{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T05:53:42Z","timestamp":1785390822971,"version":"3.55.0"},"reference-count":28,"publisher":"Georg Thieme Verlag KG","issue":"05","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Semin Musculoskelet Radiol"],"published-print":{"date-parts":[[2020,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>With the introduction of cone beam computed tomography (CBCT) into dentistry in the 1990s, radiologists have become more frequently involved in dental implant planning. This article describes the information that should be included in a radiology report to achieve a successful implantation. The justification to use CBCT during the preoperative planning phase is based on the need to evaluate patient-specific anatomy in detail (general condition of the jaw, bone quantity, and bone quality), the application of more advanced surgical techniques (maxillary sinus augmentation procedure, zygomatic implants), and the integrated presurgical planning and virtual patient approach. Postoperatively, CBCT is used when implant retrieval is anticipated and two-dimensional radiographs have not provided sufficient information, for evaluation of graft healing, or to assess complications, mostly related to neurovascular trauma.<\/jats:p>","DOI":"10.1055\/s-0040-1701496","type":"journal-article","created":{"date-parts":[[2020,10,9]],"date-time":"2020-10-09T22:31:11Z","timestamp":1602282671000},"page":"499-509","source":"Crossref","is-referenced-by-count":6,"title":["Cone Beam Computed Tomography Imaging in Dental Implants: A Primer for Clinical Radiologists"],"prefix":"10.1055","volume":"24","author":[{"given":"Anja","family":"Bernaerts","sequence":"additional","affiliation":[{"name":"Department of Radiology, GZA Hospitals, Antwerp, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lieven","family":"Barbier","sequence":"additional","affiliation":[{"name":"Training Center for Dental Students of the KU Leuven, AZ Sint-Jan Brugge-Oostende AV, Bruges, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johan","family":"Abeloos","sequence":"additional","affiliation":[{"name":"Department of Maxillo-Facial Surgery, AZ Sint-Jan Brugge-Oostende AV, Bruges, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom","family":"De Backer","sequence":"additional","affiliation":[{"name":"Department of Maxillo-Facial Surgery, AZ Sint-Jan Brugge-Oostende AV, Bruges, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frederik","family":"Bosmans","sequence":"additional","affiliation":[{"name":"Department of Radiology, Antwerp University Hospital, Edegem, Belgium"},{"name":"Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Filip M.","family":"Vanhoenacker","sequence":"additional","affiliation":[{"name":"Department of Radiology, Antwerp University Hospital, Edegem, Belgium"},{"name":"Department of Radiology, AZ Sint-Maarten, Mechelen, Belgium"},{"name":"Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Casselman","sequence":"additional","affiliation":[{"name":"Department of Radiology, GZA Hospitals, Antwerp, Belgium"},{"name":"Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium"},{"name":"Department of Radiology, AZ Sint-Jan Brugge-Oostende AV, Bruges, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2020,10,9]]},"reference":[{"issue":"01","key":"ref1","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1186\/s12903-018-0523-5","article-title":"Cone beam computed tomography in implant dentistry: recommendations for clinical use","volume":"18","author":"R Jacobs","year":"2018","journal-title":"BMC Oral Health"},{"issue":"02","key":"ref2","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1148\/radiology.219.2.r01ma33334","article-title":"Dental CT imaging: a look at the jaw","volume":"219","author":"J J Abrahams","year":"2001","journal-title":"Radiology"},{"issue":"01","key":"ref3","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.rcl.2017.08.010","article-title":"Radiology of implant dentistry","volume":"56","author":"A A Al-Ekrish","year":"2018","journal-title":"Radiol Clin North Am"},{"issue":"01","key":"ref4","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1111\/prd.12161","article-title":"Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research","volume":"73","author":"M M Bornstein","year":"2017","journal-title":"Periodontol 2000"},{"issue":"01","key":"ref5","first-page":"32","article-title":"The role of dental CT imaging in dental implantology","volume":"89","author":"A Bernaerts","year":"2006","journal-title":"JBR-BTR"},{"issue":"01","key":"ref6","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.cden.2014.09.003","article-title":"Use of cone-beam computed tomography in early detection of implant failure","volume":"59","author":"J F Yepes","year":"2015","journal-title":"Dent Clin North Am"},{"issue":"10","key":"ref7","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1902\/jop.2017.160548","article-title":"The use of cone-beam computed tomography in management of patients requiring dental implants: an American Academy of Periodontology best evidence review","volume":"88","author":"H F Rios","year":"2017","journal-title":"J Periodontol"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1046\/j.0906-6713.2002.03311.x","article-title":"An infected jawbone site compromising successful osseointegration","volume":"33","author":"M Quirynen","year":"2003","journal-title":"Periodontol 2000"},{"key":"ref9","volume-title":"Specialty Imaging: Dental Implants","author":"D Tamimi","year":"2014"},{"issue":"07","key":"ref10","doi-asserted-by":"crossref","first-page":"1426","DOI":"10.1016\/j.joms.2008.01.027","article-title":"Anatomical and surgical findings and complications in 100 consecutive maxillary sinus floor elevation procedures","volume":"66","author":"S A Zijderveld","year":"2008","journal-title":"J Oral Maxillofac