{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:36:40Z","timestamp":1740148600632,"version":"3.37.3"},"reference-count":0,"publisher":"Georg Thieme Verlag KG","issue":"04","license":[{"start":{"date-parts":[[2019,8,20]],"date-time":"2019-08-20T00:00:00Z","timestamp":1566259200000},"content-version":"vor","delay-in-days":50,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rev Bras Ortop"],"published-print":{"date-parts":[[2019,7]]},"abstract":"<jats:title>Resumo<\/jats:title><jats:p>\n          Objetivo\u2003Avaliar, por meio de ensaio biomec\u00e2nico, a resist\u00eancia e a energia necess\u00e1ria para ocorr\u00eancia de fratura do f\u00eamur proximal em osso sint\u00e9tico ap\u00f3s retirada de parafusos canulados em forma de tri\u00e2ngulo invertido e comparar os resultados obtidos com t\u00e9cnica de refor\u00e7o utilizando polimetilmetacrilato (PMMA).<\/jats:p><jats:p>\n          M\u00e9todos\u2003Foram utilizados 20 ossos sint\u00e9ticos: 10 unidades para o grupo controle; 5 o grupo teste sem refor\u00e7o, sem preenchimento ap\u00f3s a retirada dos parafusos canulados, e 5 o para grupo teste com refor\u00e7o com PMMA. A an\u00e1lise biomec\u00e2nica foi realizada simulando queda sobre o grande troc\u00e2nter utilizando m\u00e1quina servo-hidr\u00e1ulica.<\/jats:p><jats:p>\n          Resultados\u2003Todos os corpos de prova dos grupos controle e sem cimento apresentaram fratura baso-cervical. No grupo teste com preechimento, tr\u00eas corpos de prova apresentaram fratura baso-cervical, enquanto que dois deles apresentaram fratura na parte pr\u00f3xima ao ponto de fixa\u00e7\u00e3o no dispositivo (regi\u00e3o diafis\u00e1ria do f\u00eamur), sendo um deles associado a fratura do colo femoral. Foi utilizada uma m\u00e9dia de 8.2\u2009ml de polimetilmetacrilato no preenchimento dos tr\u00eas pertuitos do grupo com preenchimento. Segundo a an\u00e1lise de vari\u00e2ncia (ANOVA, na sigla em ingl\u00eas) para um fator e o teste de compara\u00e7\u00f5es m\u00faltiplas de Tukey, ao n\u00edvel de 5%, o grupo com cimento apresentou diferen\u00e7a significativa em rela\u00e7\u00e3o aos outros grupos em todos os par\u00e2metros.<\/jats:p><jats:p>\n          Conclus\u00e3o\u2003A simples retirada dos parafusos canulados n\u00e3o apresentou redu\u00e7\u00e3o significativa da carga m\u00e1xima e da energia necess\u00e1rias para a ocorr\u00eancia de fratura; por\u00e9m, o refor\u00e7o do f\u00eamur proximal com polimetilmetacrilato aumentou significativamente esses par\u00e2metros, causando mudan\u00e7as no padr\u00e3o fratur\u00e1rio.<\/jats:p>","DOI":"10.1055\/s-0039-1693046","type":"journal-article","created":{"date-parts":[[2019,8,26]],"date-time":"2019-08-26T08:12:27Z","timestamp":1566807147000},"page":"416-421","source":"Crossref","is-referenced-by-count":3,"title":["Ensaio biomec\u00e2nico ap\u00f3s retirada de parafusos canulados do f\u00eamur proximal (an\u00e1lise in vitro)"],"prefix":"10.1055","volume":"54","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6555-8193","authenticated-orcid":false,"given":"Anderson","family":"Freitas","sequence":"additional","affiliation":[{"name":"Instituto de Pesquisa e Ensino do Hospital Ortop\u00e9dico e Medicina Especializada (IPE-HOME-DF), Bras\u00edlia, DF, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucas S.","family":"Ramos","sequence":"additional","affiliation":[{"name":"Servi\u00e7o de Ortopedia e Traumatologia, Hospital Regional do Gama (HRG-DF), Bras\u00edlia, DF, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"\u00c9rgon LAB","family":"Dantas","sequence":"additional","affiliation":[{"name":"Servi\u00e7o de Ortopedia e Traumatologia, Hospital Regional do Gama (HRG-DF), Bras\u00edlia, DF, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vincenzo","family":"Giordano Neto","sequence":"additional","affiliation":[{"name":"Servi\u00e7o de Ortopedia e Traumatologia, Hospital Municipal Miguel Couto (HMMC-RJ), Rio de Janeiro, RJ, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick F.","family":"Godinho","sequence":"additional","affiliation":[{"name":"Instituto de Pesquisa e Ensino do Hospital Ortop\u00e9dico e Medicina Especializada (IPE-HOME-DF), Bras\u00edlia, DF, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ant\u00f4nio C.","family":"Shimano","sequence":"additional","affiliation":[{"name":"Departamento de Biomec\u00e2nica, Medicina e Reabilita\u00e7\u00e3o do Aparelho Locomotor, Faculdade de Medicina de Ribeir\u00e3o Preto, Universidade de S\u00e3o Paulo (USP-RP), Riberi\u00e3o Preto, SP, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2019,8,20]]},"container-title":["Revista Brasileira de Ortopedia"],"original-title":[],"language":"pt","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0039-1693046.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,26]],"date-time":"2019-08-26T08:12:33Z","timestamp":1566807153000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0039-1693046"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7]]},"references-count":0,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2019,8,20]]},"published-print":{"date-parts":[[2019,7]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0039-1693046","relation":{},"ISSN":["0102-3616","1982-4378"],"issn-type":[{"type":"print","value":"0102-3616"},{"type":"electronic","value":"1982-4378"}],"subject":[],"published":{"date-parts":[[2019,7]]}}}