{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T00:05:19Z","timestamp":1782518719842,"version":"3.54.5"},"reference-count":24,"publisher":"Georg Thieme Verlag KG","issue":"01","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Neurol Surg A Cent Eur Neurosurg"],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Objective\u2003Ventriculoperitoneal shunt (VPS) placement is one of the most frequent neurosurgical procedures. The position of the proximal catheter is important for shunt survival. Shunt placement is done either without image guidance (\u201cfreehand\u201d) according to anatomical landmarks or by use of various image-guided techniques. Studies evaluating ultrasound-guided (US-G) VPS placement are sparse. We evaluate the accuracy and feasibility of US-G VPS placement, and compare it to freehand VPS placement.<\/jats:p><jats:p>\n          Methods\u2003We prospectively collected data of consecutive patients undergoing US-G VPS placement. Thereafter, the US cohort was compared with a cohort of patients in whom VPS was inserted using the freehand technique (freehand cohort). Primary outcome was accuracy of catheter positioning, and secondary outcomes were postoperative improvement in Evans' index (EI), rates of shunt dysfunction and revision surgery, perioperative complications, as well as operation, and anesthesia times.<\/jats:p><jats:p>\n          Results\u2003We included 15 patients undergoing US-G VPS insertion. Rates of optimally placed shunts were higher in the US cohort (67 vs. 49%, p\u2009=\u20090.28), whereas there were no malpositioned VPS (0%) in the US cohort, compared with 10 (5.8%) in the freehand cohort (p\u2009=\u20090.422). None of the factors in the univariate analysis showed significant association with nonoptimal (NOC) VPS placement in the US cohort. The mean EI improvement was significantly better in the US cohort than in the freehand cohort (0.043 vs. 0.014, p\u2009=\u20090.035).<\/jats:p><jats:p>\n          Conclusion\u2003Based on our preliminary results, US-G VPS placement seems to be feasible, safe, and increases the rate of optimally placed catheters.<\/jats:p>","DOI":"10.1055\/s-0040-1714388","type":"journal-article","created":{"date-parts":[[2020,9,24]],"date-time":"2020-09-24T01:52:15Z","timestamp":1600912335000},"page":"009-017","source":"Crossref","is-referenced-by-count":16,"title":["Ultrasound-Guided Insertion of the Ventricular Catheter in Ventriculoperitoneal Shunt Surgery: Evaluation of Accuracy and Feasibility in a Prospective Cohort"],"prefix":"10.1055","volume":"82","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2963-2891","authenticated-orcid":false,"given":"Severina","family":"Leu","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University Hospital Basel, Spitalstrasse 21, Basel 4031, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Kamenova","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University Hospital Basel, Spitalstrasse 21, Basel 4031, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luigi","family":"Mariani","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University Hospital Basel, Spitalstrasse 21, Basel 4031, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1900-9286","authenticated-orcid":false,"given":"Jehuda","family":"Soleman","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University Hospital Basel, Spitalstrasse 21, Basel 4031, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2020,9,23]]},"reference":[{"issue":"03","key":"ref1","doi-asserted-by":"crossref","first-page":"684","DOI":"10.3171\/2013.8.JNS13250","article-title":"Improvement in clinical outcomes following optimal targeting of brain ventricular catheters with intraoperative imaging","volume":"120","author":"C G Janson","year":"2014","journal-title":"J Neurosurg"},{"issue":"02","key":"ref2","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1159\/000333831","article-title":"Stereotactic placement of ventricular catheters: does it affect proximal malfunction rates?","volume":"90","author":"R Sampath","year":"2012","journal-title":"Stereotact Funct Neurosurg"},{"issue":"03","key":"ref3","doi-asserted-by":"crossref","first-page":"E12","DOI":"10.3171\/2015.12.FOCUS15583","article-title":"Optimizing ventriculoperitoneal shunt placement in the treatment of idiopathic intracranial hypertension: an analysis of neuroendoscopy, frameless stereotaxy, and intraoperative CT","volume":"40","author":"B Yim","year":"2016","journal-title":"Neurosurg Focus"},{"issue":"06","key":"ref4","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.3171\/2010.3.JNS091237","article-title":"Effect of electromagnetic-navigated shunt placement on failure rates: a prospective multicenter study","volume":"113","author":"C Hayhurst","year":"2010","journal-title":"J Neurosurg"},{"issue":"02","key":"ref5","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1159\/000271822","article-title":"CT-based, fiducial-free frameless stereotaxy for difficult ventriculoperitoneal shunt insertion: experience in 26 consecutive patients","volume":"88","author":"A S Reig","year":"2010","journal-title":"Stereotact Funct Neurosurg"},{"issue":"05","key":"ref6","doi-asserted-by":"crossref","first-page":"E5","DOI":"10.3171\/2017.7.FOCUS17148","article-title":"Real-time ultrasound-guided external ventricular drain placement: technical note","volume":"43","author":"J H Manfield","year":"2017","journal-title":"Neurosurg Focus"},{"issue":"01","key":"ref7","doi-asserted-by":"crossref","first-page":"66","DOI":"10.3171\/2012.11.JNS111384","article-title":"Comparison of the accuracy of ventricular catheter placement using freehand placement, ultrasonic guidance, and stereotactic neuronavigation","volume":"119","author":"T J Wilson","year":"2013","journal-title":"J Neurosurg"},{"issue":"03","key":"ref8","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1007\/s00381-017-3660-2","article-title":"Ultrasound-guided placement of ventricular catheters in first-time pediatric VP shunt surgery","volume":"34","author":"M Kullmann","year":"2018","journal-title":"Childs