Surg"},{"issue":"03","key":"ref11","first-page":"115","article-title":"Sinus presurgical evaluation: a literature review and a new classification proposal","volume":"66","author":"L Tavelli","year":"2017","journal-title":"Minerva Stomatol"},{"issue":"07","key":"ref12","doi-asserted-by":"crossref","first-page":"1975","DOI":"10.1148\/rg.307105026","article-title":"Dental multisection CT for the placement of oral implants: technique and applications","volume":"30","author":"J A Saavedra-Abril","year":"2010","journal-title":"Radiographics"},{"issue":"04","key":"ref13","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1016\/S0901-5027(88)80047-X","article-title":"A classification of the edentulous jaws","volume":"17","author":"J I Cawood","year":"1988","journal-title":"Int J Oral Maxillofac Surg"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1186\/s12903-015-0055-1","article-title":"Anterior maxilla alveolar ridge dimension and morphology measurement by cone beam computerized tomography (CBCT) for immediate implant treatment planning","volume":"15","author":"W Zhang","year":"2015","journal-title":"BMC Oral Health"},{"issue":"02","key":"ref15","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.jcms.2014.11.018","article-title":"Lingual concavities in the mandible: a morphological study using cross-sectional analysis determined by CBCT","volume":"43","author":"H J Nickenig","year":"2015","journal-title":"J Craniomaxillofac Surg"},{"issue":"01","key":"ref16","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1259\/dmfr\/14140281","article-title":"Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography","volume":"37","author":"A Suomalainen","year":"2008","journal-title":"Dentomaxillofac Radiol"},{"issue":"01","key":"ref17","doi-asserted-by":"crossref","first-page":"20140238","DOI":"10.1259\/dmfr.20140238","article-title":"CBCT-based bone quality assessment: are Hounsfield units applicable?","volume":"44","author":"R Pauwels","year":"2015","journal-title":"Dentomaxillofac Radiol"},{"key":"ref18","first-page":"199","volume-title":"Patient selection and preparation","author":"U Lekholm","year":"1985"},{"issue":"01","key":"ref19","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/s40729-019-0158-6","article-title":"Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants","volume":"5","author":"D F Triches","year":"2019","journal-title":"Int J Implant Dent"},{"issue":"03","key":"ref20","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1016\/j.cden.2014.04.002","article-title":"Presurgical implant-site assessment and restoratively driven digital planning","volume":"58","author":"M D Scherer","year":"2014","journal-title":"Dent Clin North Am"},{"issue":"05","key":"ref21","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1111\/j.1600-0501.2010.02029.x","article-title":"Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard","volume":"22","author":"LdosS Corpas","year":"2011","journal-title":"Clin Oral Implants Res"},{"issue":"11","key":"ref22","doi-asserted-by":"crossref","first-page":"708","DOI":"10.6061\/clinics\/2017(11)10","article-title":"Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study","volume":"72","author":"N Silveira-Neto","year":"2017","journal-title":"Clinics (S\u00e3o Paulo)"},{"issue":"11","key":"ref23","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1111\/jcpe.13183","article-title":"Inaccuracy of buccal bone thickness estimation on cone-beam CT due to implant blooming: an ex-vivo study","volume":"46","author":"T Vanderstuyft","year":"2019","journal-title":"J Clin Periodontol"},{"issue":"05","key":"ref24","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1111\/clr.13143","article-title":"Diagnostic performance of cone beam computed tomography in assessing peri-implant bone loss: a systematic review","volume":"29","author":"G Pelekos","year":"2018","journal-title":"Clin Oral Implants Res"},{"issue":"04","key":"ref25","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1111\/cid.12791","article-title":"Morphology and severity of peri-implantitis bone defects","volume":"21","author":"A Monje","year":"2019","journal-title":"Clin Implant Dent Relat Res"},{"issue":"04","key":"ref26","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1563\/AAID-JOI-D-11-00234","article-title":"Osseointegration of dental implants and osteonecrosis of the jaw in patients treated with bisphosphonate therapy: a systematic review","volume":"39","author":"G K Chadha","year":"2013","journal-title":"J Oral Implantol"},{"issue":"04","key":"ref27","doi-asserted-by":"crossref","first-page":"20170323","DOI":"10.1259\/dmfr.20170323","article-title":"CT imaging features of antiresorptive agent-related osteonecrosis of the jaw\/medication-related osteonecrosis of the jaw","volume":"47","author":"A Baba","year":"2018","journal-title":"Dentomaxillofac Radiol"},{"issue":"05","key":"ref28","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1111\/cid.12511","article-title":"Incidental findings of implant complications on postimplantation CBCTs: A cross-sectional study","volume":"19","author":"D Clark","year":"2017","journal-title":"Clin Implant Dent Relat Res"}],"container-title":["Seminars in Musculoskeletal Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0040-1701496.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T12:38:41Z","timestamp":1696855121000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0040-1701496"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10]]},"references-count":28,"journal-issue":{"issue":"05","published-online":{"date-parts":[[2020,10,9]]},"published-print":{"date-parts":[[2020,10]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0040-1701496","relation":{},"ISSN":["1089-7860","1098-898X"],"issn-type":[{"value":"1089-7860","type":"print"},{"value":"1098-898X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10]]}}}