{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T04:14:37Z","timestamp":1777004077044,"version":"3.51.4"},"reference-count":35,"publisher":"Georg Thieme Verlag KG","issue":"05","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet Comp Orthop Traumatol"],"published-print":{"date-parts":[[2020,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Objective\u2003The aim of this study was to report outcomes in dogs with periprosthetic femoral fractures associated with a press-fit cementless femoral total hip replacement implant.<\/jats:p><jats:p>\n          Materials and Methods\u2003Electronic medical records and digital radiographs were used to identify dogs with periprosthetic femoral fractures associated with press-fit cementless total hip replacement. Data collected included signalment, weight, time of fracture, cause of fracture, presence of intra-operative fissure, fracture type, repair technique, and clinical and radiographic outcomes. Long-term patient outcome was assessed by communication with owners or referring veterinarians.<\/jats:p><jats:p>\n          Results\u2003Twenty-eight dogs with femoral fracture repair associated with cementless press-fit total hip replacement were identified. Eight of the fractures occurred intraoperatively and 20 occurred at a median of 2 days postoperatively. An oblique or spiral configuration was noted in 19 cases and 15 occurred at the distal end of the femoral stem (type B), with thirteen type B1, one type B2 and one type B3 fractures. Fractures were repaired with non-locking (18\/28) or locking-plate fixation (10\/28). Cerclage wire was applied around the plate and proximal bone segment in 17\/28 dogs. Major complications occurred in 7\/28 cases (five deep infection, two mechanical failures). Bone healing was noted in 21\/23 cases, for which follow-up radiographic interpretation was available. Return to function was complete in 17 cases, acceptable in 8 cases and unacceptable in 3 cases.<\/jats:p><jats:p>\n          Conclusions\u2003While cementless total hip replacement periprosthetic femoral fractures can be successfully repaired with lateral plate fixation, the risk of infection appears to be high.<\/jats:p>","DOI":"10.1055\/s-0040-1709486","type":"journal-article","created":{"date-parts":[[2020,5,1]],"date-time":"2020-05-01T00:10:17Z","timestamp":1588291817000},"page":"370-376","source":"Crossref","is-referenced-by-count":9,"title":["Treatment Outcomes for Periprosthetic Femoral Fractures in Cementless Press-Fit Total Hip Replacement"],"prefix":"10.1055","volume":"33","author":[{"given":"Isobel C.","family":"Monotti","sequence":"additional","affiliation":[{"name":"Small Animal Surgery Department, The Animal Hospital at Murdoch University, Perth, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher A.","family":"Preston","sequence":"additional","affiliation":[{"name":"Pet Emergency and Specialist Centre, Melbourne, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Scott W.","family":"Kidd","sequence":"additional","affiliation":[{"name":"Sierra Veterinary Specialist and Emergency Centre, Reno, Nevada, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2020,4,30]]},"reference":[{"issue":"05","key":"ref1","doi-asserted-by":"crossref","first-page":"402","DOI":"10.3415\/VCOT-15-07-0116","article-title":"Complications of porous-coated press-fit cementless total hip replacement in dogs","volume":"29","author":"S W Kidd","year":"2016","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"02","key":"ref2","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1111\/j.1532-950X.2004.04024.x","article-title":"Femur fractures associated with canine total hip replacement","volume":"33","author":"W D Liska","year":"2004","journal-title":"Vet Surg"},{"issue":"06","key":"ref3","first-page":"688","article-title":"Risk factors for femoral fracture after canine press-fit cementless total hip arthroplasty","volume":"39","author":"S M Ganz","year":"2010","journal-title":"Vet Surg"},{"issue":"01","key":"ref4","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1111\/j.1532-950X.2011.00870.x","article-title":"String-of-pearls locking plate and cerclage wire stabilization of periprosthetic femoral fractures after total hip replacement in six dogs","volume":"41","author":"N Fitzpatrick","year":"2012","journal-title":"Vet Surg"},{"issue":"01","key":"ref5","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1136\/vr.104036","article-title":"Evaluation of variables influencing success and complication rates in canine total hip replacement: results from the British Veterinary Orthopaedic Association Canine Hip Registry (collation of data: 2010-2012)","volume":"181","author":"E R Henderson","year":"2017","journal-title":"Vet Rec"},{"issue":"06","key":"ref6","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1111\/vsu.12666","article-title":"Effect of stem sizing and position on short-term complications with canine