{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T12:45:59Z","timestamp":1790858759815,"version":"4.1.0"},"reference-count":37,"publisher":"Georg Thieme Verlag KG","issue":"14","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Knee Surg"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Advanced imaging used in robotic-assisted total knee arthroplasty (TKA), such as computed tomography (CT)-based three-dimensional (3D) planning, may provide an accurate means of implant sizing preoperatively. The purpose of this study was to examine preoperative CT-based implant planning accuracy for robotic-assisted TKA in patients who have (1) varus deformities, (2) valgus deformities, (3) neutral alignment, and (4) retained hardware. A total of 393 patients underwent a robotic-assisted TKA by a single surgeon received preoperative CT scans. The surgeon reviewed the CT-based model preoperatively and recorded the expected size of the components. The final implants used in each case were recorded and compared with the surgeon's preoperative plan. In all groups of patients, the surgeon's CT-based implant plan was within one size of the implant utilized 100% of the time for both the tibiae and femora. Overall, the surgeon was exactly matched in 319 (81%) and 315 (80%) cases for the femoral and tibial components, respectively. For the femoral component, the mean age for patients in whom the original plan was exactly matched was younger than those whose implants were upsized and older than patients those implants were downsized (p\u2009=\u20090.024). Other patient demographics and preoperative knee alignment were not associated with predictive accuracy for femoral or tibial components. Our results demonstrate how preoperative CT-based, 3D planning for robotic-assisted TKA is accurate to within one size of the components in every case (100%), and exactly matched in 80%. The results of this study are important because they demonstrate how CT-based preoperative implant planning for TKA is reliable and accurate across all native knee alignments and other patient-specific factors. In addition, they build on a previous study by the same single surgeon, demonstrating that predictive ability can improve over time. This may be important as we move toward more outpatient surgery with less ability for prostheses inventory at ambulatory sites.<\/jats:p>","DOI":"10.1055\/s-0041-1729548","type":"journal-article","created":{"date-parts":[[2021,5,1]],"date-time":"2021-05-01T22:35:16Z","timestamp":1619908516000},"page":"1587-1594","source":"Crossref","is-referenced-by-count":9,"title":["The Accuracy of Computed Tomography-Based, Three-Dimensional Implant Planning in Robotic-Assisted Total Knee Arthroplasty"],"prefix":"10.1055","volume":"35","author":[{"given":"Kevin B.","family":"Marchand","sequence":"additional","affiliation":[{"name":"Northwell Health Orthopaedics, Lenox Hill Hospital, New York, New York"},{"name":"CUNY School of Medicine, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hytham S.","family":"Salem","sequence":"additional","affiliation":[{"name":"Northwell Health Orthopaedics, Lenox Hill Hospital, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin K.","family":"Mathew","sequence":"additional","affiliation":[{"name":"Northwell Health Orthopaedics, Lenox Hill Hospital, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven F.","family":"Harwin","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Mount Sinai West New York, Manhattan New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael A.","family":"Mont","sequence":"additional","affiliation":[{"name":"Northwell Health Orthopaedics, Lenox Hill Hospital, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert C.","family":"Marchand","sequence":"additional","affiliation":[{"name":"South County Orthopedics, Orthopedics Rhode Island, Wakefield, Rhode Island"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2021,5,1]]},"reference":[{"issue":"07","key":"ref1","doi-asserted-by":"crossref","first-page":"2002","DOI":"10.1016\/j.arth.2018.01.060","article-title":"Robotic arm-assisted total knee arthroplasty","volume":"33","author":"A Khlopas","year":"2018","journal-title":"J Arthroplasty"},{"issue":"08","key":"ref2","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1055\/s-0038-1668122","article-title":"Does the robotic arm and preoperative CT planning help with 3D intraoperative total knee arthroplasty planning?","volume":"32","author":"C Condrey","year":"2019","journal-title":"J Knee Surg"},{"issue":"10","key":"ref3","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1302\/2058-5241.4.190022","article-title":"Robotic technology in total knee arthroplasty: a systematic review","volume":"4","author":"B Kayani","year":"2019","journal-title":"EFORT Open Rev"},{"issue":"01","key":"ref4","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1586\/17434440.2016.1124018","article-title":"Robot-assisted total hip arthroplasty","volume":"13","author":"S Banerjee","year":"2016","journal-title":"Expert Rev Med Devices"},{"issue":"10","key":"ref5","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1302\/0301-620X.100B10-BJJ-2018-0201.R1","article-title":"Intraoperative