{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T20:57:12Z","timestamp":1776459432483,"version":"3.51.2"},"reference-count":34,"publisher":"Georg Thieme Verlag KG","issue":"12","funder":[{"DOI":"10.13039\/501100022795","name":"Hamilton Health Sciences Foundation","doi-asserted-by":"crossref","award":["2019\u20132021"],"award-info":[{"award-number":["2019\u20132021"]}],"id":[{"id":"10.13039\/501100022795","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Perinatol"],"published-print":{"date-parts":[[2022,9]]},"abstract":"<jats:p>\n            Objective\u2003The study aimed to systematically review and analyze the impact of nasal intermittent positive pressure ventilation (NIPPV) versus continuous positive airway pressure (CPAP) on apnea of prematurity (AOP) in preterm neonates.<\/jats:p><jats:p>\n            Study Design\u2003In this systematic review and meta-analysis, experimental studies enrolling preterm infants comparing NIPPV (synchronized, nonsynchronized, and bi-level) and CPAP (all types) were searched in multiple databases and screened for the assessment of AOP. Primary outcome was AOP frequency per hour (as defined by authors of included studies).<\/jats:p><jats:p>\n            Results\u2003Out of 4,980 articles identified, 18 studies were included with eight studies contributing to the primary outcome. All studies had a high risk of bias, with significant heterogeneity in definition and measurement of AOP. There was no difference in AOPs per hour between NIPPV versus CPAP (weighted mean difference\u2009=\u2009\u22120.19; 95% confidence interval [CI]: \u22120.76 to 0.37; eight studies, 456 patients). However, in a post hoc analysis evaluating the presence of any AOP (over varying time periods), the pooled odds ratio (OR) was lower with NIPPV (OR: 0.46; 95% CI: 0.32\u20130.67; 10 studies, 872 patients).<\/jats:p><jats:p>\n            Conclusion\u2003NIPPV was not associated with decrease in AOP frequency, although demonstrated lower odds of developing any AOP. However, definite recommendations cannot be made based on the quality of the published evidence.<\/jats:p><jats:p>\n            Key Points\n          <\/jats:p>","DOI":"10.1055\/s-0040-1722337","type":"journal-article","created":{"date-parts":[[2021,1,16]],"date-time":"2021-01-16T00:02:11Z","timestamp":1610755331000},"page":"1314-1320","source":"Crossref","is-referenced-by-count":8,"title":["Nasal Intermittent Positive Pressure Ventilation versus Continuous Positive Airway Pressure and Apnea of Prematurity: A Systematic Review and Meta-Analysis"],"prefix":"10.1055","volume":"39","author":[{"given":"Bayane","family":"Sabsabi","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Division of Neonatology, McMaster University, Hamilton, Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ava","family":"Harrison","sequence":"additional","affiliation":[{"name":"Faculty of Health Sciences, McMaster University, Hamilton, Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Banfield","sequence":"additional","affiliation":[{"name":"Health Sciences Library, McMaster University, Hamilton, Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amit","family":"Mukerji","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Division of Neonatology, McMaster University, Hamilton, Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2021,1,15]]},"reference":[{"issue":"12","key":"ref1","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1038\/sj.jp.7211182","article-title":"Apnea is associated with neurodevelopmental impairment in very low birth weight infants","volume":"24","author":"A Janvier","year":"2004","journal-title":"J Perinatol"},{"issue":"03","key":"ref2","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1159\/000097446","article-title":"Factors influencing apnea and bradycardia of prematurity - implications for neurodevelopment","volume":"91","author":"F Pillekamp","year":"2007","journal-title":"Neonatology"},{"issue":"03","key":"ref3","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1159\/000329922","article-title":"Intermittent hypoxic episodes in preterm infants: do they matter?","volume":"100","author":"R J Martin","year":"2011","journal-title":"Neonatology"},{"issue":"02","key":"ref4","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1523\/JNEUROSCI.22-02-00455.2002","article-title":"Selective vulnerability of late oligodendrocyte progenitors to hypoxia-ischemia","volume":"22","author":"S A Back","year":"2002","journal-title":"J Neurosci"},{"issue":"07","key":"ref5","doi-asserted-by":"crossref","first-page":"1723","DOI":"10.1164\/ajrccm.163.7.2011060","article-title":"Bronchopulmonary dysplasia","volume":"163","author":"A H Jobe","year":"2001","journal-title":"Am J Respir Crit Care Med"},{"issue":"06","key":"ref6","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1016\/j.jpeds.2005.01.047","article-title":"Extremely low birthweight neonates with protracted ventilation: