{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T07:07:26Z","timestamp":1768720046903,"version":"3.49.0"},"reference-count":25,"publisher":"Georg Thieme Verlag KG","issue":"05","funder":[{"name":"Total Wagers tax"},{"name":"USDA-NIFA","award":["IND020784AH1"],"award-info":[{"award-number":["IND020784AH1"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet Comp Orthop Traumatol"],"published-print":{"date-parts":[[2020,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Objective\u2003The aim of this study was to determine how increasing stiffness of fracture site tissues distal to the pins in an equine distal limb transfixation cast influences stress at the bone\u2013pin interface, within the bones distal to the transcortical pins, and contact pressure between the foot and the cast.<\/jats:p><jats:p>Study Design\u2003A transfixation cast finite element model was used to compare the bone\u2013pin interface stress, pin stress, bone stress distal to the pins and contact pressure between the foot and the cast, using six stiffness values for a composite tissue block representing progressive stages of fracture healing.<\/jats:p><jats:p>Results\u2003Increasing stiffness of the composite tissue block resulted in a decrease in the maximum stresses at the bone\u2013pin interface, an increase in stresses distal to the transcortical pins and a decrease in the maximum pin stresses. As the composite tissue block stiffness was increased, contact pressure between the bottom of the composite tissue block and the cast increased and the stress patterns surrounding the pin holes became less focal.<\/jats:p><jats:p>Conclusion\u2003The findings of this study illustrate that with good foot to cast contact within a transfixation cast, increases in tissue stiffness due to progressive fracture healing are expected to reduce bone-pin interface stresses, and increase fracture site loading and stress. Increasing the contact pressure between the foot and the cast could reduce transfixation casting complications such as pin loosening, pin hole fracture and poor fracture healing, if these results transfer to ex vivo and in vivo settings.<\/jats:p>","DOI":"10.1055\/s-0040-1714353","type":"journal-article","created":{"date-parts":[[2020,8,14]],"date-time":"2020-08-14T23:27:55Z","timestamp":1597447675000},"page":"348-355","source":"Crossref","is-referenced-by-count":2,"title":["The Effect of Increasing Fracture Site Stiffness on Bone\u2013Pin Interface Stress and Foot Contact Pressure within the Equine Distal Limb Transfixation Cast: A Finite Element Analysis"],"prefix":"10.1055","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9475-4908","authenticated-orcid":false,"given":"Timothy B.","family":"Lescun","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Sciences (Lescun, Adams, Breur), College of Veterinary Medicine; and the Schools of Mechanical and Biomedical Engineering (Nauman), College of Engineering, Purdue University, West Lafayette, Indiana, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephen B.","family":"Adams","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Sciences (Lescun, Adams, Breur), College of Veterinary Medicine; and the Schools of Mechanical and Biomedical Engineering (Nauman), College of Engineering, Purdue University, West Lafayette, Indiana, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric A.","family":"Nauman","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Sciences (Lescun, Adams, Breur), College of Veterinary Medicine; and the Schools of Mechanical and Biomedical Engineering (Nauman), College of Engineering, Purdue University, West Lafayette, Indiana, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gert J.","family":"Breur","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Sciences (Lescun, Adams, Breur), College of Veterinary Medicine; and the Schools of Mechanical and Biomedical Engineering (Nauman), College of Engineering, Purdue University, West Lafayette, Indiana, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2020,8,14]]},"reference":[{"issue":"09","key":"ref1","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.2460\/ajvr.1998.59.09.1188","article-title":"Effect of three types of half-limb casts on in vitro bone strain recorded from the third metacarpal bone and proximal phalanx in equine cadaver limbs","volume":"59","author":"R K Schneider","year":"1998","journal-title":"Am J Vet Res"},{"issue":"02","key":"ref2","doi-asserted-by":"crossref","first-page":"254","DOI":"10.2460\/javma.2004.224.254","article-title":"Management of comminuted fractures of the proximal phalanx in horses: 64 cases (1983-2001)","volume":"224","author":"B M Kraus","year":"2004","journal-title":"J Am Vet Med Assoc"},{"issue":"05","key":"ref3","doi-asserted-by":"crossref","first-page":"725","DOI":"10.2460\/javma.229.5.725","article-title":"Use of transfixation pin casts to treat adult horses with comminuted phalangeal fractures: 20 cases (1993-2003)","volume":"229","author":"J Joyce","year":"2006","journal-title":"J Am Vet Med Assoc"},{"issue":"09","key":"ref4","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.2460\/javma.230.9.1340","article-title":"Evaluation of transfixation casting for treatment of third metacarpal, third metatarsal, and phalangeal fractures in horses: 37 cases (1994-2004)","volume":"230","author":"T B Lescun","year":"2007","journal-title":"J Am Vet Med Assoc"},{"key":"ref5","first-page":"1054","article-title":"Managing equine fractures with external skeletal fixation","volume":"17","author":"S McClure","year":"1995","journal-title":"Compend Contin Educ Pract Vet"},{"issue":"04","key":"ref6","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1111\/j.1532-950X.2014.12182.x","article-title":"Comparison of 2 equine transfixation pin casts and the effects of pin removal","volume":"43","author":"J M Williams","year":"2014","journal-title":"Vet Surg"},{"issue":"03","key":"ref7","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1002\/jor.1100030311","article-title":"Parametric