press fit cementless total hip arthroplasty","volume":"46","author":"S Townsend","year":"2017","journal-title":"Vet Surg"},{"issue":"420","key":"ref7","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1097\/00003086-200403000-00012","article-title":"Periprosthetic fractures evaluation and treatment","author":"B A Masri","year":"2004","journal-title":"Clin Orthop Relat Res"},{"issue":"S 02","key":"ref8","doi-asserted-by":"crossref","first-page":"S45","DOI":"10.1016\/j.injury.2019.01.044","article-title":"Periprosthetic femoral fractures after total hip arthroplasty: an algorithm of treatment","volume":"50","author":"V Pavone","year":"2019","journal-title":"Injury"},{"issue":"07","key":"ref9","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1302\/0301-620X.101B7.BJJ-2018-1422.R1","article-title":"A calcar collar is protective against early periprosthetic femoral fracture around cementless femoral components in primary total hip arthroplasty: a registry study with biomechanical validation","volume":"101-B","author":"J N Lamb","year":"2019","journal-title":"Bone Joint J"},{"key":"ref10","first-page":"293","article-title":"Fractures of the femur after hip replacement","volume":"44","author":"C P Duncan","year":"1995","journal-title":"Instr Course Lect"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"S277","DOI":"10.1016\/j.arth.2019.02.062","article-title":"Reliability and validity of the Vancouver classification in periprosthetic fractures around cementless femoral stems","volume":"34","author":"S Lee","year":"2019","journal-title":"J Arthroplasty"},{"issue":"61","key":"ref12","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.clinbiomech.2018.12.001","article-title":"Periprosthetic fracture fixation of the femur following total hip arthroplasty: a review of biomechanical testing - Part II","volume":"61","author":"K Wang","year":"2019","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"04","key":"ref13","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1054\/arth.2000.4339","article-title":"Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques","volume":"15","author":"M G Dennis","year":"2000","journal-title":"J Arthroplasty"},{"issue":"06","key":"ref14","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/S0883-5403(96)80010-6","article-title":"Surgical management of intra- and postoperative fractures of the femur about the tip of the stem in total hip arthroplasty","volume":"11","author":"H Schmotzer","year":"1996","journal-title":"J Arthroplasty"},{"issue":"01","key":"ref15","first-page":"68","article-title":"Total hip arthroplasty periprosthetic femoral fractures: a review of classification and current treatment","volume":"71","author":"R Schwarzkopf","year":"2013","journal-title":"Bull Hosp Jt Dis (2013)"},{"issue":"S 02","key":"ref16","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.arth.2004.06.008","article-title":"Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years","volume":"19","author":"K R Berend","year":"2004","journal-title":"J Arthroplasty"},{"issue":"03","key":"ref17","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1111\/vsu.13185","article-title":"Use of a cerclage cable-plate system to stabilize a periprosthetic femoral fracture after total hip replacement in a dog","volume":"48","author":"J L Carvajal","year":"2019","journal-title":"Vet Surg"},{"issue":"08","key":"ref18","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1111\/j.1532-950X.2010.00763.x","article-title":"Proposed definitions and criteria for reporting time frame, outcome, and complications for clinical orthopedic studies in veterinary medicine","volume":"39","author":"J L Cook","year":"2010","journal-title":"Vet Surg"},{"key":"ref19","volume-title":"Piermattei's Atlas of Surgical Approaches to the Bones and Joint of the Dog and Cat. 5th ed","author":"K A Johnson","year":"2014"},{"issue":"06","key":"ref20","doi-asserted-by":"crossref","first-page":"409","DOI":"10.3415\/VCOT-15-03-0044","article-title":"Variability associated with assessing changes in position of a canine uncemented femoral stem prosthesis","volume":"28","author":"H M Korani","year":"2015","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"07","key":"ref21","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1111\/vsu.12353","article-title":"Use of an electron beam melting manufactured titanium collared cementless femoral stem to resist subsidence after canine total hip replacement","volume":"44","author":"W D Liska","year":"2015","journal-title":"Vet Surg"},{"issue":"09","key":"ref22","doi-asserted-by":"crossref","first-page":"65","DOI":"10.21037\/aoj.2018.07.03","article-title":"Management of peri-prosthetic fractures around total hip arthroplasty: a contemporary review of surgical options","volume":"3","author":"D Davenport","year":"2018","journal-title":"Ann Joint"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"931537","DOI":"10.1155\/2014\/931537","article-title":"Greater