placement of total hip arthroplasty components with robotic-arm assisted technology correlates with postoperative implant position: a CT-based study","volume":"100-B","author":"S R Nodzo","year":"2018","journal-title":"Bone Joint J"},{"issue":"10","key":"ref6","doi-asserted-by":"crossref","first-page":"2353","DOI":"10.1016\/j.arth.2016.05.026","article-title":"Robotics in arthroplasty: a comprehensive review","volume":"31","author":"D J Jacofsky","year":"2016","journal-title":"J Arthroplasty"},{"issue":"09","key":"ref7","doi-asserted-by":"crossref","first-page":"2663","DOI":"10.1016\/j.arth.2017.03.066","article-title":"Current epidemiology of revision total knee arthroplasty in the United States","volume":"32","author":"R E Delanois","year":"2017","journal-title":"J Arthroplasty"},{"issue":"04","key":"ref8","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1055\/s-0038-1667118","article-title":"Assessment of loosening and rotational malalignment following knee endoprosthesis or other surgical components","volume":"22","author":"I N Gemescu","year":"2018","journal-title":"Semin Musculoskelet Radiol"},{"issue":"06","key":"ref9","doi-asserted-by":"crossref","first-page":"436","DOI":"10.5435\/00124635-200411000-00008","article-title":"The failed total knee arthroplasty: evaluation and etiology","volume":"12","author":"M H Gonzalez","year":"2004","journal-title":"J Am Acad Orthop Surg"},{"issue":"03","key":"ref10","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1055\/s-0038-1641729","article-title":"Robotic-arm assisted total knee arthroplasty demonstrated greater accuracy and precision to plan compared with manual techniques","volume":"32","author":"E L Hampp","year":"2019","journal-title":"J Knee Surg"},{"issue":"02","key":"ref11","doi-asserted-by":"crossref","first-page":"86","DOI":"10.3109\/10929088.2012.654408","article-title":"Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment","volume":"17","author":"Y W Moon","year":"2012","journal-title":"Comput Aided Surg"},{"issue":"09","key":"ref12","first-page":"e1334","article-title":"Robot-assisted implantation improves the precision of component position in minimally invasive TKA","volume":"35","author":"S-M Kim","year":"2012","journal-title":"Orthopedics"},{"issue":"10","key":"ref13","doi-asserted-by":"crossref","first-page":"529","DOI":"10.11622\/smedj.2014136","article-title":"Early experiences with robot-assisted total knee arthroplasty using the DigiMatch ROBODOC surgical system","volume":"55","author":"M HL Liow","year":"2014","journal-title":"Singapore Med J"},{"issue":"04","key":"ref14","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.surge.2017.12.003","article-title":"Increased precision of coronal plane outcomes in robotic-assisted total knee arthroplasty: a systematic review and meta-analysis","volume":"16","author":"A Mannan","year":"2018","journal-title":"Surgeon"},{"issue":"212","key":"ref15","first-page":"2","article-title":"Accuracy of bone resection in MAKO total knee robotic-assisted surgery","volume":"1","author":"J D Sires","year":"2019","journal-title":"J Knee Surg"},{"key":"ref16","first-page":"441","article-title":"Robotic-arm assisted total knee arthroplasty demonstrated soft tissue protection","volume":"30","author":"A Khlopas","year":"2017","journal-title":"Surg Technol Int"},{"issue":"12","key":"ref17","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1080\/17434440.2017.1392237","article-title":"Utilization of robotic-arm assisted total knee arthroplasty for soft tissue protection","volume":"14","author":"A A Sultan","year":"2017","journal-title":"Expert Rev Med Devices"},{"issue":"01","key":"ref18","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1055\/s-0037-1608840","article-title":"Coronal correction for severe deformity using robotic-assisted total knee arthroplasty","volume":"31","author":"R C Marchand","year":"2018","journal-title":"J Knee Surg"},{"issue":"01","key":"ref19","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1055\/s-0037-1608839","article-title":"Difficult cases in robotic arm-assisted total knee arthroplasty: a case series","volume":"31","author":"R C Marchand","year":"2018","journal-title":"J Knee Surg"},{"key":"ref20","first-page":"497","article-title":"Robotic-assisted total knee arthroplasty in the presence of extra-articular deformity","volume":"34","author":"N Sodhi","year":"2019","journal-title":"Surg Technol Int"},{"issue":"03","key":"ref21","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/S0968-0160(02)00015-7","article-title":"Technique and first clinical results of robot-assisted total knee replacement","volume":"9","author":"W Siebert","year":"2002","journal-title":"Knee"},{"issue":"07","key":"ref22","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1055\/s-0039-1684014","article-title":"Patient-reported functional and satisfaction outcomes after robotic-arm-assisted total knee arthroplasty: early results of a prospective multicenter investigation","volume":"33","author":"A Khlopas","year":"2020","journal-title":"J Knee Surg"},{"issue":"07","key":"ref23","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1302\/0301-620X.100B7.BJJ-2017-1449.R1","article-title":"Robotic-arm