{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:26:08Z","timestamp":1740147968916,"version":"3.37.3"},"reference-count":15,"publisher":"Georg Thieme Verlag KG","issue":"04","funder":[{"DOI":"10.13039\/501100004410","name":"Scientific and Technological Research Council of Turkey","doi-asserted-by":"crossref","award":["T\u00dcB\u0130TAK\/TOVAG-114O726"],"award-info":[{"award-number":["T\u00dcB\u0130TAK\/TOVAG-114O726"]}],"id":[{"id":"10.13039\/501100004410","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet Comp Orthop Traumatol"],"published-print":{"date-parts":[[2020,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Objective\u2003The aim of this study was to investigate the applicability of computer-assisted hexapod fixators in dogs and to consider the advantages and disadvantages during implementation.<\/jats:p><jats:p>\n          Materials and Methods\u2003This was a prospective study. The study material consisted of 11 deformed extremities of 6 dogs. The correction plans were defined according to multiple extremity radiographs of the dog and the clinical evaluation of deformities. All measurements were uploaded to Click2Correct software program. Latent, correction and consolidation periods of each dog were recorded. The hexapod external fixators were removed after completion of the correction.<\/jats:p><jats:p>\n          Results\u2003Data were adapted to the radiographic navigation software to be used during operation and postoperative period. The latent period ranged from 3 to 20 days, the correction period ranged from 7 to 20 days and the consolidation period ranged from 39 to 81 days. It was concluded that special fixators can be used in dogs with complex antebrachial deformities.<\/jats:p><jats:p>\n          Clinical significance\u2003The ability to perform six axes correction at the same time has a considerable advantage, especially in dogs with complex antebrachial deformities. It is practical to use this fixation system in dogs with antebrachial deformities.<\/jats:p>","DOI":"10.1055\/s-0040-1701654","type":"journal-article","created":{"date-parts":[[2020,5,12]],"date-time":"2020-05-12T23:04:07Z","timestamp":1589324647000},"page":"227-234","source":"Crossref","is-referenced-by-count":0,"title":["Antebrachial Angular Deformities Using Computer-Assisted Hexapod External Fixator Systems in Dogs"],"prefix":"10.1055","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2232-6349","authenticated-orcid":false,"given":"\u00d6zlem","family":"\u015eeng\u00f6z \u015eirin","sequence":"additional","affiliation":[{"name":"Surgery Department, Faculty of Veterinary Medicine, Mehmet Akif Ersoy University, Burdur, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bruno","family":"Peirone","sequence":"additional","affiliation":[{"name":"Department of Veterinary Sciences, University of Turin, Turin, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lisa Adele","family":"Piras","sequence":"additional","affiliation":[{"name":"Department of Veterinary Sciences, University of Turin, Turin, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hasan","family":"Bilgili","sequence":"additional","affiliation":[{"name":"Surgery Department, Faculty of Veterinary Medicine, Ankara University, Ankara, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2020,5,12]]},"reference":[{"key":"ref1","first-page":"580","volume-title":"Canine angular limb deformities","author":"D Marcellin-Little","year":"2010"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1055\/s-0038-1633097","article-title":"Incidence of canine appendicular musculoskeletal disorders in 16 veterinary teaching hospitals from 1980 through 1989","volume":"7","author":"J A Johnson","year":"1994","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"02","key":"ref3","first-page":"118","article-title":"Initial clinical experience with the IMEX\u2122 circular external skeletal fixation system. Part II: use in bone lengthening and correction of angular and rotational deformities","volume":"12","author":"D D Lewis","year":"1999","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"03","key":"ref4","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1111\/j.1532-950X.1998.tb00122.x","article-title":"Hinged Ilizarov external fixation for correction of antebrachial deformities","volume":"27","author":"D J Marcellin-Little","year":"1998","journal-title":"Vet Surg"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1111\/j.1532-950X.1981.tb00644.x","article-title":"Asyncronous growth of the canine radius and ulna: surgical correction following experimental premature closure of the distal radial physis","volume":"10","author":"N C Olson","year":"1981","journal-title":"Vet Surg"},{"issue":"06","key":"ref6","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1097\/01.bpb.0000228380.27239.8a","article-title":"Correction of deformities in children using the Taylor spatial frame","volume":"15","author":"M Eidelman","year":"2006","journal-title":"J Pediatr Orthop B"},{"key":"ref7","first-page":"99","volume-title":"Osteotomy concepts and frontal plane realignment","author":"D Paley","year":"2002"},{"issue":"02","key":"ref8","doi-asserted-by":"crossref","first-page":"35","DOI":"10.5704\/MOJ.1407.012","article-title":"A biomechanical comparison between Taylor\u2019s spatial frame and Ilizarov external fixator","volume":"8","author":"B Tan","year":"2014","journal-title":"Malays Orthop J"},{"issue":"11","key":"ref9","doi-asserted-by":"crossref","first-page":"2247","DOI":"10.1007\/s00264-013-2116-x","article-title":"Comparative clinical study on deformity correction accuracy of different external fixators","volume":"37","author":"I Eren","year":"2013","journal-title":"Int Orthop"},{"volume-title":"Operative principles of Ilizarov: Fracture, Treatment, Nonunion, Osteomyelitis, Lengthening Deformity Correction. 1st ed","year":"1991","author":"A Maiocchi","key":"ref10"},{"issue":"07","key":"ref11","first-page":"723","article-title":"Descriptive report of antebrachial growth deformity correction in 17 dogs from 1999 to 2007, using hybrid linear-circular external fixator constructs","volume":"50","author":"C W Sereda","year":"2009","journal-title":"Can Vet J"},{"key":"ref12","first-page":"950","volume-title":"Ilizarov Technique. Techniques of Fracture Fixation","author":"A S Lesser","year":"1998"},{"issue":"11","key":"ref13","first-page":"10","article-title":"Hypertrophic osteodystrophy in dogs. Standards of Care","volume":"9","author":"B Austin","year":"2007","journal-title":"Emergency and Critical Care Medicine"},{"issue":"01","key":"ref14","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1111\/j.1532-950X.2005.00114.x","article-title":"Principles of uniapical and biapical radial deformity correction using dome osteotomies and the center of rotation of angulation methodology in dogs","volume":"35","author":"D B Fox","year":"2006","journal-title":"Vet Surg"},{"issue":"03","key":"ref15","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1055\/s-0039-1678701","article-title":"Computer-assisted surgery using 3D printed saw guides for acute correction of antebrachial angular limb deformities in dogs","volume":"32","author":"A J Worth","year":"2019","journal-title":"Vet Comp Orthop Traumatol"}],"container-title":["Veterinary and Comparative Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0040-1701654.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,21]],"date-time":"2021-10-21T16:31:56Z","timestamp":1634833916000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0040-1701654"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,12]]},"references-count":15,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2020,7,20]]},"published-print":{"date-parts":[[2020,7]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0040-1701654","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0932-0814","2567-6911"],"issn-type":[{"type":"print","value":"0932-0814"},{"type":"electronic","value":"2567-6911"}],"subject":[],"published":{"date-parts":[[2020,5,12]]}}}