{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T14:01:51Z","timestamp":1773842511665,"version":"3.50.1"},"reference-count":0,"publisher":"Georg Thieme Verlag KG","issue":"01","license":[{"start":{"date-parts":[[2018,11,29]],"date-time":"2018-11-29T00:00:00Z","timestamp":1543449600000},"content-version":"vor","delay-in-days":332,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["THORAC CARDIOV SURG Reports"],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:p>\n            Background\u2003Coxiella burnetii is a gram-negative bacterium assigned to the family of Rickettsiaceae. Less than 1% of Q-fever infection leads to infective endocarditis (IE). Cases of reported pulmonary valve (PV) prosthesis endocarditis are scarce.<\/jats:p><jats:p>\n            Case Description\u2003A patient with a PV prosthesis endocarditis caused by Coxiella burnetii was seeking asylum in Germany. Prosthesis replacement was performed. All obtained blood cultures showed no growth as well as microbiological cultures of the prosthetic valve tissue. A polymerase chain reaction analysis on the explanted prosthesis detected DNA of Coxiella spp.<\/jats:p><jats:p>\n            Conclusion\u2003Diagnosing IE caused by Coxiella burnetii requires an interdisciplinary effort from both clinicians and microbiologists.<\/jats:p>","DOI":"10.1055\/s-0038-1675841","type":"journal-article","created":{"date-parts":[[2018,11,29]],"date-time":"2018-11-29T23:42:20Z","timestamp":1543534940000},"page":"e47-e49","source":"Crossref","is-referenced-by-count":2,"title":["Pulmonary Valve Prosthesis Endocarditis Caused By Coxiella burnetii"],"prefix":"10.1055","volume":"07","author":[{"given":"Jamila","family":"Kremer","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Universitatsklinikum Heidelberg Chirurgische Klinik, Heidelberg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nico","family":"Mutters","sequence":"additional","affiliation":[{"name":"Center of Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany"},{"name":"Institute for Infection Prevention and Hospital Epidemiology, Medical Centre\u2014University of Freiburg, Faculty of Medicine, Freiburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"Karck","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Universitatsklinikum Heidelberg Chirurgische Klinik, Heidelberg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katharina","family":"Last","sequence":"additional","affiliation":[{"name":"Center of Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2018,11,29]]},"container-title":["The Thoracic and Cardiovascular Surgeon Reports"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0038-1675841.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,6]],"date-time":"2019-05-06T20:10:46Z","timestamp":1557173446000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0038-1675841"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1]]},"references-count":0,"journal-issue":{"issue":"01","published-online":{"date-parts":[[2018,2,20]]},"published-print":{"date-parts":[[2018,1]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0038-1675841","relation":{},"ISSN":["2194-7635","2194-7643"],"issn-type":[{"value":"2194-7635","type":"print"},{"value":"2194-7643","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1]]}}}