mortality and 18-month neurodevelopmental outcomes","volume":"146","author":"M C Walsh","year":"2005","journal-title":"J Pediatr"},{"issue":"07","key":"ref7","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1056\/NEJMoa072788","article-title":"Nasal CPAP or intubation at birth for very preterm infants","volume":"358","author":"C J Morley","year":"2008","journal-title":"N Engl J Med"},{"issue":"01","key":"ref8","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.clp.2007.11.004","article-title":"Pulmonary complications of mechanical ventilation in neonates","volume":"35","author":"J D Miller","year":"2008","journal-title":"Clin Perinatol"},{"issue":"21","key":"ref9","doi-asserted-by":"crossref","first-page":"1970","DOI":"10.1056\/NEJMoa0911783","article-title":"Early CPAP versus surfactant in extremely preterm infants","volume":"362","author":"N N Finer","year":"2010","journal-title":"N Engl J Med"},{"issue":"03","key":"ref10","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.prrv.2010.12.001","article-title":"Current methods of non-invasive ventilatory support for neonates","volume":"12","author":"R A Mahmoud","year":"2011","journal-title":"Paediatr Respir Rev"},{"issue":"10","key":"ref11","first-page":"1196","article-title":"Nasal intermittent positive-pressure ventilation offers no advantages over nasal continuous positive airway pressure in apnea of prematurity","volume":"143","author":"C A Ryan","year":"1989","journal-title":"Am J Dis Child"},{"issue":"05","key":"ref12","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1002\/(SICI)1099-0496(199811)26:5<349::AID-PPUL8>3.0.CO;2-7","article-title":"Efficacy of nasal intermittent positive pressure ventilation in treating apnea of prematurity","volume":"26","author":"C H Lin","year":"1998","journal-title":"Pediatr Pulmonol"},{"issue":"01","key":"ref13","first-page":"CD002272","article-title":"Nasal intermittent positive pressure ventilation (NIPPV) versus nasal continuous positive airway pressure (NCPAP) for apnea of prematurity","author":"B Lemyre","year":"2002","journal-title":"Cochrane Database Syst Rev"},{"issue":"04","key":"ref14","doi-asserted-by":"crossref","first-page":"F245","DOI":"10.1136\/adc.2008.148981","article-title":"Randomised crossover trial of four nasal respiratory support systems for apnoea of prematurity in very low birthweight infants","volume":"94","author":"T Pantalitschka","year":"2009","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"issue":"02","key":"ref15","first-page":"91","article-title":"A comparison of nasal intermittent versus continuous positive pressure delivery for the treatment of moderate respiratory syndrome in preterm infants","volume":"59","author":"M Bisceglia","year":"2007","journal-title":"Minerva Pediatr"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"b2535","DOI":"10.1136\/bmj.b2535","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement","volume":"339","author":"D Moher","year":"2009","journal-title":"BMJ"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"d5928","DOI":"10.1136\/bmj.d5928","article-title":"The Cochrane Collaboration's tool for assessing risk of bias in randomised trials","volume":"343","author":"J P Higgins","year":"2011","journal-title":"BMJ"},{"issue":"04","key":"ref19","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1542\/peds.107.4.638","article-title":"Randomized trial of nasal synchronized intermittent mandatory ventilation compared with continuous positive airway pressure after extubation of very low birth weight infants","volume":"107","author":"K J Barrington","year":"2001","journal-title":"Pediatrics"},{"issue":"01","key":"ref20","doi-asserted-by":"crossref","first-page":"F17","DOI":"10.1136\/archdischild-2013-305892","article-title":"Is synchronised NIPPV more effective than NIPPV and NCPAP in treating apnoea of prematurity (AOP)? A randomised cross-over trial","volume":"100","author":"C Gizzi","year":"2015","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"issue":"01","key":"ref21","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1542\/peds.108.1.13","article-title":"A prospective randomized, controlled trial comparing synchronized nasal intermittent positive pressure ventilation versus nasal continuous positive airway pressure as modes of extubation","volume":"108","author":"M N Khalaf","year":"2001","journal-title":"Pediatrics"},{"issue":"01","key":"ref22","doi-asserted-by":"crossref","first-page":"F31","DOI":"10.1136\/fetalneonatal-2013-305665","article-title":"Bi-level CPAP does not improve gas exchange when compared with conventional CPAP for the treatment of neonates recovering from respiratory distress syndrome","volume":"100","author":"A L Lampland","year":"2015","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"issue":"06","key":"ref23","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1111\/ped.12854","article-title":"Effects of infant flow Bi-NCPAP on apnea of