assisted total knee arthroplasty is associated with improved early functional recovery and reduced time to hospital discharge compared with conventional jig-based total knee arthroplasty: a prospective cohort study","volume":"100-B","author":"B Kayani","year":"2018","journal-title":"Bone Joint J"},{"issue":"04","key":"ref24","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1016\/j.artd.2019.04.007","article-title":"Robotic arm assisted total knee arthroplasty workflow optimization, operative times and learning curve","volume":"5","author":"L Grau","year":"2019","journal-title":"Arthroplast Today"},{"issue":"04","key":"ref25","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1007\/s00167-018-5138-5","article-title":"Robotic-arm assisted total knee arthroplasty has a learning curve of seven cases for integration into the surgical workflow but no learning curve effect for accuracy of implant positioning","volume":"27","author":"B Kayani","year":"2019","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"07","key":"ref26","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1055\/s-0038-1666829","article-title":"Preoperative CT-based three-dimensional templating in robot-assisted total knee arthroplasty more accurately predicts implant sizes than two-dimensional templating","volume":"32","author":"J RT Pietrzak","year":"2019","journal-title":"J Knee Surg"},{"issue":"10","key":"ref27","doi-asserted-by":"crossref","first-page":"1699","DOI":"10.1016\/j.arth.2015.04.043","article-title":"Template-directed instrumentation reduces cost and improves efficiency for total knee arthroplasty: an economic decision analysis and pilot study","volume":"30","author":"A S McLawhorn","year":"2015","journal-title":"J Arthroplasty"},{"issue":"11","key":"ref28","first-page":"e1596","article-title":"Template-directed instrumentation in total knee arthroplasty: cost savings analysis","volume":"35","author":"A R Hsu","year":"2012","journal-title":"Orthopedics"},{"issue":"02","key":"ref29","first-page":"e179","article-title":"Effect of training level on accuracy of digital templating in primary total hip and knee arthroplasty","volume":"35","author":"A R Hsu","year":"2012","journal-title":"Orthopedics"},{"issue":"01","key":"ref30","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1080\/00016470510030364","article-title":"Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees","volume":"76","author":"B The","year":"2005","journal-title":"Acta Orthop"},{"issue":"06","key":"ref31","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/j.knee.2006.05.002","article-title":"The role of preoperative templating in total knee arthroplasty: comparison of three prostheses","volume":"13","author":"D WJ Howcroft","year":"2006","journal-title":"Knee"},{"issue":"01","key":"ref32","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1055\/s-0037-1608809","article-title":"The learning curve associated with robotic total knee arthroplasty","volume":"31","author":"N Sodhi","year":"2018","journal-title":"J Knee Surg"},{"issue":"04","key":"ref33","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1302\/0301-620X.97B4.33740","article-title":"The dynamic nature of alignment and variations in normal knees","volume":"97-B","author":"K Deep","year":"2015","journal-title":"Bone Joint J"},{"issue":"12","key":"ref34","doi-asserted-by":"crossref","first-page":"2271","DOI":"10.1016\/j.arth.2015.05.037","article-title":"Cost analysis and surgical site infection rates in total knee arthroplasty comparing traditional vs. single-use instrumentation","volume":"30","author":"G W Siegel","year":"2015","journal-title":"J Arthroplasty"},{"issue":"12","key":"ref35","doi-asserted-by":"crossref","first-page":"865","DOI":"10.5435\/JAAOS-D-15-00751","article-title":"Cost savings from utilization of an ambulatory surgery center for orthopaedic day surgery","volume":"24","author":"P D Fabricant","year":"2016","journal-title":"J Am Acad Orthop Surg"},{"key":"ref36","first-page":"113","volume-title":"Lean management: inventory, waste management","author":"A Elsharydah","year":"2020"},{"issue":"01","key":"ref37","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.jajs.2016.01.001","article-title":"Comparison of CT-based patient-specific templating and digital radiography templating in total knee arthroplasty","volume":"3","author":"R R Gandhi","year":"2016","journal-title":"J Arthrosc Jt Surg"}],"container-title":["The Journal of Knee Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0041-1729548.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,21]],"date-time":"2022-12-21T01:16:38Z","timestamp":1671585398000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0041-1729548"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,1]]},"references-count":37,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2022,12,20]]},"published-print":{"date-parts":[[2022,12]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0041-1729548","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["1538-8506","1938-2480"],"issn-type":[{"value":"1538-8506","type":"print"},{"value":"1938-2480","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,1]]}}}