analyses of pin-bone stresses in external fracture fixation devices","volume":"3","author":"R Huiskes","year":"1985","journal-title":"J Orthop Res"},{"issue":"01","key":"ref8","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1002\/jor.1100040108","article-title":"Guidelines for external fixation frame rigidity and stresses","volume":"4","author":"R Huiskes","year":"1986","journal-title":"J Orthop Res"},{"issue":"06","key":"ref9","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1002\/jor.1100080609","article-title":"A study of fracture callus material properties: relationship to the torsional strength of bone","volume":"8","author":"M D Markel","year":"1990","journal-title":"J Orthop Res"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1098\/rstb.1995.0031","article-title":"Experimentally determined microcracking around a circular hole in a flat plate of bone: comparison with predicted stresses","volume":"347","author":"P Zioupos","year":"1995","journal-title":"Philos Trans R Soc Lond B Biol Sci"},{"issue":"02","key":"ref11","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1016\/j.tvjl.2010.10.026","article-title":"Finite element analysis of a novel pin-sleeve system for external fixation of distal limb fractures in horses","volume":"190","author":"S Brianza","year":"2011","journal-title":"Vet J"},{"issue":"02","key":"ref12","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1016\/j.jbiomech.2007.09.009","article-title":"Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro","volume":"41","author":"E Schileo","year":"2008","journal-title":"J Biomech"},{"issue":"09","key":"ref13","doi-asserted-by":"crossref","first-page":"1754","DOI":"10.1016\/j.jbiomech.2010.02.021","article-title":"The compressive mechanical properties of diabetic and non-diabetic plantar soft tissue","volume":"43","author":"S Pai","year":"2010","journal-title":"J Biomech"},{"key":"ref14","first-page":"121","volume-title":"Chapter 4: Tissue Mechanics II Soft tissue. In: Orthopaedic Biomechanics: Mechanics and Design in Musculoskeletal Systems","author":"D L Bartel","year":"2006"},{"issue":"03","key":"ref15","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1111\/j.2042-3306.1998.tb04498.x","article-title":"Ex vivo simulation of in vivo strain distributions in the equine metacarpus","volume":"30","author":"C M Les","year":"1998","journal-title":"Equine Vet J"},{"issue":"02","key":"ref16","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.jbiomech.2004.12.002","article-title":"Osteonal effects on elastic modulus and fatigue life in equine bone","volume":"39","author":"V A Gibson","year":"2006","journal-title":"J Biomech"},{"issue":"05","key":"ref17","doi-asserted-by":"crossref","first-page":"752","DOI":"10.2460\/ajvr.2001.62.752","article-title":"Evaluation of dual energy x-ray absorptiometry for in situ measurement of bone mineral density of equine metacarpi","volume":"62","author":"S R McClure","year":"2001","journal-title":"Am J Vet Res"},{"issue":"06","key":"ref18","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1002\/jor.1100120610","article-title":"Estimation of material properties in the equine metacarpus with use of quantitative computed tomography","volume":"12","author":"C M Les","year":"1994","journal-title":"J Orthop Res"},{"issue":"07","key":"ref19","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1016\/S0021-9290(03)00071-X","article-title":"Trabecular bone modulus-density relationships depend on anatomic site","volume":"36","author":"E F Morgan","year":"2003","journal-title":"J Biomech"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.mser.2014.10.001","article-title":"Metallic implant biomaterials","volume":"87","author":"Q Chen","year":"2015","journal-title":"Mater Sci Eng Rep"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1007\/BF02719191","article-title":"Fatigue failures of austenitic stainless steel orthopedic fixation devices","volume":"2","author":"M Stevenson","year":"2002","journal-title":"Pract Fail Anal"},{"issue":"07","key":"ref22","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.2460\/ajvr.1996.57.07.1098","article-title":"In vitro evaluation of four methods of attaching transfixation pins into a fiberglass cast for use in horses","volume":"57","author":"S R McClure","year":"1996","journal-title":"Am J Vet Res"},{"issue":"01","key":"ref23","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1097\/00005131-198903010-00011","article-title":"Mechanical properties and material characteristics of orthopaedic casting material","volume":"3","author":"W M Mihalko","year":"1989","journal-title":"J Orthop Trauma"},{"issue":"01","key":"ref24","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1111\/j.1532-950X.2013.12075.x","article-title":"Use of a modified transfixation pin cast for treatment of comminuted phalangeal fractures in horses","volume":"43","author":"F Rossignol","year":"2014","journal-title":"Vet Surg"},{"issue":"05","key":"ref25","doi-asserted-by":"crossref","first-page":"724","DOI":"10.2460\/ajvr.73.5.724","article-title":"Comparison of hydroxyapatite-coated and uncoated pins for transfixation casting in horses","volume":"73","author":"T B Lescun","year":"2012","journal-title":"Am J Vet Res"}],"container-title":["Veterinary and Comparative Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0040-1714353.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,11]],"date-time":"2024-08-11T20:57:47Z","timestamp":1723409867000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0040-1714353"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,14]]},"references-count":25,"journal-issue":{"issue":"05","published-online":{"date-parts":[[2020,9,15]]},"published-print":{"date-parts":[[2020,9]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0040-1714353","relation":{},"ISSN":["0932-0814","2567-6911"],"issn-type":[{"value":"0932-0814","type":"print"},{"value":"2567-6911","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,14]]}}}