which a 1.5 P would have otherwise been used. The use of a locking plate to improve overall success rate, in these fractures, remains to be confirmed clinically.<\/jats:p>","DOI":"10.1055\/s-0038-1668084","type":"journal-article","created":{"date-parts":[[2018,10,24]],"date-time":"2018-10-24T22:53:51Z","timestamp":1540421631000},"page":"438-444","source":"Crossref","is-referenced-by-count":10,"title":["Biomechanical Properties of the 1.5\u2009mm Locking Compression Plate: Comparison with the 1.5 and 2.0\u2009mm Straight Plates in Compression and Torsion"],"prefix":"10.1055","volume":"31","author":[{"given":"Noel","family":"Moens","sequence":"first","affiliation":[{"name":"Department of Clinical Studies, University of Guelph, Ontario Veterinary College, Guelph, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Runciman","sequence":"first","affiliation":[{"name":"Department of Engineering, University of Guelph, Guelph, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom","family":"Gibson","sequence":"first","affiliation":[{"name":"Department of Clinical Studies, University of Guelph, Ontario Veterinary College, Guelph, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gwyneth","family":"Watrous","sequence":"additional","affiliation":[{"name":"Department of Clinical Studies, University of Guelph, Ontario Veterinary College, Guelph, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2018,10,24]]},"container-title":["Veterinary and Comparative Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0038-1668084.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,1,2]],"date-time":"2019-01-02T15:05:04Z","timestamp":1546441504000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0038-1668084"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,24]]},"references-count":0,"journal-issue":{"issue":"06","published-online":{"date-parts":[[2018,11,12]]},"published-print":{"date-parts":[[2018,11]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0038-1668084","relation":{},"ISSN":["0932-0814","2567-6911"],"issn-type":[{"value":"0932-0814","type":"print"},{"value":"2567-6911","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,24]]}}}