trochanteric fixation using a cable system for partial hip arthroplasty: a clinical and finite element analysis","volume":"2014","author":"F Ozan","year":"2014","journal-title":"BioMed Res Int"},{"issue":"04","key":"ref25","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1111\/j.1532-950X.1995.tb01340.x","article-title":"The effects of implant orientation, canal fill, and implant fit on femoral strain patterns and implant stability during catastrophic testing of a canine cementless femoral prosthesis","volume":"24","author":"R T Pernell","year":"1995","journal-title":"Vet Surg"},{"issue":"04","key":"ref26","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1016\/S0883-5403(06)80071-9","article-title":"Unrecognized femoral fractures during cementless total hip arthroplasty in the dog and their effect on bone ingrowth","volume":"7","author":"M Jasty","year":"1992","journal-title":"J Arthroplasty"},{"issue":"01","key":"ref27","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1111\/j.1532-950X.2011.00858.x","article-title":"Resistance to subsidence of an uncemented femoral stem after cerclage wiring of a fissure","volume":"41","author":"R S McCulloch","year":"2012","journal-title":"Vet Surg"},{"issue":"06","key":"ref28","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1016\/S0883-5403(05)80082-8","article-title":"Influence of intraoperative femoral fractures and cerclage wiring on bone ingrowth into canine porous-coated femoral components","volume":"10","author":"S F Schutzer","year":"1995","journal-title":"J Arthroplasty"},{"issue":"01","key":"ref29","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1302\/0301-620X.88B1.17029","article-title":"Risk factors for failure after treatment of a periprosthetic fracture of the femur","volume":"88","author":"H Lindahl","year":"2006","journal-title":"J Bone Joint Surg Br"},{"issue":"03","key":"ref30","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1055\/s-0038-1632994","article-title":"Complications and radiographic findings following cemented total hip replacement: a retrospective evaluation of 97 dogs","volume":"19","author":"M S Bergh","year":"2006","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"01","key":"ref31","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1186\/s12879-016-2063-4","article-title":"Antibiotics and antiseptics for preventing infection in people receiving revision total hip and knee prostheses: a systematic review of randomized controlled trials","volume":"16","author":"J Voigt","year":"2016","journal-title":"BMC Infect Dis"},{"issue":"06","key":"ref32","doi-asserted-by":"crossref","first-page":"424","DOI":"10.3415\/VCOT-09-07-0071","article-title":"Complications of cementless total hip replacement. A retrospective study of 163 cases","volume":"23","author":"D W Hummel","year":"2010","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"05","key":"ref33","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1111\/j.1532-950X.2012.01015.x","article-title":"Complications and owner assessment of canine total hip replacement: a multicenter internet based survey","volume":"41","author":"K E Forster","year":"2012","journal-title":"Vet Surg"},{"issue":"01","key":"ref34","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1053\/jvet.1999.0010","article-title":"Canine uncemented porous-coated anatomic total hip arthroplasty: results of a long-term prospective evaluation of 50 consecutive cases","volume":"28","author":"D J Marcellin-Little","year":"1999","journal-title":"Vet Surg"},{"issue":"02","key":"ref35","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1016\/j.injury.2017.11.010","article-title":"Closed incision negative pressure therapy decreases complications after periprosthetic fracture surgery around the hip and knee","volume":"49","author":"H J Cooper","year":"2018","journal-title":"Injury"},{"issue":"12","key":"ref36","doi-asserted-by":"crossref","first-page":"2295","DOI":"10.1016\/j.injury.2018.10.019","article-title":"Periprosthetic femoral nonunions treated with internal fixation and bone grafting","volume":"49","author":"J Prins","year":"2018","journal-title":"Injury"}],"container-title":["Veterinary and Comparative Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0040-1709486.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,15]],"date-time":"2020-09-15T22:34:31Z","timestamp":1600209271000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0040-1709486"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,30]]},"references-count":35,"journal-issue":{"issue":"05","published-online":{"date-parts":[[2020,9,15]]},"published-print":{"date-parts":[[2020,9]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0040-1709486","relation":{},"ISSN":["0932-0814","2567-6911"],"issn-type":[{"value":"0932-0814","type":"print"},{"value":"2567-6911","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,30]]}}}