prematurity","volume":"58","author":"C Ishihara","year":"2016","journal-title":"Pediatr Int (Roma)"},{"issue":"S 03","key":"ref24","first-page":"S136","article-title":"A randomized trial of non-synchronized nasopharyngeal intermittent mandatory ventilation (nsNIMV) vs. nasal continuous positive airway pressure (NCPAP) in the prevention of extubation failure in pre-term < 1,500 grams","volume":"91","author":"M Khorana","year":"2008","journal-title":"J Med Assoc Thai"},{"issue":"01","key":"ref25","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1111\/j.1442-200X.2007.02525.x","article-title":"Nasal flow-synchronized intermittent positive pressure ventilation to facilitate weaning in very low-birthweight infants: unmasked randomized controlled trial","volume":"50","author":"C Moretti","year":"2008","journal-title":"Pediatr Int"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/1471-2431-12-43","article-title":"Infant flow biphasic nasal continuous positive airway pressure (BP- NCPAP) vs. infant flow NCPAP for the facilitation of extubation in infants' \u2264 1,250 grams: a randomized controlled trial","volume":"12","author":"K O'Brien","year":"2012","journal-title":"BMC Pediatr"},{"issue":"02","key":"ref27","first-page":"197","article-title":"Nasal-imv versus nasal-CPAP as an initial mode of respiratory support for premature infants with RDS: a prospective randomized clinical trial","volume":"40","author":"G SA Salama","year":"2015","journal-title":"Rawal Med J"},{"issue":"12","key":"ref28","doi-asserted-by":"crossref","first-page":"1772","DOI":"10.4187\/respcare.03565","article-title":"Response of preterm infants to 2 noninvasive ventilatory support systems: Nasal CPAP and nasal intermittent positive-pressure ventilation","volume":"60","author":"C ST Silveira","year":"2015","journal-title":"Respir Care"},{"issue":"04","key":"ref29","first-page":"573","article-title":"Usefulness of DuoPAP in the treatment of very low birth weight preterm infants with neonatal respiratory distress syndrome","volume":"19","author":"B Zhou","year":"2015","journal-title":"Eur Rev Med Pharmacol Sci"},{"issue":"04","key":"ref30","first-page":"1","article-title":"A comparison between nasal intermittent positive pressure ventilation and nasal continuous positive airway pressure ventilation in the treatment of neonatal respiratory distress syndrome","volume":"6","author":"A S Farhat","year":"2015","journal-title":"Iran J Neonatol"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"21","DOI":"10.4103\/2008-7802.173930","article-title":"A comparison of the effect of nasal bi-level positive airway pressure and sigh-positive airway pressure on the treatment of the preterm newborns weighing less than 1500\u2009g affiliated with respiratory distress syndrome","volume":"7","author":"A Sadeghnia","year":"2016","journal-title":"Int J Prev Med"},{"issue":"02","key":"ref32","first-page":"e2352","article-title":"Comparison of complications and efficacy of NIPPV and nasal CPAP in preterm infants with RDS","volume":"26","author":"T Esmaeilnia","year":"2016","journal-title":"Iran J Pediatr"},{"issue":"06","key":"ref33","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1590\/1806-9282.62.06.568","article-title":"Randomized controlled trial comparing nasal intermittent positive pressure ventilation and nasal continuous positive airway pressure in premature infants after tracheal extubation","volume":"62","author":"D FR Komatsu","year":"2016","journal-title":"Rev Assoc Med Bras"},{"issue":"03","key":"ref34","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.siny.2016.01.003","article-title":"Nasal intermittent positive pressure ventilation in preterm infants: Equipment, evidence, and synchronization","volume":"21","author":"L S Owen","year":"2016","journal-title":"Semin Fetal Neonatal Med"},{"issue":"09","key":"ref35","doi-asserted-by":"crossref","first-page":"1412","DOI":"10.1111\/j.1651-2227.2009.01348.x","article-title":"Early nasal intermittent positive pressure ventilation versus continuous positive airway pressure for respiratory distress syndrome","volume":"98","author":"M Sai Sunil Kishore","year":"2009","journal-title":"Acta Paediatr"}],"container-title":["American Journal of Perinatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0040-1722337.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,31]],"date-time":"2022-08-31T23:26:52Z","timestamp":1661988412000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0040-1722337"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,15]]},"references-count":34,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2022,8,31]]},"published-print":{"date-parts":[[2022,9]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0040-1722337","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0735-1631","1098-8785"],"issn-type":[{"value":"0735-1631","type":"print"},{"value":"1098-8785","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,15]]}}}