Nerv Syst"},{"issue":"02","key":"ref9","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.wneu.2013.01.039","article-title":"Intraoperative ultrasound guidance for the placement of permanent ventricular cerebrospinal fluid shunt catheters: a single-center historical cohort study","volume":"81","author":"R W Crowley","year":"2014","journal-title":"World Neurosurg"},{"issue":"06","key":"ref10","doi-asserted-by":"crossref","first-page":"e0198752","DOI":"10.1371\/journal.pone.0198752","article-title":"Yield of early postoperative computed tomography after frontal ventriculoperitoneal shunt placement","volume":"13","author":"M Kamenova","year":"2018","journal-title":"PLoS One"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1001\/archneurpsyc.1942.02290060069004","article-title":"An encephalographic ratio for estimating ventricular enlargement and cerebral atrophy","volume":"47","author":"W J Evans","year":"1942","journal-title":"Arch Neurol Psychiatry"},{"issue":"05","key":"ref12","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.3171\/2014.9.JNS132791","article-title":"Laparoscopically assisted ventriculoperitoneal shunt placement: a prospective randomized controlled trial","volume":"122","author":"P Schucht","year":"2015","journal-title":"J Neurosurg"},{"issue":"06","key":"ref14","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1097\/00006123-199912000-00012","article-title":"Change in ventricular size and effect of ventricular catheter placement in pediatric patients with shunted hydrocephalus","volume":"45","author":"S Tuli","year":"1999","journal-title":"Neurosurgery"},{"issue":"06","key":"ref15","doi-asserted-by":"crossref","first-page":"883","DOI":"10.3171\/jns.1988.69.6.0883","article-title":"Function of parietal and frontal shunts in childhood hydrocephalus","volume":"69","author":"A L Albright","year":"1988","journal-title":"J Neurosurg"},{"issue":"03","key":"ref16","doi-asserted-by":"crossref","first-page":"411","DOI":"10.3171\/jns.1982.56.3.0411","article-title":"Malfunctioning ventriculoperitoneal shunts. Clinical and pathological features","volume":"56","author":"L N Sekhar","year":"1982","journal-title":"J Neurosurg"},{"issue":"06","key":"ref17","doi-asserted-by":"crossref","first-page":"565","DOI":"10.3171\/2013.9.PEDS1346","article-title":"No significant improvement in the rate of accurate ventricular catheter location using ultrasound-guided CSF shunt insertion: a prospective, controlled study by the Hydrocephalus Clinical Research Network","volume":"12","author":"W E Whitehead","year":"2013","journal-title":"J Neurosurg Pediatr"},{"issue":"02","key":"ref18","doi-asserted-by":"crossref","first-page":"173","DOI":"10.3171\/2014.5.PEDS13481","article-title":"Factors associated with ventricular catheter movement and inaccurate catheter location: post hoc analysis of the hydrocephalus clinical research network ultrasound-guided shunt placement study","volume":"14","author":"W E Whitehead","year":"2014","journal-title":"J Neurosurg Pediatr"},{"issue":"05","key":"ref19","first-page":"406","article-title":"Accurate placement of cerebrospinal fluid shunt ventricular catheters with real-time ultrasound guidance in older children without patent fontanelles","volume":"107","author":"W E Whitehead","year":"2007","journal-title":"J Neurosurg"},{"issue":"02","key":"ref20","doi-asserted-by":"crossref","first-page":"157","DOI":"10.3171\/2016.8.PEDS16229","article-title":"Ventricular catheter entry site and not catheter tip location predicts shunt survival: a secondary analysis of 3 large pediatric hydrocephalus studies","volume":"19","author":"W E Whitehead","year":"2017","journal-title":"J Neurosurg Pediatr"},{"issue":"02","key":"ref21","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/S0090-3019(00)00267-6","article-title":"Ultrasound-based navigation during intracranial burr hole procedures: experience in a series of 100 cases","volume":"54","author":"M Strowitzki","year":"2000","journal-title":"Surg Neurol"},{"key":"ref22","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.jocn.2017.10.046","article-title":"The view through the ventricle catheter: the new ShuntScope for the therapy of pediatric hydrocephalus","volume":"48","author":"S Senger","year":"2018","journal-title":"J Clin Neurosci"},{"issue":"01","key":"ref23","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/s00381-012-1943-1","article-title":"Smartphone-assisted guide for the placement of ventricular catheters","volume":"29","author":"U W Thomale","year":"2013","journal-title":"Childs Nerv Syst"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1186\/1745-6215-14-428","article-title":"Guided Application of Ventricular Catheters (GAVCA): multicentre study to compare the ventricular catheter position after use of a catheter guide versus freehand application: study protocol for a randomised trial","volume":"14","author":"A Schaumann","year":"2013","journal-title":"Trials"},{"issue":"02","key":"ref25","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1093\/neuros\/nyx420","article-title":"GAVCA study: randomized, multicenter trial to evaluate the quality of ventricular catheter placement with a mobile health assisted guidance technique","volume":"83","author":"U W Thomale","year":"2018","journal-title":"Neurosurgery"}],"container-title":["Journal of Neurological Surgery Part A: Central European Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0040-1714388.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,6]],"date-time":"2021-01-06T23:33:02Z","timestamp":1609975982000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0040-1714388"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,23]]},"references-count":24,"journal-issue":{"issue":"01","published-online":{"date-parts":[[2021,1,6]]},"published-print":{"date-parts":[[2021,1]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0040-1714388","relation":{},"ISSN":["2193-6315","2193-6323"],"issn-type":[{"value":"2193-6315","type":"print"},{"value":"2193-6323","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,23]]}}}